WebGraph-Thermometer-US-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
7
Rows
7
Columns
42
.1.3.6.1.4.1.5040.1.2.8.1.2 · 1 row entry · 1 columns
List of sensors.
wtWebioAn1GraphSensorEntry entry .1.3.6.1.4.1.5040.1.2.8.1.2.1
Temperature sensor numbers.
Indexes
wtWebioAn1GraphSensorNo
Column Syntax OID
wtWebioAn1GraphSensorNo mandatory
Temperature sensor number.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.8.1.2.1.1
.1.3.6.1.4.1.5040.1.2.8.1.3 · 1 row entry · 1 columns
List of temperature values corresponding to the channel numbers.
wtWebioAn1GraphTempValueEntry entry .1.3.6.1.4.1.5040.1.2.8.1.3.1
Temperatures of the sensors.
Indexes
wtWebioAn1GraphSensorNo
Column Syntax OID
wtWebioAn1GraphTempValue mandatory
Temperature value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.8.1.3.1.1
.1.3.6.1.4.1.5040.1.2.8.1.4 · 1 row entry · 1 columns
List of binary temperature values corresponding to the channel numbers.
wtWebioAn1GraphBinaryTempValueEntry entry .1.3.6.1.4.1.5040.1.2.8.1.4.1
Binary temperature values of the sensors.
Indexes
wtWebioAn1GraphSensorNo
Column Syntax OID
wtWebioAn1GraphBinaryTempValue mandatory
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.8.1.4.1.1
.1.3.6.1.4.1.5040.1.2.8.3.1.4.4 · 1 row entry · 1 columns
List of sensor colors for the praphical presentation.
wtWebioAn1GraphSensorColorEntry entry .1.3.6.1.4.1.5040.1.2.8.3.1.4.4.1
Index numbers of the sensors.
Indexes
wtWebioAn1GraphSensorNo
Column Syntax OID
wtWebioAn1GraphSensorColor mandatory
Color of the sensors at the praphical presention.
OctetStringr/w
Constraints:
range: 3-3
.1.3.6.1.4.1.5040.1.2.8.3.1.4.4.1.1
.1.3.6.1.4.1.5040.1.2.8.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioAn1GraphAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.8.3.1.5.2.1
Numbers of the alarms.
Indexes
wtWebioAn1GraphAlarmNo
Column Syntax OID
wtWebioAn1GraphAlarmNo mandatory
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.8.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3 · 1 row entry · 30 columns
List of settings depending on the alarm number.
wtWebioAn1GraphAlarmEntry entry .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
wtWebioAn1GraphAlarmNo
Column Syntax OID
wtWebioAn1GraphAlarmTrigger mandatory
Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart

Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
B…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.1
wtWebioAn1GraphAlarmMin mandatory
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.2
wtWebioAn1GraphAlarmMax mandatory
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.3
wtWebioAn1GraphAlarmHysteresis mandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.4
wtWebioAn1GraphAlarmDelay mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes).
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.5
wtWebioAn1GraphAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.6
wtWebioAn1GraphAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.7
wtWebioAn1GraphAlarmEMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.8
wtWebioAn1GraphAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.9
wtWebioAn1GraphAlarmMailText mandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.10
wtWebioAn1GraphAlarmManagerIP mandatory
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.11
wtWebioAn1GraphAlarmTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.12
wtWebioAn1GraphAlarmMailOptions mandatory
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.13
wtWebioAn1GraphAlarmTcpIpAddr mandatory
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.14
wtWebioAn1GraphAlarmTcpPort mandatory
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.15
wtWebioAn1GraphAlarmTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.16
wtWebioAn1GraphAlarmClearMailSubject mandatory
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.17
wtWebioAn1GraphAlarmClearMailText mandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.18
wtWebioAn1GraphAlarmClearTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.19
wtWebioAn1GraphAlarmClearTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.20
wtWebioAn1GraphAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.21
wtWebioAn1GraphAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.22
wtWebioAn1GraphAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.23
wtWebioAn1GraphAlarmSyslogClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.24
wtWebioAn1GraphAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.25
wtWebioAn1GraphAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.26
wtWebioAn1GraphAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.27
wtWebioAn1GraphAlarmFtpClearText mandatory
Alarm clear message to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.28
wtWebioAn1GraphAlarmFtpOptions mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.29
wtWebioAn1GraphAlarmTimerCron mandatory
This entry contains 5 text fields space or tab seperated for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separately.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.1.5.3.1.30
.1.3.6.1.4.1.5040.1.2.8.3.2.1 · 1 row entry · 7 columns
List of settings depending on the sensor number.
wtWebioAn1GraphPortEntry entry .1.3.6.1.4.1.5040.1.2.8.3.2.1.1
Sensor parameters for the individual sensors.
Indexes
wtWebioAn1GraphSensorNo
Column Syntax OID
wtWebioAn1GraphPortName mandatory
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.2.1.1.1
wtWebioAn1GraphPortText mandatory
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2
wtWebioAn1GraphPortOffset1 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.2.1.1.3
wtWebioAn1GraphPortTemperature1 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.2.1.1.4
wtWebioAn1GraphPortOffset2 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.2.1.1.5
wtWebioAn1GraphPortTemperature2 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.2.1.1.6
wtWebioAn1GraphPortComment mandatory
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.8.3.2.1.1.7