SIAE-UNIT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
14
.1.3.6.1.4.1.3373.1103.6.2 · 1 row entry · 14 columns
Table with Unit records.
unitRecord entry .1.3.6.1.4.1.3373.1103.6.2.1
Unit record.
Indexes
unitId
Column Syntax OID
unitId
This object is used as Index of the Unit Table.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3373.1103.6.2.1.1
unitExpectedType
Defines the expected unit type.
SNMPv2-TCAutonomousTyper/w
Textual Convention: SNMPv2-TCAutonomousType ObjectIdentifier
.1.3.6.1.4.1.3373.1103.6.2.1.2
unitActualType
Defines the real unit type actually present in the equipment
SNMPv2-TCAutonomousType
Textual Convention: SNMPv2-TCAutonomousType ObjectIdentifier
.1.3.6.1.4.1.3373.1103.6.2.1.3
unitLabel
ASCII string used to assign a name to the unit.
OctetString
Constraints:
range: 0-30
.1.3.6.1.4.1.3373.1103.6.2.1.4
unitFailAlarm
Unit Fail alarm status status with associated severity.
SIAE-ALARM-MIBAlarmStatus
Textual Convention: SIAE-ALARM-MIBAlarmStatus Enumeration
Type Values:
1cleared
2activeReportableStatus
3activeReportableWarning
4activeReportableMinor
5activeReportableMajor
6activeReportableCritical
.1.3.6.1.4.1.3373.1103.6.2.1.5
unitMissingAlarm
Unit Missing alarm status with associated severity.
SIAE-ALARM-MIBAlarmStatus
Textual Convention: SIAE-ALARM-MIBAlarmStatus Enumeration
Type Values:
1cleared
2activeReportableStatus
3activeReportableWarning
4activeReportableMinor
5activeReportableMajor
6activeReportableCritical
.1.3.6.1.4.1.3373.1103.6.2.1.6
unitNotRespondingAlarm
Unit Not Responding alarm status with associated severity.
SIAE-ALARM-MIBAlarmStatus
Textual Convention: SIAE-ALARM-MIBAlarmStatus Enumeration
Type Values:
1cleared
2activeReportableStatus
3activeReportableWarning
4activeReportableMinor
5activeReportableMajor
6activeReportableCritical
.1.3.6.1.4.1.3373.1103.6.2.1.7
unitHwMismatchAlarm
Unit type Mismatch alarm status with associated severity.
SIAE-ALARM-MIBAlarmStatus
Textual Convention: SIAE-ALARM-MIBAlarmStatus Enumeration
Type Values:
1cleared
2activeReportableStatus
3activeReportableWarning
4activeReportableMinor
5activeReportableMajor
6activeReportableCritical
.1.3.6.1.4.1.3373.1103.6.2.1.8
unitSwMismatchAlarm
Unit with Sw Release Mismatch alarm status with associated severity.
SIAE-ALARM-MIBAlarmStatus
Textual Convention: SIAE-ALARM-MIBAlarmStatus Enumeration
Type Values:
1cleared
2activeReportableStatus
3activeReportableWarning
4activeReportableMinor
5activeReportableMajor
6activeReportableCritical
.1.3.6.1.4.1.3373.1103.6.2.1.9
unitHwEdition
ASCII string used to identify Hw edition of the unit.
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.3373.1103.6.2.1.10
unitPartNumber
ASCII string to identify the Part Number of the unit.
OctetStringr/w
Constraints:
range: 0-30
.1.3.6.1.4.1.3373.1103.6.2.1.11
unitParentPartNumber
ASCII string to identify the parent Part Number of the unit.
OctetStringr/w
Constraints:
range: 0-30
.1.3.6.1.4.1.3373.1103.6.2.1.12
unitParentSerialNumber
ASCII string to identify parent Serial Number of the unit.
OctetStringr/w
Constraints:
range: 0-30
.1.3.6.1.4.1.3373.1103.6.2.1.13
unitRowStatus
Status of this row of unitTable.
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.4.1.3373.1103.6.2.1.14