SUPERMICRO-G8261TS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
9
.1.3.6.1.4.1.10876.101.2.72.2.1 · 1 row entry · 9 columns
A table containing the configurable parameters of the delay module.
The table contains an entry per direction (forward/reverse)
fsG8261TsParamsEntry entry .1.3.6.1.4.1.10876.101.2.72.2.1.1
A list of objects that determine the delay to be introduced.
Indexes
fsG8261TsDirection
Column Syntax OID
fsG8261TsDirection
Direction on which the network disturbance to be introduced
Enumeration
Enumerated Values:
1forward
2reverse
.1.3.6.1.4.1.10876.101.2.72.2.1.1.1
fsG8261TsSwitchCount
No. of switches through which the packet should pass through in the
direction specified by fsG8261TsDirection.
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10876.101.2.72.2.1.1.2
fsG8261TsPacketSize
The size of the largest packet to be sent on the network,
specified in octets.
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10876.101.2.72.2.1.1.3
fsG8261TsLoad
Percentage of load or no. of packets of size specified by
fsG8261TsPacketSize to be transmitted for a duration specified by
fsG8261TsDuration.
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10876.101.2.72.2.1.1.4
fsG8261TsNetworkDisturbance
Percentage of noise to be introduced in the network.
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10876.101.2.72.2.1.1.5
fsG8261TsDuration
Duration for which network disturbance/load should be applied.
The units of duration is in seconds.
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10876.101.2.72.2.1.1.6
fsG8261TsFlowVariationFactor
Flow variation factor with which the load/noise should be introduced.
Noise/load can be introduced either as a constant flow or it can
applied as any of the following: 1. incremental flow
2.decremented flow
Enumerationr/w
Enumerated Values:
1constant
2incremental
3decremental
.1.3.6.1.4.1.10876.101.2.72.2.1.1.7
fsG8261TsFlowInterval
Interval in seconds till when the flow is applied.
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10876.101.2.72.2.1.1.8
fsG8261TsFrequency
Frequency at which the load specified by fsG8261TsLoad is applied on
the network.
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10876.101.2.72.2.1.1.9