STORMSHIELD-SYSTEM-MONITOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
21
.1.3.6.1.4.1.11256.1.10.5 · 1 row entry · 6 columns
Disk information
snsDiskEntry entry .1.3.6.1.4.1.11256.1.10.5.1
Disk information
Indexes
snsDiskEntryIndex
Column Syntax OID
snsDiskEntryIndex
Index of each disk in table
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.10.5.1.1
snsDiskEntryDiskName
Name of the disk
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.5.1.2
snsDiskEntrySmartResult
Result of the smart infos tests
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.5.1.3
snsDiskEntryIsRaid
Is the disk a member of a RAID array
Integer32
Constraints:
range: 0-1
.1.3.6.1.4.1.11256.1.10.5.1.4
snsDiskEntryRaidStatus
RAID Status
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.5.1.5
snsDiskEntryPosition
Disk Position
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.5.1.6
.1.3.6.1.4.1.11256.1.10.6 · 1 row entry · 3 columns
Power supply status of Firewall
snsPowerSupplyEntry entry .1.3.6.1.4.1.11256.1.10.6.1
Power supply information
Indexes
snsPowerSupplyIndex
Column Syntax OID
snsPowerSupplyIndex
Index of each line in table
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.10.6.1.1
snsPowerSupplyPowered
Is power supply powered by electricity ?
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.11256.1.10.6.1.2
snsPowerSupplyStatus
What is the status of the power supply ?
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.6.1.3
.1.3.6.1.4.1.11256.1.10.7 · 1 row entry · 2 columns
CPU status of Firewalls
snsCpuEntry entry .1.3.6.1.4.1.11256.1.10.7.1
CPU information
Indexes
snsCpuIndex
Column Syntax OID
snsCpuIndex
Index of each CPU in table
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.10.7.1.1
snsCpuTemp
Temperature in Celsius degree
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11256.1.10.7.1.2
.1.3.6.1.4.1.11256.1.10.8 · 1 row entry · 6 columns
Bypass status of Firewalls
snsBypassEntry entry .1.3.6.1.4.1.11256.1.10.8.1
Bypass information
Indexes
snsBypassIndex
Column Syntax OID
snsBypassIndex
Each line in the table
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.10.8.1.1
snsBypassI2CAddress
I2C Address of Bypass Device
Unsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11256.1.10.8.1.2
snsBypassSystemOff
System-off Bypass status
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.11256.1.10.8.1.3
snsBypassJustOn
Just-On Bypass status
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.11256.1.10.8.1.4
snsBypassRunTime
Run-Time Bypass status
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.11256.1.10.8.1.5
snsBypassWatchdog
Run-Time Watchdog Timer state
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.8.1.6
.1.3.6.1.4.1.11256.1.10.9 · 1 row entry · 4 columns
Fans status of Firewalls
snsFanEntry entry .1.3.6.1.4.1.11256.1.10.9.1
Fan information
Indexes
snsFanIndex
Column Syntax OID
snsFanIndex
Each line in the table
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.10.9.1.1
snsFanName
Name of the Fan
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.9.1.2
snsFanStatus
Status of the Fan
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.11256.1.10.9.1.3
snsFanRpm
Speed of the Fan
Unsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11256.1.10.9.1.4