a3ComPortDialBODTHreshold

A3Com-PortPath-r6-MIB · .1.3.6.1.4.1.43.2.19.2.1.15

Object

column mandatory r/w Integer32
%BODTHreshold% This object specifies the level of sensitivity to 
bring up a BOD path for a port. The larger BODTHreshold value, the
less sensitive to bring up BOD path. 
For DOD port, when the BODTHreshold is set to 0, the BOD path and the
primary path are treated as one path. The port will bring the two
paths up and down together.
              
Note, when this parameter is enabled/disabled, the port itself
must be disabled and then re-enabled for the new value to take
effect.  This is done by setting the cirresponding instance of
ifAdminStatus to up(1).

Context

MIB
A3Com-PortPath-r6-MIB
OID
.1.3.6.1.4.1.43.2.19.2.1.15
Type
column
Access
readwrite
Status
mandatory
Parent
a3ComPortDialEntry
Table
a3ComPortDialTable
Siblings
14

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-100

Related Objects

Sibling Objects