ZHNSYSMON
This MIB contains objects that are used by the System
Monitoring function.
==============================================================
== ==
== Copyright (C) 2007-2010 Zhone Technologies, Inc. ==
== ==
==============================================================
zhnSysMon
1.3.6.1.4.1.5504.2.5.1
Imported Objects
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime DisplayString RowStatus |
| Zhone | zhoneWtn |
Objects (29)
|
|
.1.3.6.1.4.1.5504.2.5.1 |
|
|
|
.1.3.6.1.4.1.5504.2.5.1.0 |
|
|
|
.1.3.6.1.4.1.5504.2.5.1.1 |
|
|
|
.1.3.6.1.4.1.5504.2.5.1.1.1 |
|
|
|
zhnSysMonAlarmTypezhnSysMonAlarmSeverityzhnSysMonAlarmInterfaceName | .1.3.6.1.4.1.5504.2.5.1.1.1.1 |
|
|
Enumeration | .1.3.6.1.4.1.5504.2.5.1.1.1.1.1 |
|
|
Enumeration | .1.3.6.1.4.1.5504.2.5.1.1.1.1.2 |
|
|
OctetString | .1.3.6.1.4.1.5504.2.5.1.1.1.1.3 |
|
|
OctetString | .1.3.6.1.4.1.5504.2.5.1.1.1.1.4 |
|
|
SNMPv2-TCRowStatus | .1.3.6.1.4.1.5504.2.5.1.1.1.1.5 |
|
|
.1.3.6.1.4.1.5504.2.5.1.1.2 |
|
|
|
zhnSysMonTestTypezhnSysMonTestInterfaceName | .1.3.6.1.4.1.5504.2.5.1.1.2.1 |
|
|
Enumeration | .1.3.6.1.4.1.5504.2.5.1.1.2.1.1 |
|
|
OctetString | .1.3.6.1.4.1.5504.2.5.1.1.2.1.2 |
|
|
SNMPv2-TCRowStatus | .1.3.6.1.4.1.5504.2.5.1.1.2.1.3 |
|
|
.1.3.6.1.4.1.5504.2.5.1.1.3 |
|
|
|
zhnSysMonTempSensorId | .1.3.6.1.4.1.5504.2.5.1.1.3.1 |
|
|
Unsigned32 | .1.3.6.1.4.1.5504.2.5.1.1.3.1.1 |
|
|
SNMPv2-TCRowStatus | .1.3.6.1.4.1.5504.2.5.1.1.3.1.2 |
|
|
OctetString | .1.3.6.1.4.1.5504.2.5.1.1.3.1.3 |
|
|
OctetString | .1.3.6.1.4.1.5504.2.5.1.1.3.1.4 |
|
|
OctetString | .1.3.6.1.4.1.5504.2.5.1.1.3.1.5 |
|
|
OctetString | .1.3.6.1.4.1.5504.2.5.1.1.3.1.6 |
|
|
.1.3.6.1.4.1.5504.2.5.1.1.4 |
|
|
|
zhnSysMonLinePowerLineNumber | .1.3.6.1.4.1.5504.2.5.1.1.4.1 |
|
|
Unsigned32 | .1.3.6.1.4.1.5504.2.5.1.1.4.1.1 |
|
|
Enumeration | .1.3.6.1.4.1.5504.2.5.1.1.4.1.2 |
|
|
SNMPv2-TCRowStatus | .1.3.6.1.4.1.5504.2.5.1.1.4.1.3 |
|
|
.1.3.6.1.4.1.5504.2.5.1.2 |
Notifications / Traps (8)
| Name | OID | Description |
|---|---|---|
|
|
.1.3.6.1.4.1.5504.2.5.1.0.1 |
A zhnSysMonAlarmSetEvent notification is sent when an
alarm condition is detected by a system component.
The System Monitor is informed of the alarm and
generates the alarm set notification.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonAlarmTable.
|
|
|
.1.3.6.1.4.1.5504.2.5.1.0.2 |
A zhnSysMonAlarmClearEvent notification is sent when an
alarm condition is cleared by a system component.
The System Monitor is informed of the alarm state and
generates the alarm clear notification.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonAlarmTable.
|
|
|
.1.3.6.1.4.1.5504.2.5.1.0.3 |
A zhnSysMonTestStartEvent notification is sent by
any system component that begins a test.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonTestTable.
|
|
|
.1.3.6.1.4.1.5504.2.5.1.0.4 |
A zhnSysMonTestStopEvent notification is sent by
any system component that ends a test.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonTestTable.
|
|
|
.1.3.6.1.4.1.5504.2.5.1.0.5 |
A zhnSysMonTempCfgUpdateEvent notification is sent by
the System Monitor whenever it reconfigures a
temperature sensor.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonTempSensorTable.
|
|
|
.1.3.6.1.4.1.5504.2.5.1.0.6 |
A zhnSysMonLinePowerCfgUpdateEvent notification is sent by
the System Monitor whenever it reconfigures a power source
line.
The objects in the notification correspond to the values
in a row instance of in the zhnSysMonLinePowerTable.
|
|
|
.1.3.6.1.4.1.5504.2.5.1.0.7 |
A zhnSysMonReadyEvent notification is sent by the System Monitor whenever it has completed initialization and is ready to accept requests. |
|
|
.1.3.6.1.4.1.5504.2.5.1.0.8 |
A zhnSysMonConfigChangeEvent notification is generated whenever the persistent database is saved. |