ZYXEL-AS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
8
Rows
8
Columns
34
.1.3.6.1.4.1.890.1.5.1.1.4 · 1 row entry · 6 columns
A table that contains rpm information about the fans.
accessSwitchFanRpmEntry entry .1.3.6.1.4.1.890.1.5.1.1.4.1
A list of rpm information for each fan.
Indexes
accessSwitchFanRpmIndex
Column Syntax OID
accessSwitchFanRpmIndex
The identity of the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.1
accessSwitchFanRpmCurValue
The current rpm of the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.2
accessSwitchFanRpmMaxValue
The maximum rpm ever performed by the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.3
accessSwitchFanRpmMinValue
The minimum rpm ever performed by the fan.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.4
accessSwitchFanRpmLowThresh
The low threshold of the rpm of the fan. If the current rpm is less than
the threshold, the device will initiate the fanRpmLow trap.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.4.1.5
accessSwitchFanRpmDescr
The description of the fan (e.g. location, function, etc.).
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.4.1.6
.1.3.6.1.4.1.890.1.5.1.1.5 · 1 row entry · 7 columns
A table that contains voltage information about the system.
accessSwitchVoltageEntry entry .1.3.6.1.4.1.890.1.5.1.1.5.1
A list of voltage information for each sensor.
Indexes
accessSwitchVoltageIndex
Column Syntax OID
accessSwitchVoltageIndex
The identity of the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.1
accessSwitchVoltageCurValue
The current voltage detected by the sensor (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.2
accessSwitchVoltageMaxValue
The maximum voltage ever detected by the sensor (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.3
accessSwitchVoltageMinValue
The minimum voltage ever detected by the sensor (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.4
accessSwitchVoltageNominalValue
The nominal voltage which the power should supply (in milli-voltage).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.5
accessSwitchVoltageLowThresh
The low threshold of the voltage. If the current voltage is less than
the threshold, the device will initiate the voltageLow trap.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.5.1.6
accessSwitchVoltageDescr
The description of the voltage (e.g. location, nominal value, etc.).
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.5.1.7
.1.3.6.1.4.1.890.1.5.1.1.6 · 1 row entry · 6 columns
A table that contains temperature information about system.
accessSwitchSysTempEntry entry .1.3.6.1.4.1.890.1.5.1.1.6.1
A list of temperature information for each sensor.
Indexes
accessSwitchSysTempIndex
Column Syntax OID
accessSwitchSysTempIndex
The identity of the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.1
accessSwitchSysTempCurValue
The current temperature detected in Celsius by the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.2
accessSwitchSysTempMaxValue
The maximum temperature ever detected in Celsius by the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.3
accessSwitchSysTempMinValue
The minimum temperature ever detected in Celsius by the sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.4
accessSwitchSysTempHighThresh
The high threshold of the temperature in Celsius. If the current temperature
is higher than the threshold, the device will initiate the overheat trap.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.6.1.5
accessSwitchSysTempDescr
The description of the temperature sensor (e.g. location, function, etc.).
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.6.1.6
.1.3.6.1.4.1.890.1.5.1.1.20 · 1 row entry · 1 columns
This table includes the configuration of packet forwarding.
asPacketForwardingEntry entry .1.3.6.1.4.1.890.1.5.1.1.20.1
An entry in asPacketForwardingTable.
Indexes
Column Syntax OID
asPacketForwardingPortList
The list defines the ports to which the packets
will be forwarded.
Q-BRIDGE-MIBPortListr/w
Textual Convention: Q-BRIDGE-MIBPortList OctetString
.1.3.6.1.4.1.890.1.5.1.1.20.1.1
.1.3.6.1.4.1.890.1.5.1.1.25 · 1 row entry · 2 columns
A table that contains DHCP server information.
asDhcpServerEntry entry .1.3.6.1.4.1.890.1.5.1.1.25.1
The entry of DHCP server table.
Indexes
asDhcpServerIp
Column Syntax OID
asDhcpServerIp
The IP address of the DHCP server.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.890.1.5.1.1.25.1.1
asDhcpServerRowStatus
The row status of the DHCP server entry.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.890.1.5.1.1.25.1.2
.1.3.6.1.4.1.890.1.5.1.1.29 · 1 row entry · 5 columns
A table that contains Radius Server information.
asRadiusServerEntry entry .1.3.6.1.4.1.890.1.5.1.1.29.1
The entry of Radius Server table.
Indexes
asRadiusServerIndex
Column Syntax OID
asRadiusServerIndex
The identity of the RADIUS server.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.29.1.1
asRadiusServerIp
The IP address of the Radius Server.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.890.1.5.1.1.29.1.2
asRadiusServerPort
The UDP port of the Radius Server.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.29.1.3
asRadiusSharedSecret
The shared secret of the Radius Server.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.890.1.5.1.1.29.1.4
asRadiusServerRowStatus
The row status of the Radius Server entry.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.890.1.5.1.1.29.1.5
.1.3.6.1.4.1.890.1.5.1.1.31 · 1 row entry · 4 columns
This table includes the configuration of 802.1x.
asDot1xPortEntry entry .1.3.6.1.4.1.890.1.5.1.1.31.1
An entry in asDot1xPortTable.
Indexes
Column Syntax OID
asDot1xPortEnable
The option defines if the port enables 802.1x
settings.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.890.1.5.1.1.31.1.1
asDot1xPortControl
The configuration defines the 802.1x port control
type.
Enumerationr/w
Enumerated Values:
1auto
2forceAuth
3forceUnAuth
.1.3.6.1.4.1.890.1.5.1.1.31.1.2
asDot1xPortReAuthEnable
The option defines if the port enables 802.1x
re-authentication.
Enumerationr/w
Enumerated Values:
1on
2off
.1.3.6.1.4.1.890.1.5.1.1.31.1.3
asDot1xPortReAuthPeriod
The configuration defines the 802.1x
re-authentication period for each port.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.1.31.1.4
.1.3.6.1.4.1.890.1.5.1.2.1.2 · 1 row entry · 3 columns
A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame.
asMacEntry entry .1.3.6.1.4.1.890.1.5.1.2.1.2.1
An entry of asMacTable.
Indexes
asMacAddress
Column Syntax OID
asMacAddress
A unicast MAC address for which the bridge has
forwarding and/or filtering information.
SNMPv2-TCMacAddress
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.890.1.5.1.2.1.2.1.1
asMacPort
The port from which the mac address has been learned.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.890.1.5.1.2.1.2.1.2
asMacStatus
The status of this entry.
Enumeration
Enumerated Values:
1other
2invalid
3learned
4self
5mgmt
.1.3.6.1.4.1.890.1.5.1.2.1.2.1.3