WebGraph-AnalogIO-57761-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
10
Rows
10
Columns
100
.1.3.6.1.4.1.5040.1.2.28.1.2
·
1 row entry
·
1 columns
List of sensors.
List of sensor numbers.
Indexes
wtWebGraphAnalog57761SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761SensorNo
mandatory
Sensor number.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.5040.1.2.28.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.28.1.3
·
1 row entry
·
1 columns
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
wtWebGraphAnalog57761SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761Values
mandatory
Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings for the read and write operations. |
OctetStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.28.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.28.1.4
·
1 row entry
·
1 columns
List of binary measurement values corresponding to the channel numbers.
Binary measurement values of the sensors.
Indexes
wtWebGraphAnalog57761SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761BinaryValues
mandatory
Binary measurement value of the sensor in 1/1000,
signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports settings for the read and write operations. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.28.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.28.1.8
·
1 row entry
·
1 columns
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
wtWebGraphAnalog57761SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761ValuesPoint
mandatory
Measurement value of the sensor, ASCII.
This value will be translated according to the ports settings for the read and write operations. |
OctetStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.5040.1.2.28.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.2
·
1 row entry
·
1 columns
Table of indices.
Indices of the binary channels.
Indexes
wtWebGraphAnalog57761BinaryModeNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761BinaryModeNo
mandatory
Number of the binary channel.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.2.1.1 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3
·
1 row entry
·
29 columns
Table of properties of the binary mode.
Binary properties.
Indexes
wtWebGraphAnalog57761BinaryModeNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761BinaryOperationMode
mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.1 |
|
wtWebGraphAnalog57761BinaryTcpServerLocalPort
mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.2 |
|
wtWebGraphAnalog57761BinaryTcpServerInputTrigger
mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.3 |
|
wtWebGraphAnalog57761BinaryTcpServerApplicationMode
mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box S… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.4 |
|
wtWebGraphAnalog57761BinaryTcpClientLocalPort
mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.5 |
|
wtWebGraphAnalog57761BinaryTcpClientServerPort
mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.6 |
|
wtWebGraphAnalog57761BinaryTcpClientServerIpAddr
mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.7 |
|
wtWebGraphAnalog57761BinaryTcpClientServerPassword
mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.8 |
|
wtWebGraphAnalog57761BinaryTcpClientInactivity
mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.9 |
|
wtWebGraphAnalog57761BinaryTcpClientInputTrigger
mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.10 |
|
wtWebGraphAnalog57761BinaryTcpClientInterval
mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the periodical sending. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.11 |
|
wtWebGraphAnalog57761BinaryTcpClientApplicationMode
mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compat… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.12 |
|
wtWebGraphAnalog57761BinaryUdpPeerLocalPort
mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device. Reserved port number must not be used (refere to the manual). |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.13 |
|
wtWebGraphAnalog57761BinaryUdpPeerRemotePort
mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.14 |
|
wtWebGraphAnalog57761BinaryUdpPeerRemoteIpAddr
mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.15 |
|
wtWebGraphAnalog57761BinaryUdpPeerInputTrigger
mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.16 |
|
wtWebGraphAnalog57761BinaryUdpPeerInterval
mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the periodical sending. |
Integer32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.17 |
|
wtWebGraphAnalog57761BinaryUdpPeerApplicationMode
mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.18 |
|
wtWebGraphAnalog57761BinaryConnectedPort
mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read. |
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.19 |
|
wtWebGraphAnalog57761BinaryConnectedIpAddr
mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read. |
RFC1155-SMIIpAddress Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.20 |
|
wtWebGraphAnalog57761BinaryTcpServerClientHttpPort
mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port. Not used at mode Compatible 50xxx. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.21 |
|
wtWebGraphAnalog57761BinaryTcpClientServerHttpPort
mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port. |
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.22 |
|
wtWebGraphAnalog57761BinaryTcpServerHysteresis1
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57761BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.23 |
|
wtWebGraphAnalog57761BinaryTcpServerHysteresis2
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57761BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.24 |
|
wtWebGraphAnalog57761BinaryTcpClientHysteresis1
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57761BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.25 |
|
wtWebGraphAnalog57761BinaryTcpClientHysteresis2
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57761BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.26 |
|
wtWebGraphAnalog57761BinaryUdpPeerHysteresis1
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 1 must be selected at wtWebGraphAnalog57761BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.27 |
|
wtWebGraphAnalog57761BinaryUdpPeerHysteresis2
mandatory
A change greater than this value initiate a transmission of the corresponding input value.
The input 2 must be selected at wtWebGraphAnalog57761BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.28 |
|
wtWebGraphAnalog57761BinaryTcpClientServerUserName
mandatory
Building a connection may be protected by a specific
user name within the server. Enter the user name to establish the connection, if a user name entry exists. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.3.9.3.1.29 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.2
·
1 row entry
·
1 columns
List of alarm indices.
Numbers of the alarms.
Indexes
wtWebGraphAnalog57761AlarmNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761AlarmNo
mandatory
Alarm number.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3
·
1 row entry
·
49 columns
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
wtWebGraphAnalog57761AlarmNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761AlarmTrigger
mandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.1 |
|
wtWebGraphAnalog57761AlarmMin1
mandatory
Minimum sensor 1 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.2 |
|
wtWebGraphAnalog57761AlarmMax1
mandatory
Maximum sensor 1 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.3 |
|
wtWebGraphAnalog57761AlarmHysteresis1
mandatory
Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
with maximum 3 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.4 |
|
wtWebGraphAnalog57761AlarmDelay
mandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.5 |
|
wtWebGraphAnalog57761AlarmInterval
mandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.6 |
|
wtWebGraphAnalog57761AlarmEnable
mandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog enable Bit 4: FTP Client enable |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.7 |
|
wtWebGraphAnalog57761AlarmEMailAddr
mandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.8 |
|
wtWebGraphAnalog57761AlarmMailSubject
mandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.9 |
|
wtWebGraphAnalog57761AlarmMailText
mandatory
Alarm mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.10 |
|
wtWebGraphAnalog57761AlarmManagerIP
mandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.11 |
|
wtWebGraphAnalog57761AlarmTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.12 |
|
wtWebGraphAnalog57761AlarmMailOptions
mandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Logger.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.13 |
|
wtWebGraphAnalog57761AlarmTcpIpAddr
mandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.14 |
|
wtWebGraphAnalog57761AlarmTcpPort
mandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.15 |
|
wtWebGraphAnalog57761AlarmTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.16 |
|
wtWebGraphAnalog57761AlarmClearMailSubject
mandatory
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.17 |
|
wtWebGraphAnalog57761AlarmClearMailText
mandatory
Alarm clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.18 |
|
wtWebGraphAnalog57761AlarmClearTrapText
mandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.19 |
|
wtWebGraphAnalog57761AlarmClearTcpText
mandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.20 |
|
wtWebGraphAnalog57761AlarmMin2
mandatory
Minimum sensor 2 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.21 |
|
wtWebGraphAnalog57761AlarmMax2
mandatory
Maximum sensor 2 with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.22 |
|
wtWebGraphAnalog57761AlarmHysteresis2
mandatory
Hysterese rel. sensor 2 with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.23 |
|
wtWebGraphAnalog57761AlarmSyslogIpAddr
mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.24 |
|
wtWebGraphAnalog57761AlarmSyslogPort
mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.25 |
|
wtWebGraphAnalog57761AlarmSyslogText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.26 |
|
wtWebGraphAnalog57761AlarmSyslogClearText
mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.27 |
|
wtWebGraphAnalog57761AlarmFtpDataPort
mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.28 |
|
wtWebGraphAnalog57761AlarmFtpFileName
mandatory
Name of the file including path informations.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.29 |
|
wtWebGraphAnalog57761AlarmFtpText
mandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.30 |
|
wtWebGraphAnalog57761AlarmFtpClearText
mandatory
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.31 |
|
wtWebGraphAnalog57761AlarmFtpOption
mandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.32 |
|
wtWebGraphAnalog57761AlarmTimerCron
mandatory
This entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.33 |
|
wtWebGraphAnalog57761AlarmName
mandatory
Alert name
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.39 |
|
wtWebGraphAnalog57761AlarmActive
mandatory
Alert active
1 = ON 0 = OFF |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.40 |
|
wtWebGraphAnalog57761AlarmHttpReqAuthEnable
mandatory
Binary coded options, select only one option at the same time:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.61 |
|
wtWebGraphAnalog57761AlarmHttpReqAuthUser
mandatory
HTTP Request: User
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.62 |
|
wtWebGraphAnalog57761AlarmHttpReqAuthPassword
mandatory
HTTP Request: Password
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.63 |
|
wtWebGraphAnalog57761AlarmHttpReqSetUrl
mandatory
HTTP Request: Set URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.64 |
|
wtWebGraphAnalog57761AlarmHttpReqClearUrl
mandatory
HTTP Request: Clear URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.65 |
|
wtWebGraphAnalog57761AlarmHttpReqServerPort
mandatory
HTTP Request: Server Port
|
Integer32r/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.66 |
|
wtWebGraphAnalog57761AlarmMqttTopicPath
mandatory
MQTT Publish: Topic path
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.67 |
|
wtWebGraphAnalog57761AlarmMqttTopicSetTopic
mandatory
MQTT Publish: Topic SET message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.68 |
|
wtWebGraphAnalog57761AlarmMqttTopicClear
mandatory
MQTT Publish: Topic CLEAR message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.69 |
|
wtWebGraphAnalog57761AlarmSensorLostSelection
mandatory
Binary coded options:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.70 |
|
wtWebGraphAnalog57761AlarmLimitWindow
mandatory
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.71 |
|
wtWebGraphAnalog57761AlarmSnmpManagerPort
mandatory
Port number of the SNMP Manager to which the Webio device should send SNMP traps.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.76 |
|
wtWebGraphAnalog57761AlarmMqttQoS
mandatory
Binary coded value:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.77 |
|
wtWebGraphAnalog57761AlarmMqttRetain
mandatory
Binary coded value:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.1.5.3.1.78 |
.1.3.6.1.4.1.5040.1.2.28.3.1.6.2.3
·
1 row entry
·
2 columns
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
wtWebGraphAnalog57761SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761GraphicsSensorColor
mandatory
Color of the sensors at the praphical presention.
|
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.28.3.1.6.2.3.1.1 |
|
wtWebGraphAnalog57761GraphicsSelectScale
mandatory
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.28.3.2.1
·
1 row entry
·
14 columns
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
wtWebGraphAnalog57761SensorNo
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAnalog57761PortName
mandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.1 |
|
wtWebGraphAnalog57761PortText
mandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.2 |
|
wtWebGraphAnalog57761PortOffset1
mandatory
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.3 |
|
wtWebGraphAnalog57761SetPoint1
mandatory
Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.4 |
|
wtWebGraphAnalog57761PortOffset2
mandatory
Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.5 |
|
wtWebGraphAnalog57761SetPoint2
mandatory
Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.6 |
|
wtWebGraphAnalog57761PortComment
mandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.7 |
|
wtWebGraphAnalog57761PortSensorSelect
mandatory
Binary coded options for sensor 1:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.2.1.1.8 |
|
wtWebGraphAnalog57761PortUnit
mandatory
User scale: displayed unit.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.9 |
|
wtWebGraphAnalog57761PortScale0
mandatory
User scale: displayed value in 1/1000 at 0% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.10 |
|
wtWebGraphAnalog57761PortScale100
mandatory
User scale: displayed value in 1/1000 at 100% full scale range.
Range: -999999.999 to 999999.999 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.11 |
|
wtWebGraphAnalog57761PortOutputMode
mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected. If an output mode is selected, Bit 2 in wtWebGraphAnalog57761PortInputMode will be set automat… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.2.1.1.12 |
|
wtWebGraphAnalog57761PortInputMode
mandatory
This binary coded input mode defines the individual operation mode for any
input. More than one mode must not be selected. If an input mode is selected, Bit 5 in wtWebGraphAnalog57761PortOutputMode will be set automatic… |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.28.3.2.1.1.13 |
|
wtWebGraphAnalog57761PortPresetValue
mandatory
This value will be set after reset or initialisation.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.28.3.2.1.1.16 |