SDEVICE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
33
inputmeasuresTable
table.1.3.6.1.4.1.31034.2.8
·
1 row entry
·
13 columns
This table contains all measures related to the measured inputs of the DEVICE. Note: either 1 or 3 channels, depending on number of phases measured.
The record containing the registers for the channel selected
by channelIndex.
by channelIndex.
Indexes
channelIndex6
| Column | Syntax | OID |
|---|---|---|
|
channelIndex6
The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
Integer32 Constraints: range: 1-48 |
.1.3.6.1.4.1.31034.2.8.1.1 |
|
kWhTotalI
Either the only phase in a single phase measurement; or one of
the three phases in a multiphase measurement. |
KiloWattHour Textual Convention: KiloWattHour Integer32 |
.1.3.6.1.4.1.31034.2.8.1.2 |
|
kWhSubtotalI
kWh subtotal register of the only phase in a single phase
measurement; or one of three phases in a multiphase measurement. Reset to zero with [rsimks]. |
KiloWattHour Textual Convention: KiloWattHour Integer32 |
.1.3.6.1.4.1.31034.2.8.1.3 |
|
powerFactorI
The effective power factor in percent.
|
DeciPowerFactor Textual Convention: DeciPowerFactor Integer32 |
.1.3.6.1.4.1.31034.2.8.1.4 |
|
actualCurrentI
Actual apparent, RMS current.
|
DeciAmps Textual Convention: DeciAmps Integer32 |
.1.3.6.1.4.1.31034.2.8.1.5 |
|
peakCurrentI
Peak apparent, RMS current; highest value since last reset of
the alerts. |
DeciAmps Textual Convention: DeciAmps Integer32 |
.1.3.6.1.4.1.31034.2.8.1.6 |
|
actualVoltageI
The actual voltage.
|
DeciVolts Textual Convention: DeciVolts Integer32 |
.1.3.6.1.4.1.31034.2.8.1.7 |
|
minVoltageI
RMS voltage dip; lowest value since reset of alerts.
|
DeciVolts Textual Convention: DeciVolts Integer32 |
.1.3.6.1.4.1.31034.2.8.1.8 |
|
powerVAI
Power value calculated, not in data model of device.
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.31034.2.8.1.9 |
|
powerWattI
Power value calculated by the gateway, not in data model of
device. |
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.31034.2.8.1.10 |
|
maxInletAmps
Maximum current per input phase in A; should last at least
[stpkdr] MilliSeconds before triggering an alert. |
DeciAmpsr/w Textual Convention: DeciAmps Integer32 |
.1.3.6.1.4.1.31034.2.8.1.11 |
|
inputCTratio
The multiplier to use in case of use of /5 current
transformers. Defaults to 1. |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.31034.2.8.1.12 |
|
inputName
User configurable naming of inputs or phases. Useful if
channels are used to measure branches.. |
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.31034.2.8.1.13 |
outletsTable
table.1.3.6.1.4.1.31034.2.9
·
1 row entry
·
2 columns
This table contains the customer specific settings, determining toutlestablehe behaviour of the DEVICE.
The record containing the registers forthe channel selected by
channelIndex.
channelIndex.
Indexes
channelIndex4
| Column | Syntax | OID |
|---|---|---|
|
channelIndex4
The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
Integer32 Constraints: range: 1-48 |
.1.3.6.1.4.1.31034.2.9.1.1 |
|
outletName
User configurable naming of individual outlets. Useful to
distinguish outlets based on customer or device name. |
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.31034.2.9.1.2 |
outputmeasuresTable
table.1.3.6.1.4.1.31034.2.10
·
1 row entry
·
9 columns
This table contains all measures related to the measured outputs of the DEVICE. Note: up to 48 channels, depending on number of measured outlets.
The record containing the registers for the channel selected
by channelIndex.
by channelIndex.
Indexes
channelIndex7
| Column | Syntax | OID |
|---|---|---|
|
channelIndex7
The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
Integer32 Constraints: range: 1-48 |
.1.3.6.1.4.1.31034.2.10.1.1 |
|
kWhTotalO
Total kWh of selected output.
|
KiloWattHour Textual Convention: KiloWattHour Integer32 |
.1.3.6.1.4.1.31034.2.10.1.2 |
|
kWhSubtotalO
kWh subtotal register of selected output. Reset to zero with
[rsomks]. |
KiloWattHour Textual Convention: KiloWattHour Integer32 |
.1.3.6.1.4.1.31034.2.10.1.3 |
|
powerFactorO
Power factor of output.
|
DeciPowerFactor Textual Convention: DeciPowerFactor Integer32 |
.1.3.6.1.4.1.31034.2.10.1.4 |
|
actualCurrentO
Actual apparent, RMS current.
|
DeciAmps Textual Convention: DeciAmps Integer32 |
.1.3.6.1.4.1.31034.2.10.1.5 |
|
peakCurrentO
Peak apparent, RMS current; highest value since last reset of
alerts. |
DeciAmps Textual Convention: DeciAmps Integer32 |
.1.3.6.1.4.1.31034.2.10.1.6 |
|
actualVoltageO
Actual voltage on output.
|
DeciVolts Textual Convention: DeciVolts Integer32 |
.1.3.6.1.4.1.31034.2.10.1.7 |
|
maxOutletAmps
Maximum current per outlet in A; should last at least [stpkdr]
MilliSeconds before triggering an alert. |
DeciAmpsr/w Textual Convention: DeciAmps Integer32 |
.1.3.6.1.4.1.31034.2.10.1.8 |
|
outputCTratio
The multiplier to use in case of use of /5 current
transformers. Defaults to 1. |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.31034.2.10.1.9 |
switchedoutletsTable
table.1.3.6.1.4.1.31034.2.11
·
1 row entry
·
5 columns
This table contains the current status of switchable DEVICE's.
The record containing the registers for the channel selected
by channelIndex.
by channelIndex.
Indexes
channelIndex5
| Column | Syntax | OID |
|---|---|---|
|
channelIndex5
The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
Integer32 Constraints: range: 1-48 |
.1.3.6.1.4.1.31034.2.11.1.1 |
|
currentState
The actual state of the outlet relays. The hardware will
contain max 48 outlets. Writing is only effective after setting [swounl]. |
Integer32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.31034.2.11.1.2 |
|
scheduled
A one indicates pending activity; the switch delay has not yet
expired. |
Integer32 Constraints: range: 0-1 |
.1.3.6.1.4.1.31034.2.11.1.3 |
|
unlock
Setting the value to one will release the safety for this
outlet for a couple seconds; switching and rebooting are then temporarily enabled. |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.31034.2.11.1.4 |
|
individualOutletDelay
Delay before an individual outlet switches on at power-up in
Seconds. |
Secondsr/w Textual Convention: Seconds Integer32 |
.1.3.6.1.4.1.31034.2.11.1.5 |
sensorTable
table.1.3.6.1.4.1.31034.2.12
·
1 row entry
·
4 columns
This table contains the environmental measurements. As well internal temperature as external temperature probes.
The record containing the registers for the channel selected
by channelIndex.
by channelIndex.
Indexes
channelIndex8
| Column | Syntax | OID |
|---|---|---|
|
channelIndex8
The channel. Its value ranges between 1 and 48, depending on
the number of channels, usually 1. |
Integer32 Constraints: range: 1-48 |
.1.3.6.1.4.1.31034.2.12.1.1 |
|
sensorType
Type of connected sensor, either T, H or I for respectively
Temperature (C), Humidity (%) or dry switch contact |
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.31034.2.12.1.2 |
|
sensorValue
Value of connected sensor
|
DeciValue Textual Convention: DeciValue Integer32 |
.1.3.6.1.4.1.31034.2.12.1.3 |
|
sensorName
User definable name for sensors.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.31034.2.12.1.4 |