WebGraph-OLD-Thermo-Hygro-Barometer-US-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
7
Rows
7
Columns
48
.1.3.6.1.4.1.5040.1.2.16.1.2 · 1 row entry · 1 columns
List of sensors.
wtWebGraphThermoBaroSensorEntry entry .1.3.6.1.4.1.5040.1.2.16.1.2.1
List of sensor numbers.
Indexes
wtWebGraphThermoBaroSensorNo
Column Syntax OID
wtWebGraphThermoBaroSensorNo mandatory
Sensor number.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.16.1.2.1.1
.1.3.6.1.4.1.5040.1.2.16.1.3 · 1 row entry · 1 columns
List of measurement values corresponding to the channel numbers.
wtWebGraphThermoBaroTempValueEntry entry .1.3.6.1.4.1.5040.1.2.16.1.3.1
Measurement values of the sensors.
Indexes
wtWebGraphThermoBaroSensorNo
Column Syntax OID
wtWebGraphThermoBaroTempValue mandatory
Measurement value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.16.1.3.1.1
.1.3.6.1.4.1.5040.1.2.16.1.4 · 1 row entry · 1 columns
List of binary measurement values corresponding to the channel numbers.
wtWebGraphThermoBaroBinaryTempValueEntry entry .1.3.6.1.4.1.5040.1.2.16.1.4.1
Binary measurement values of the sensors.
Indexes
wtWebGraphThermoBaroSensorNo
Column Syntax OID
wtWebGraphThermoBaroBinaryTempValue mandatory
Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent,
signed number, 0x4FFF6 indicates an
invalid measured value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.16.1.4.1.1
.1.3.6.1.4.1.5040.1.2.16.1.8 · 1 row entry · 1 columns
List of measurement values corresponding to the channel numbers.
wtWebGraphThermoBaroTempValuePktEntry entry .1.3.6.1.4.1.5040.1.2.16.1.8.1
Measurement values of the sensors.
Indexes
wtWebGraphThermoBaroSensorNo
Column Syntax OID
wtWebGraphThermoBaroTempValuePkt mandatory
Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.16.1.8.1.1
.1.3.6.1.4.1.5040.1.2.16.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebGraphThermoBaroAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.16.3.1.5.2.1
Numbers of the alarms.
Indexes
wtWebGraphThermoBaroAlarmNo
Column Syntax OID
wtWebGraphThermoBaroAlarmNo mandatory
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.16.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3 · 1 row entry · 36 columns
List of settings depending on the alarm number.
wtWebGraphThermoBaroAlarmEntry entry .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
wtWebGraphThermoBaroAlarmNo
Column Syntax OID
wtWebGraphThermoBaroAlarmTrigger mandatory
Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart

Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.1
wtWebGraphThermoBaroAlarmMin mandatory
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.2
wtWebGraphThermoBaroAlarmMax mandatory
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.3
wtWebGraphThermoBaroAlarmHysteresis mandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.4
wtWebGraphThermoBaroAlarmDelay mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes).
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.5
wtWebGraphThermoBaroAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.6
wtWebGraphThermoBaroAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.7
wtWebGraphThermoBaroAlarmEMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.8
wtWebGraphThermoBaroAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.9
wtWebGraphThermoBaroAlarmMailText mandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.10
wtWebGraphThermoBaroAlarmManagerIP mandatory
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.11
wtWebGraphThermoBaroAlarmTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.12
wtWebGraphThermoBaroAlarmMailOptions mandatory
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.13
wtWebGraphThermoBaroAlarmTcpIpAddr mandatory
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.14
wtWebGraphThermoBaroAlarmTcpPort mandatory
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.15
wtWebGraphThermoBaroAlarmTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.16
wtWebGraphThermoBaroAlarmClearMailSubject mandatory
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.17
wtWebGraphThermoBaroAlarmClearMailText mandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.18
wtWebGraphThermoBaroAlarmClearTrapText mandatory
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.19
wtWebGraphThermoBaroAlarmClearTcpText mandatory
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.20
wtWebGraphThermoBaroAlarmDeltaTemp mandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.21
wtWebGraphThermoBaroAlarmRHMin mandatory
Minimum rel. Humidity in percent with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.22
wtWebGraphThermoBaroAlarmRHMax mandatory
Maximum rel.Humidity in percent with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.23
wtWebGraphThermoBaroAlarmRHHysteresis mandatory
Hysterese rel. Humidity in percent with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.24
wtWebGraphThermoBaroAlarmAHMin mandatory
Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.25
wtWebGraphThermoBaroAlarmAHMax mandatory
Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.26
wtWebGraphThermoBaroAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.27
wtWebGraphThermoBaroAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.28
wtWebGraphThermoBaroAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.29
wtWebGraphThermoBaroAlarmSyslogClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.30
wtWebGraphThermoBaroAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.31
wtWebGraphThermoBaroAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.32
wtWebGraphThermoBaroAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.33
wtWebGraphThermoBaroAlarmFtpClearText mandatory
Alarm clear message to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.34
wtWebGraphThermoBaroAlarmFtpOptions mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.35
wtWebGraphThermoBaroAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.1.5.3.1.36
.1.3.6.1.4.1.5040.1.2.16.3.2.1 · 1 row entry · 7 columns
List of settings depending on the sensor number.
wtWebGraphThermoBaroPortEntry entry .1.3.6.1.4.1.5040.1.2.16.3.2.1.1
Sensor parameters for the individual sensors.
Indexes
wtWebGraphThermoBaroSensorNo
Column Syntax OID
wtWebGraphThermoBaroPortName mandatory
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.2.1.1.1
wtWebGraphThermoBaroPortText mandatory
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.2.1.1.2
wtWebGraphThermoBaroPortOffset1 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.2.1.1.3
wtWebGraphThermoBaroPortTemperature1 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.2.1.1.4
wtWebGraphThermoBaroPortOffset2 mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.2.1.1.5
wtWebGraphThermoBaroPortTemperature2 mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.2.1.1.6
wtWebGraphThermoBaroPortComment mandatory
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.16.3.2.1.1.7