.1.3.6.1.4.1.4515.1.3.13.1.1 · 1 row entry · 8 columns
The port loopback test table. This table controls the 
port loopback tests.
slTestsIfLoopEntry entry .1.3.6.1.4.1.4515.1.3.13.1.1.1
This entry is used to operate an port loopback test.
Indexes
slTestsIfLoopIfIndex
Column Syntax OID
slTestsIfLoopIfIndex
The Interface Index of the port that should be loopped back.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.4515.1.3.13.1.1.1.1
slTestsIfLoopDuration
The test duration in 1/10 Sec. The maximum allowed
duration is 1 hour. After this time the port configuration
returns to its original setting and the Agent automatically
deletes the entry from the table.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4515.1.3.13.1.1.1.2
slTestsIfLoopStatus
This variable is used to start or stop a loopback test.
In order to start a test the NMS should set the value to start(1).
If the test mode is toggle, the NMS should stop the test by setting the value
to stop(2).
In the…
Enumerationr/w
Enumerated Values:
1start
2stop
3fail
.1.3.6.1.4.1.4515.1.3.13.1.1.1.3
slTestsIfLoopType
The loopback type:
facility
The received signal at this interface is looped back
out through the corresponding transmitter in the return
direction.
terminal
The signal that is about to be transmitted is con…
Enumerationr/w
Enumerated Values:
1terminal
2facility
3prbs
4otnPrbs
.1.3.6.1.4.1.4515.1.3.13.1.1.1.5
slTestsIfLoopMode
The loopback mode:
timeout
In this mode the duration of the loopback is determined
by the slTestsIfLoopDuration object.
toggle
In this mode the loopback should be toggled explicitly
by the user.
Enumerationr/w
Enumerated Values:
1timeout
2toggle
.1.3.6.1.4.1.4515.1.3.13.1.1.1.6
slTestsIfLoopErrors
The prbs errors are counted only of the test succeeded.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4515.1.3.13.1.1.1.7
slTestsIfLoopResult
This variable is used for prbs test result indication.
Enumeration
Enumerated Values:
1success
2fail
.1.3.6.1.4.1.4515.1.3.13.1.1.1.8
slTestsIfLoopPassedSeconds
Number of seconds passed since the test started.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647