SCTE-HMS-PROPERTY-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
15
.1.3.6.1.4.1.5591.1.1.1 · 1 row entry · 8 columns
A table that contains information about NE parameter properties.
propertyEntry entry .1.3.6.1.4.1.5591.1.1.1.1
A list of information about each property.

The OID suffix for an entry in this table is constructed by
appending the length of parameterOID and then the components
of parameterOID to identify an instance.
Indexes
parameterOID
Column Syntax OID
parameterOID
Index into propertyTable. This is the OID of the parameter
whose property is being accessed.

Example: OID of power supply the first instance of the
psInputVoltage is 1.3.6.1.4.1.5591…
ObjectIdentifier .1.3.6.1.4.1.5591.1.1.1.1.1
alarmEnable
Alarm enable bit mask. A 1 in a bit position indicates the alarm
is enabled.
Bit 0 = LOLO (Major alarm)
Bit 1 = LO (Minor alarm)
Bit 2 = HI (Minor alarm)
Bit 3 = HIHI (Major alarm)
Bit 4 = Unused, must be z…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5591.1.1.1.1.2
currentAlarmState
The object contains the current alarm status associated with this property entry.
Enumeration
Enumerated Values:
1casNominal
2casHIHI
3casHI
4casLO
5casLOLO
.1.3.6.1.4.1.5591.1.1.1.1.3
analogAlarmHIHI
The HIHI (Major alarm) alarm occurs at this value. The unit associated with
this property is the same as that of the parameter addressed.
This object should be kept in NV memory.

Some devices only require…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.1.1.1.4
analogAlarmHI
The HI (Minor alarm)alarm occurs at this value. The unit associated with
this property is the same as that of the parameter addressed.
This object should be kept in NV memory.

Some devices only require 16…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.1.1.1.5
analogAlarmLO
The LO (Minor alarm) alarm occurs at this value. The unit associated with
this property is the same as that of the parameter addressed.
This object should be kept in NV memory.

Some devices only require 1…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.1.1.1.6
analogAlarmLOLO
The LOLO (Major alarm)alarm occurs at this value. The unit associated with
this property is the same as that of the parameter addressed.
This object should be kept in NV memory.

Some devices only require …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.1.1.1.7
analogAlarmDeadband
Deadband for prevention of alarm oscillation. An alarm does
not return to normal until the value either
(a) passes the original threshold by this amount in
the opposite direction of the alarm, or
(b) alarm is disabled.…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.1.1.1.9
.1.3.6.1.4.1.5591.1.1.2 · 1 row entry · 3 columns
A table that contains information about NE parameter properties
that have alarms currently active.
currentAlarmEntry entry .1.3.6.1.4.1.5591.1.1.2.1
A list of information about each property with an alarm that is
currently active.

The OID suffix for an entry in this table is constructed by
appending the length of currentAlarmOID and then the components …
Indexes
currentAlarmOID
Column Syntax OID
currentAlarmOID
This is the OID of the alarmed object whose current value makes
an alarm active.

In the case of the alarmed analog object, the value of
this object is equal to the value of the index parameterOID
of th…
ObjectIdentifier .1.3.6.1.4.1.5591.1.1.2.1.1
currentAlarmAlarmState
The object contains the current alarm state of the associated
property entry.
Enumeration
Enumerated Values:
2caasHIHI
3caasHI
4caasLO
5caasLOLO
6caasDiscreteMajor
7caasDiscreteMinor
.1.3.6.1.4.1.5591.1.1.2.1.2
currentAlarmAlarmValue
Value that caused this alarm.

Some devices only require 16 bit integer or smaller and therefore only support 16 bit (or smaller)
values.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5591.1.1.2.1.3
.1.3.6.1.4.1.5591.1.1.3 · 1 row entry · 4 columns
A table that contains information about NE parameter properties.
discretePropertyEntry entry .1.3.6.1.4.1.5591.1.1.3.1
A list of information about each property.

The OID suffix for an entry in this table is constructed by
appending the length of discreteParameterOID and then the components
of discreteParameterOID to identi…
Indexes
discreteParameterOID discreteAlarmValue
Column Syntax OID
discreteParameterOID
First index into discretePropertyTable. This is the OID of the parameter
whose property is being accessed.

Example: OID of psTamper fo…
ObjectIdentifier .1.3.6.1.4.1.5591.1.1.3.1.1
discreteAlarmValue
Second index into the discretePropertyTable.
When the parameter, specified by discreteParameterOID has this value,
an alarm will occur.

Some devices only require 16 bit integer or smaller and therefore …
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.5591.1.1.3.1.2
discreteAlarmEnable
When set to enable(2 or 3), alarm processing for this property is enabled. When set to
disable(1), alarm processing for this property is disabled. No entries into the
alarmLogTable nor traps are permitted due to this …
Enumerationr/w
Enumerated Values:
1disable
2enableMajor
3enableMinor
.1.3.6.1.4.1.5591.1.1.3.1.3
discreteAlarmState
This object contains the current alarm state for this discrete property entry.
Enumeration
Enumerated Values:
1dasNominal
6dasDiscreteMajor
7dasDiscreteMinor
.1.3.6.1.4.1.5591.1.1.3.1.4