SIP-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
7
Rows
7
Columns
44
.1.3.6.1.2.1.10.31.1 · 1 row entry · 10 columns
This table contains SIP L3 parameters and
state variables, one entry per SIPL3 interface.
sipL3Entry entry .1.3.6.1.2.1.10.31.1.1
This list contains SIP L3 parameters and
state variables.
Indexes
sipL3Index
Column Syntax OID
sipL3Index
The value of this object identifies the SIP
L3 interface for which this entry contains
management information.
IfIndex
Textual Convention: IfIndex Integer32
.1.3.6.1.2.1.10.31.1.1.1
sipL3ReceivedIndividualDAs deprecated
The total number of individually addressed SIP
Level 3 PDUs received from the remote system
across the SNI. The total includes only
unerrored L3PDUs.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.2
sipL3ReceivedGAs deprecated
The total number of group addressed SIP Level 3
PDUs received from the remote system across the
SNI. The total includes only unerrored L3PDUs.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.3
sipL3UnrecognizedIndividualDAs deprecated
The number of SIP Level 3 PDUs received from the

remote system with invalid or unknown individual
destination addresses (Destination Address
Screening violations are not included). See SMDS
Subscription …
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.4
sipL3UnrecognizedGAs deprecated
The number of SIP Level 3 PDUs received from the
remote system with invalid or unknown group
addresses. (Destination Address Screening
violations are not included). See SMDS
Subscription MIB module.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.5
sipL3SentIndividualDAs deprecated
The number of individually addressed SIP Level 3
PDUs that have been sent by this system across the
SNI.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.6
sipL3SentGAs deprecated
The number of group addressed SIP L3PDUs that
have been sent by this system across the SNI.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.7
sipL3Errors deprecated
The total number of SIP Level 3 PDUs received
from the remote system that were discovered to
have errors (including protocol processing and bit
errors but excluding addressing-related errors)
and were discarded. Includ…
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.8
sipL3InvalidSMDSAddressTypes deprecated
The number of SIP Level 3 PDUs received from the
remote system that had the Source or Destination
Address_Type subfields, (the four most significant
bits of the 64 bit address field), not equal to
the value 1100 or 1110…
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.1.1.9
sipL3VersionSupport
A value which indicates the version(s) of SIP

that this interface supports. The value is a sum.
This sum initially takes the value zero. For each
version, V, that this interface supports, 2 raised
to (V…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.2.1.10.31.1.1.10
.1.3.6.1.2.1.10.31.2 · 1 row entry · 9 columns
This table contains SIP L2PDU parameters and
state variables, one entry per SIP L2 interface.
sipL2Entry entry .1.3.6.1.2.1.10.31.2.1
This list contains SIP L2 parameters and state
variables.
Indexes
sipL2Index
Column Syntax OID
sipL2Index
The value of this object identifies the SIP
interface for which this entry contains management
information.
IfIndex
Textual Convention: IfIndex Integer32
.1.3.6.1.2.1.10.31.2.1.1
sipL2ReceivedCounts
The number of SIP Level 2 PDUs received from the
remote system across the SNI. The total includes
only unerrored L2PDUs.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.2
sipL2SentCounts
The number of SIP Level 2 PDUs that have been
sent by this system across the SNI.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.3
sipL2HcsOrCRCErrors
The number of received SIP Level 2 PDUs that were
discovered to have either a Header Check Sequence
error or a Payload CRC violation.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.4
sipL2PayloadLengthErrors
The number of received SIP Level 2 PDUs that had
Payload Length errors that fall in the following
specifications:
- SSM L2_PDU payload length field value less
- than 28 octets or greater than 44 octets,
- BOM or COM L2_…
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.5
sipL2SequenceNumberErrors
The number of received SIP Level 2 PDUs that had
a sequence number within the L2PDU not equal to
the expected sequence number of the SMDS SS
receive process.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.6
sipL2MidCurrentlyActiveErrors
The number of received SIP Level 2 PDUs that are
BOMs for which an active receive process is
already started.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.7
sipL2BomOrSSMsMIDErrors
The number of received SIP Level 2 PDUs that are
SSMs with a MID not equal to zero or are BOMs with
MIDs equal to zero.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.8
sipL2EomsMIDErrors
The number of received SIP Level 2 PDUs that are
EOMs for which there is no active receive process
for the MID (i.e., the receipt of an EOM which
does not correspond to a BOM) OR the EOM has a MID
equal to zero.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.2.1.9
.1.3.6.1.2.1.10.31.3.1 · 1 row entry · 4 columns
This table contains SIP DS1 PLCP parameters and
state variables, one entry per SIP port.
sipDS1PLCPEntry entry .1.3.6.1.2.1.10.31.3.1.1
This list contains SIP DS1 PLCP parameters and
state variables.
Indexes
sipDS1PLCPIndex
Column Syntax OID
sipDS1PLCPIndex
The value of this object identifies the
interface for which this entry contains management
information.
IfIndex
Textual Convention: IfIndex Integer32
.1.3.6.1.2.1.10.31.3.1.1.1
sipDS1PLCPSEFSs
A DS1 Severely Errored Framing Second (SEFS) is a
count of one-second intervals containing one or
more SEF events. A Severely Errored Framing (SEF)
event is declared when an error in the A1 octet
and an error in the A2…
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.3.1.1.2
sipDS1PLCPAlarmState
This variable indicates if there is an alarm
present for the DS1 PLCP. The value
receivedFarEndAlarm means that the DS1 PLCP has
received an incoming Yellow Signal, the value
incomingLOF means that the DS1 PLCP has dec…
Enumeration
Enumerated Values:
1noAlarm
2receivedFarEndAlarm
3incomingLOF
.1.3.6.1.2.1.10.31.3.1.1.3
sipDS1PLCPUASs
The counter associated with the number of
Unavailable Seconds, as defined by TR-TSV-000773,
encountered by the PLCP.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.3.1.1.4
.1.3.6.1.2.1.10.31.3.2 · 1 row entry · 4 columns
This table contains SIP DS3 PLCP parameters and
state variables, one entry per SIP port.
sipDS3PLCPEntry entry .1.3.6.1.2.1.10.31.3.2.1
This list contains SIP DS3 PLCP parameters and
state variables.
Indexes
sipDS3PLCPIndex
Column Syntax OID
sipDS3PLCPIndex
The value of this object identifies the
interface for which this entry contains management
information.
IfIndex
Textual Convention: IfIndex Integer32
.1.3.6.1.2.1.10.31.3.2.1.1
sipDS3PLCPSEFSs
A DS3 Severely Errored Framing Second (SEFS) is a
count of one-second intervals containing one or
more SEF events. A Severely Errored Framing (SEF)
event is declared when an error in the A1 octet
and an error in the A2…
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.3.2.1.2
sipDS3PLCPAlarmState
This variable indicates if there is an alarm
present for the DS3 PLCP. The value
receivedFarEndAlarm means that the DS3 PLCP has
received an incoming Yellow Signal, the value
incomingLOF means that the DS3 PLCP has dec…
Enumeration
Enumerated Values:
1noAlarm
2receivedFarEndAlarm
3incomingLOF
.1.3.6.1.2.1.10.31.3.2.1.3
sipDS3PLCPUASs
The counter associated with the number of
Unavailable Seconds, as defined by TR-TSV-000773,
encountered by the PLCP.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.31.3.2.1.4
.1.3.6.1.2.1.10.31.4.1.1 · 1 row entry · 5 columns
The table of addressing information relevant to
this entity's IP addresses.
ipOverSMDSEntry entry .1.3.6.1.2.1.10.31.4.1.1.1
The addressing information for one of this
entity's IP addresses.
Indexes
ipOverSMDSIndex ipOverSMDSAddress
Column Syntax OID
ipOverSMDSIndex
The value of this object identifies the
interface for which this entry contains management
information.
IfIndex
Textual Convention: IfIndex Integer32
.1.3.6.1.2.1.10.31.4.1.1.1.1
ipOverSMDSAddress
The IP address to which this entry's addressing
information pertains.
SNMPv2-SMIIpAddress
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.2.1.10.31.4.1.1.1.2
ipOverSMDSHA
The SMDS Individual address of the IP station.
SMDSAddress
Textual Convention: SMDSAddress OctetString
Type Constraints:
range: 8
.1.3.6.1.2.1.10.31.4.1.1.1.3
ipOverSMDSLISGA
The SMDS Group Address that has been configured
to identify the SMDS Subscriber-Network Interfaces
(SNIs) of all members of the Logical IP Subnetwork
(LIS) connected to the network supporting SMDS.
SMDSAddress
Textual Convention: SMDSAddress OctetString
Type Constraints:
range: 8
.1.3.6.1.2.1.10.31.4.1.1.1.4
ipOverSMDSARPReq
The SMDS address (individual or group) to which
ARP Requests are to be sent.
SMDSAddress
Textual Convention: SMDSAddress OctetString
Type Constraints:
range: 8
.1.3.6.1.2.1.10.31.4.1.1.1.5
.1.3.6.1.2.1.10.31.6.1 · 1 row entry · 5 columns
A table that contains the latest occurrence of
the following syntactical SIP L3PDU errors:
          
- Destination Address Field Format Error,
The following pertains to the 60 least significant
bits of the 64 bit address field.  The 60 bits
contained in the address subfield can be used to
represent addresses up to 15 decimal digits.  Each
decimal digit shall be encoded into four bits
using Binary Coded Decimal (BCD), with the most
significant digit occurring left-most.  If not all
15 digits are required, then the remainder of this
field shall be padded on the right with bits set
to one.  An error is considered to have occurred:
a).  if the first four bits of the address
subfield are not BCD, OR b).  if the first four
bits of the address subfield are populated with
the country code value 0001, AND the 40 bits which
follow are not Binary Coded Decimal (BCD) encoded
values of the 10 digit addresses, OR the remaining
16 least significant bits are not populated with
1's, OR c).  if the address subfield is not
correct according to another numbering plan which
is dependent upon the carrier assigning the
numbers and offering SMDS.
          
- Source Address Field Format Error,
The description of this parameter is the same as
the description of the Destination Address Field
Format Error.
          
- Invalid BAsize Field Value,
An error is considered to have occurred when the
BAsize field of an SIP L3PDU contains a value less
that 32, greater than 9220 octets without the
CRC32 field present, greater than 9224 octets with
the CRC32 field present, or not equal to a
multiple of 4 octets,
- Invalid Header Extension Length Field Value,
An error is considered to have occurred when the
Header Extension Length field value is not equal
3.
          
- Invalid Header Extension - Element Length,
An error is considered to have occurred when the
Header Extension - Element Length is greater than
12.
          
- Invalid Header Extension - Version Element
Position, Length, or Value,
An error is considered to have occurred when a
Version element with Length=3, Type=0, and Value=1
does not appear first within the Header Extension,
or an element Type=0 appears somewhere other than
within the first three octets in the Header
Extension.
          
- Invalid Header Extension - Carrier Selection
Element Position, Length, Value or Format,
An error is considered to have occurred when a
Carrier Selection element does not appear second
within the Header Extension, if the Element Type
does not equal 1, the Element Length does not
equal 4, 6, or 8, the Element Value field is not
four BCD encoded decimal digits used in specifying
the Carrier Identification Code (CIC), or the
identified CIC code is invalid.
          
- Header Extension PAD Error
          
An error is considered to have occurred when the
Header Extension PAD is 9 octets in length, or if
the Header Extension PAD is greater than zero
          
octets in length and the Header Extension PAD does
not follow all Header Extension elements or does
not begin with at least one octet of all zeros.
          
- BEtag Mismatch Error,
An error is considered to have occurred when the
Beginning-End Tags in the SIP L3PDU header and
trailer are not equal.
          
- BAsize Field not equal to Length Field Error,
An error is considered to have occurred when the
value of the BAsize Field does not equal the value
of the Length Field.
          
- Incorrect Length Error, and
          
An error is considered to have occurred when the
the Length field value is not equal to the portion
of the SIP L3PDU which extends from the
Destination Address field up to and including the
CRC32 field (if present) or up to and including
the PAD field (if the CRC32 field is not present).
As an optional check, an error is considered to
have occurred when the length of a partially
received SIP L3PDU exceeds the BAsize value.
          
- MRI Timeout Error.
          
An error is considered to have occurred when the
elapsed time between receipt of BOM and
corresponding EOM exceeds the value of the MRI
(Message Receive Interval) for a particular
transport signal format.
          
An entry is indexed by interface number and error
type, and contains Source Address, Destination
Address and a timestamp. All these errors are
counted in the sipL3Errors counter.  When
sipL3PDUErrorTimeStamp is equal to zero, the
SipL3PDUErrorEntry does not contain any valid
information.
sipL3PDUErrorEntry entry .1.3.6.1.2.1.10.31.6.1.1
An entry in the service disagreement table.
Indexes
sipL3PDUErrorIndex sipL3PDUErrorType
Column Syntax OID
sipL3PDUErrorIndex
The value of this object identifies the
interface for which this entry contains management
information.
IfIndex
Textual Convention: IfIndex Integer32
.1.3.6.1.2.1.10.31.6.1.1.1
sipL3PDUErrorType
The type of error.
Enumeration
Enumerated Values:
1erroredDAFieldFormat
2erroredSAFieldFormat
3invalidBAsizeFieldValue
4invalidHdrExtLength
5invalidHdrExtElementLength
6invalidHdrExtVersionElementPositionLenthOrValue
7invalidHdrExtCarSelectElementPositionLenghtValueOrFormat
8hePADError
9beTagMismatch
10baSizeFieldNotEqualToLengthField
11incorrectLength
12mriTimeout
.1.3.6.1.2.1.10.31.6.1.1.2
sipL3PDUErrorSA
A rejected SMDS source address.
SMDSAddress
Textual Convention: SMDSAddress OctetString
Type Constraints:
range: 8
.1.3.6.1.2.1.10.31.6.1.1.3
sipL3PDUErrorDA
A rejected SMDS destination address.
SMDSAddress
Textual Convention: SMDSAddress OctetString
Type Constraints:
range: 8
.1.3.6.1.2.1.10.31.6.1.1.4
sipL3PDUErrorTimeStamp
The timestamp for the service disagreement. The
timestamp contains the value of sysUpTime at the
latest occurrence of this type of service
disagreement. See textual description under
sipL3PDUErrorTable for boundary co…
SNMPv2-TCTimeStamp
Textual Convention: SNMPv2-TCTimeStamp Unsigned32
.1.3.6.1.2.1.10.31.6.1.1.5
.1.3.6.1.2.1.36.1.1 · 1 row entry · 7 columns
The DXI table.
sipDxiEntry entry .1.3.6.1.2.1.36.1.1.1
An entry in the DXI table.
Indexes
Column Syntax OID
sipDxiCrc
The value of this object indicates the type
of Frame Checksum used by DXI. Current
choices include CCITT CRC16 or CRC32.
Enumeration
Enumerated Values:
1crc16
2crc32
.1.3.6.1.2.1.36.1.1.1.1
sipDxiOutDiscards
The number of outbound frames discarded
because of congestion.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.36.1.1.1.2
sipDxiInErrors
The number of inbound frames discarded
because of errors such as frame checksum
(CRC) violations,
non-integral number of octets, address
and control field violations, and frame
size errors.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.36.1.1.1.3
sipDxiInAborts
The number of inbound frames discarded
because of an abort bit sequence (1111111)
received before closing flag.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.36.1.1.1.4
sipDxiInTestFrames
The number of unerrored,
inbound Test frames received
(generally as part of Heart
Beat Poll procedure).
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.36.1.1.1.5
sipDxiOutTestFrames
The number of unerrored,
outbound Test frames sent
(generally as part of Heart
Beat Poll procedure).
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.36.1.1.1.6
sipDxiHbpNoAcks
The number of Heart Beat
Poll (HBP) No Ack timeouts.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.36.1.1.1.7