TEMPAGER-MIB

Imported Objects
RFC-1212 OBJECT-TYPE
RFC-1215 TRAP-TYPE
RFC1155-SMI Counter enterprises IpAddress TimeTicks
Objects (28)
avtech .1.3.6.1.4.1.20916
products .1.3.6.1.4.1.20916.1
tempager .1.3.6.1.4.1.20916.1.1
sensors .1.3.6.1.4.1.20916.1.1.1
temperature .1.3.6.1.4.1.20916.1.1.1.1
tempreading1c mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.1
tempreading2c mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.2
tempreading3c mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.3
tempreading4c mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.4
tempreading1f mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.5
tempreading2f mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.6
tempreading3f mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.7
tempreading4f mandatory Integer32 .1.3.6.1.4.1.20916.1.1.1.1.8
traps .1.3.6.1.4.1.20916.1.1.2
alarmtemp1 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.2.1
alarmtemp2 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.2.2
alarmtemp3 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.2.3
alarmtemp4 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.2.4
alarmmessage mandatory r/w OctetString .1.3.6.1.4.1.20916.1.1.2.5
thresholds .1.3.6.1.4.1.20916.1.1.3
upperlimit1 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.1
lowerlimit1 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.2
upperlimit2 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.3
lowerlimit2 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.4
upperlimit3 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.5
lowerlimit3 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.6
upperlimit4 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.7
lowerlimit4 mandatory Integer32 .1.3.6.1.4.1.20916.1.1.3.8
Notifications / Traps (8)
NameOIDDescription
alarmstart1-t4 .1.3.6.1.4.1.20916.1.1.0.1
A alarmstart1 trap signifies that the current
temperature on sensor 1 is outside the 
defined high or low threshold.
tempager-snmp-trap .1.3.6.1.4.1.20916.1.1.0.2
A tempager-snmp-trap indicates that an alarm
condition has occurred on the sensor inidcated
by the alarmmessage variable.
alarmstart2-t4 .1.3.6.1.4.1.20916.1.1.0.3
A alarmstart2 trap signifies that the current
temperature on sensor 2 is outside the 
defined high or low threshold.
alarmclear2-t4 .1.3.6.1.4.1.20916.1.1.0.4
A alarmclear2 trap signifies that the current
temperature on sensor 2 has returned to a 
normal condition and is within the defined 
high or low threshold.
alarmstart3-t4 .1.3.6.1.4.1.20916.1.1.0.5
A alarmstart3 trap signifies that the current
temperature on sensor 3 is outside the 
defined high or low threshold.
alarmclear3-t4 .1.3.6.1.4.1.20916.1.1.0.6
A alarmclear3 trap signifies that the current
temperature on sensor 3 has returned to a 
normal condition and is within the defined 
high or low threshold.
alarmstart4-t4 .1.3.6.1.4.1.20916.1.1.0.7
A alarmstart4 trap signifies that the current
temperature on sensor 4 is outside the 
defined high or low threshold.
alarmclear4-t4 .1.3.6.1.4.1.20916.1.1.0.8
A alarmclear4 trap signifies that the current
temperature on sensor 4 has returned to a 
normal condition and is within the defined 
high or low threshold.