TEMPAGER-MIB
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress TimeTicks |
Objects (28)
|
|
.1.3.6.1.4.1.20916 |
|
|
|
.1.3.6.1.4.1.20916.1 |
|
|
|
.1.3.6.1.4.1.20916.1.1 |
|
|
|
.1.3.6.1.4.1.20916.1.1.1 |
|
|
|
.1.3.6.1.4.1.20916.1.1.1.1 |
|
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.1 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.2 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.3 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.4 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.5 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.6 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.7 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.1.1.8 |
|
|
.1.3.6.1.4.1.20916.1.1.2 |
|
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.2.1 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.2.2 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.2.3 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.2.4 |
|
|
OctetString | .1.3.6.1.4.1.20916.1.1.2.5 |
|
|
.1.3.6.1.4.1.20916.1.1.3 |
|
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.1 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.2 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.3 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.4 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.5 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.6 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.7 |
|
|
Integer32 | .1.3.6.1.4.1.20916.1.1.3.8 |
Notifications / Traps (8)
| Name | OID | Description |
|---|---|---|
|
|
.1.3.6.1.4.1.20916.1.1.0.1 |
A alarmstart1 trap signifies that the current temperature on sensor 1 is outside the defined high or low threshold. |
|
|
.1.3.6.1.4.1.20916.1.1.0.2 |
A tempager-snmp-trap indicates that an alarm condition has occurred on the sensor inidcated by the alarmmessage variable. |
|
|
.1.3.6.1.4.1.20916.1.1.0.3 |
A alarmstart2 trap signifies that the current temperature on sensor 2 is outside the defined high or low threshold. |
|
|
.1.3.6.1.4.1.20916.1.1.0.4 |
A alarmclear2 trap signifies that the current temperature on sensor 2 has returned to a normal condition and is within the defined high or low threshold. |
|
|
.1.3.6.1.4.1.20916.1.1.0.5 |
A alarmstart3 trap signifies that the current temperature on sensor 3 is outside the defined high or low threshold. |
|
|
.1.3.6.1.4.1.20916.1.1.0.6 |
A alarmclear3 trap signifies that the current temperature on sensor 3 has returned to a normal condition and is within the defined high or low threshold. |
|
|
.1.3.6.1.4.1.20916.1.1.0.7 |
A alarmstart4 trap signifies that the current temperature on sensor 4 is outside the defined high or low threshold. |
|
|
.1.3.6.1.4.1.20916.1.1.0.8 |
A alarmclear4 trap signifies that the current temperature on sensor 4 has returned to a normal condition and is within the defined high or low threshold. |