WebGraph-AnalogIn-57644-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
8
Rows
8
Columns
51
.1.3.6.1.4.1.5040.1.2.12.1.2
·
1 row entry
·
1 columns
List of sensors.
List of sensor numbers.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644SensorNo
mandatory
Sensor number.
|
Integer32 | .1.3.6.1.4.1.5040.1.2.12.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.12.1.3
·
1 row entry
·
1 columns
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644Values
mandatory
Measurement value of the sensor, ASCII, 7 characters in length.
|
OctetString | .1.3.6.1.4.1.5040.1.2.12.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.12.1.4
·
1 row entry
·
1 columns
List of binary measurement values corresponding to the channel numbers.
Binary measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644BinaryValues
mandatory
Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent,
signed number, 0x4FFF6 indicates an invalid measured value. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.12.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.12.3.1.4.4
·
1 row entry
·
1 columns
List of sensor colors for the praphical presentation.
Index numbers of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644SensorColor
mandatory
Color of the sensors at the praphical presention.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.4.4.1.1 |
.1.3.6.1.4.1.5040.1.2.12.3.1.5.2
·
1 row entry
·
1 columns
List of alarm indices.
Numbers of the alarms.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644AlarmNo
mandatory
Alarm number.
|
Integer32 | .1.3.6.1.4.1.5040.1.2.12.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.12.3.1.5.3
·
1 row entry
·
33 columns
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644AlarmTrigger
mandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.1 |
|
wtWebGraphAnalogIn57644AlarmMin
mandatory
Minimum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.2 |
|
wtWebGraphAnalogIn57644AlarmMax
mandatory
Maximum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.3 |
|
wtWebGraphAnalogIn57644AlarmHysteresis
mandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.4 |
|
wtWebGraphAnalogIn57644AlarmDelay
mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.5 |
|
wtWebGraphAnalogIn57644AlarmInterval
mandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.6 |
|
wtWebGraphAnalogIn57644AlarmEnable
mandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.7 |
|
wtWebGraphAnalogIn57644AlarmEMailAddr
mandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.8 |
|
wtWebGraphAnalogIn57644AlarmMailSubject
mandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.9 |
|
wtWebGraphAnalogIn57644AlarmMailText
mandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.10 |
|
wtWebGraphAnalogIn57644AlarmManagerIP
mandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.11 |
|
wtWebGraphAnalogIn57644AlarmTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.12 |
|
wtWebGraphAnalogIn57644AlarmMailOptions
mandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.13 |
|
wtWebGraphAnalogIn57644AlarmTcpIpAddr
mandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.14 |
|
wtWebGraphAnalogIn57644AlarmTcpPort
mandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.15 |
|
wtWebGraphAnalogIn57644AlarmTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.16 |
|
wtWebGraphAnalogIn57644AlarmClearMailSubject
mandatory
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.17 |
|
wtWebGraphAnalogIn57644AlarmClearMailText
mandatory
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.18 |
|
wtWebGraphAnalogIn57644AlarmClearTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.19 |
|
wtWebGraphAnalogIn57644AlarmClearTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.20 |
|
wtWebGraphAnalogIn57644Alarm2Min
mandatory
Minimum rel. Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.21 |
|
wtWebGraphAnalogIn57644Alarm2Max
mandatory
Maximum rel.Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.22 |
|
wtWebGraphAnalogIn57644Alarm2Hysteresis
mandatory
Hysterese rel. Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.23 |
|
wtWebGraphAnalogIn57644AlarmSyslogIpAddr
mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.24 |
|
wtWebGraphAnalogIn57644AlarmSyslogPort
mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.25 |
|
wtWebGraphAnalogIn57644AlarmSyslogText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.26 |
|
wtWebGraphAnalogIn57644AlarmSyslogClearText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.27 |
|
wtWebGraphAnalogIn57644AlarmFtpDataPort
mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.28 |
|
wtWebGraphAnalogIn57644AlarmFtpFileName
mandatory
Name of the file including path informations.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.29 |
|
wtWebGraphAnalogIn57644AlarmFtpText
mandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.30 |
|
wtWebGraphAnalogIn57644AlarmFtpClearText
mandatory
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.31 |
|
wtWebGraphAnalogIn57644AlarmFtpOption
mandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.32 |
|
wtWebGraphAnalogIn57644AlarmTimerCron
mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Rang… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.5.3.1.33 |
.1.3.6.1.4.1.5040.1.2.12.3.1.6.2.3
·
1 row entry
·
2 columns
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644GraphicsSensorColor
mandatory
Color of the sensors at the praphical presention.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.6.2.3.1.1 |
|
wtWebGraphAnalogIn57644GraphicsSelectScale
mandatory
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 … |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.12.3.2.1
·
1 row entry
·
11 columns
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalogIn57644PortName
mandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.1 |
|
wtWebGraphAnalogIn57644PortText
mandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.2 |
|
wtWebGraphAnalogIn57644PortOffset1
mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at set point 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.3 |
|
wtWebGraphAnalogIn57644SetPoint1
mandatory
Offset calibration: set point 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.4 |
|
wtWebGraphAnalogIn57644PortOffset2
mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at set point 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.5 |
|
wtWebGraphAnalogIn57644SetPoint2
mandatory
Offset calibration: set point 2 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.6 |
|
wtWebGraphAnalogIn57644PortComment
mandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.7 |
|
wtWebGraphAnalogIn57644PortSensorSelect
mandatory
Binary coded options for sensor 1:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-10V (default) Bit 1 : Disconnect Bit 2-7: unused Binary coded options for sensor 2: Octet 1: u… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.8 |
|
wtWebGraphAnalogIn57644PortUnit
mandatory
User scale: displayed unit.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.9 |
|
wtWebGraphAnalogIn57644PortScale0
mandatory
User scale: displayed value in 1/1000 at 0% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.10 |
|
wtWebGraphAnalogIn57644PortScale100
mandatory
User scale: displayed value in 1/1000 at 100% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.12.3.2.1.1.11 |