ZYXEL-accessSwitch-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
7
Rows
7
Columns
31
.1.3.6.1.4.1.890.1.5.1.1.4 · 1 row entry · 6 columns
A table that contains rpm information about the fans.
accessSwitchFanRpmEntry entry .1.3.6.1.4.1.890.1.5.1.1.4.1
A list of rpm information for each fan.
Indexes
accessSwitchFanRpmIndex
Column Syntax OID
accessSwitchFanRpmIndex mandatory
The identity of the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.1
accessSwitchFanRpmCurValue mandatory
The current rpm of the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.2
accessSwitchFanRpmMaxValue mandatory
The maximum rpm ever performed by the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.3
accessSwitchFanRpmMinValue mandatory
The minimum rpm ever performed by the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.4
accessSwitchFanRpmLowThresh mandatory
The low threshold of the rpm of the fan. If the current rpm is less than
the threshold, the device will initiate the fanRpmLow trap.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.5
accessSwitchFanRpmDescr mandatory
The description of the fan (e.g. location, function, etc.).
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.4.1.6
.1.3.6.1.4.1.890.1.5.1.1.5 · 1 row entry · 7 columns
A table that contains voltage information about the system.
accessSwitchVoltageEntry entry .1.3.6.1.4.1.890.1.5.1.1.5.1
A list of voltage information for each sensor.
Indexes
accessSwitchVoltageIndex
Column Syntax OID
accessSwitchVoltageIndex mandatory
The identity of the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.1
accessSwitchVoltageCurValue mandatory
The current voltage detected by the sensor (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.2
accessSwitchVoltageMaxValue mandatory
The maximum voltage ever detected by the sensor (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.3
accessSwitchVoltageMinValue mandatory
The minimum voltage ever detected by the sensor (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.4
accessSwitchVoltageNominalValue mandatory
The nominal voltage which the power should supply (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.5
accessSwitchVoltageLowThresh mandatory
The low threshold of the voltage. If the current voltage is less than
the threshold, the device will initiate the voltageLow trap.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.6
accessSwitchVoltageDescr mandatory
The description of the voltage (e.g. location, nominal value, etc.).
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.5.1.7
.1.3.6.1.4.1.890.1.5.1.1.6 · 1 row entry · 6 columns
A table that contains temperature information about system.
accessSwitchSysTempEntry entry .1.3.6.1.4.1.890.1.5.1.1.6.1
A list of temperature information for each sensor.
Indexes
accessSwitchSysTempIndex
Column Syntax OID
accessSwitchSysTempIndex mandatory
The identity of the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.1
accessSwitchSysTempCurValue mandatory
The current temperature detected in Celsius by the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.2
accessSwitchSysTempMaxValue mandatory
The maximum temperature ever detected in Celsius by the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.3
accessSwitchSysTempMinValue mandatory
The minimum temperature ever detected in Celsius by the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.4
accessSwitchSysTempHighThresh mandatory
The high threshold of the temperature in Celsius. If the current temperature
is higher than the threshold, the device will initiate the overheat trap.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.5
accessSwitchSysTempDescr mandatory
The description of the temperature sensor (e.g. location, function, etc.).
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.6.1.6
.1.3.6.1.4.1.890.1.5.1.1.20 · 1 row entry · 1 columns
This table includes the configuration of packet forwarding.
asPacketForwardingEntry entry .1.3.6.1.4.1.890.1.5.1.1.20.1
An entry in asPacketForwardingTable.
Indexes
Column Syntax OID
asPacketForwardingPortList mandatory
The list defines the ports to which the packets
will be forwarded.
Q-BRIDGE-MIBPortListr/w
Textual Convention: Q-BRIDGE-MIBPortList OctetString
.1.3.6.1.4.1.890.1.5.1.1.20.1.1

asDhcpServerTable

table mandatory
.1.3.6.1.4.1.890.1.5.1.1.25 · 1 row entry · 2 columns
A table that contains DHCP server information.
asDhcpServerEntry entry .1.3.6.1.4.1.890.1.5.1.1.25.1
The entry of DHCP server table.
Indexes
asDhcpServerIp
Column Syntax OID
asDhcpServerIp mandatory
The IP address of the DHCP server.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.890.1.5.1.1.25.1.1
asDhcpServerRowStatus mandatory
The row status of the DHCP server entry.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.890.1.5.1.1.25.1.2

asRadiusServerTable

table mandatory
.1.3.6.1.4.1.890.1.5.1.1.29 · 1 row entry · 5 columns
A table that contains Radius Server information.
asRadiusServerEntry entry .1.3.6.1.4.1.890.1.5.1.1.29.1
The entry of Radius Server table.
Indexes
asRadiusServerIndex
Column Syntax OID
asRadiusServerIndex mandatory
The identity of the RADIUS server.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.29.1.1
asRadiusServerIp mandatory
The IP address of the Radius Server.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.890.1.5.1.1.29.1.2
asRadiusServerPort mandatory
The UDP port of the Radius Server.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.29.1.3
asRadiusSharedSecret mandatory
The shared secret of the Radius Server.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.29.1.4
asRadiusServerRowStatus mandatory
The row status of the Radius Server entry.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.890.1.5.1.1.29.1.5

asDot1xPortTable

table mandatory
.1.3.6.1.4.1.890.1.5.1.1.31 · 1 row entry · 4 columns
This table includes the configuration of 802.1x.
asDot1xPortEntry entry .1.3.6.1.4.1.890.1.5.1.1.31.1
An entry in asDot1xPortTable.
Indexes
Column Syntax OID
asDot1xPortEnable mandatory
The option defines if the port enables 802.1x
settings.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.890.1.5.1.1.31.1.1
asDot1xPortControl mandatory
The configuration defines the 802.1x port control
type.
Enumerationr/w
Enumerated Values:
1auto
2forceAuth
3forceUnAuth
.1.3.6.1.4.1.890.1.5.1.1.31.1.2
asDot1xPortReAuthEnable mandatory
The option defines if the port enables 802.1x
re-authentication.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.890.1.5.1.1.31.1.3
asDot1xPortReAuthPeriod mandatory
The configuration defines the 802.1x
re-authentication period for each port.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.31.1.4