POWER-ETHERNET-MIB

        The MIB module for managing Power Source Equipment
(PSE) working according to the IEEE 802.af Powered
Ethernet (DTE Power via MDI) standard.
        
 The following terms are used throughout this
 MIB module.  For complete formal definitions,
 the IEEE 802.3 standards should be consulted
 wherever possible:
        
 Group - A recommended, but optional, entity
 defined by the IEEE 802.3 management standard,
 in order to support a modular numbering scheme.
 The classical example allows an implementor to
 represent field-replaceable units as groups of
 ports, with the port numbering matching the
 modular hardware implementation.
        
Port - This entity identifies the port within the group
for which this entry contains information.  The numbering
scheme for ports is implementation specific.
        
Copyright (c) The Internet Society (2003).  This version
of this MIB module is part of RFC 3621; See the RFC
itself for full legal notices.
    
powerEthernetMIB 1.3.6.1.2.1.105
Imported Objects
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-CONF MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMI Counter32 Gauge32 Integer32 mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TC TruthValue
Objects (38)
powerEthernetMIB .1.3.6.1.2.1.105
pethNotifications .1.3.6.1.2.1.105.0
pethObjects .1.3.6.1.2.1.105.1
pethPsePortTable .1.3.6.1.2.1.105.1.1
pethPsePortEntry pethPsePortGroupIndexpethPsePortIndex .1.3.6.1.2.1.105.1.1.1
pethPsePortGroupIndex Integer32 .1.3.6.1.2.1.105.1.1.1.1
pethPsePortPowerClassifications Enumeration .1.3.6.1.2.1.105.1.1.1.10
pethPsePortInvalidSignatureCounter SNMPv2-SMICounter32 .1.3.6.1.2.1.105.1.1.1.11
pethPsePortPowerDeniedCounter SNMPv2-SMICounter32 .1.3.6.1.2.1.105.1.1.1.12
pethPsePortOverLoadCounter SNMPv2-SMICounter32 .1.3.6.1.2.1.105.1.1.1.13
pethPsePortShortCounter SNMPv2-SMICounter32 .1.3.6.1.2.1.105.1.1.1.14
pethPsePortActualPower Integer32 .1.3.6.1.2.1.105.1.1.1.15
pethPsePortPowerAccuracy Integer32 .1.3.6.1.2.1.105.1.1.1.16
pethPsePortCumulativeEnergy SNMPv2-SMICounter32 .1.3.6.1.2.1.105.1.1.1.17
pethPsePortIndex Integer32 .1.3.6.1.2.1.105.1.1.1.2
pethPsePortAdminEnable r/w SNMPv2-TCTruthValue .1.3.6.1.2.1.105.1.1.1.3
pethPsePortPowerPairsControlAbility SNMPv2-TCTruthValue .1.3.6.1.2.1.105.1.1.1.4
pethPsePortPowerPairs r/w Enumeration .1.3.6.1.2.1.105.1.1.1.5
pethPsePortDetectionStatus Enumeration .1.3.6.1.2.1.105.1.1.1.6
pethPsePortPowerPriority r/w Enumeration .1.3.6.1.2.1.105.1.1.1.7
pethPsePortMPSAbsentCounter SNMPv2-SMICounter32 .1.3.6.1.2.1.105.1.1.1.8
pethPsePortType r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.2.1.105.1.1.1.9
pethMainPseObjects .1.3.6.1.2.1.105.1.3
pethMainPseTable .1.3.6.1.2.1.105.1.3.1
pethMainPseEntry pethMainPseGroupIndex .1.3.6.1.2.1.105.1.3.1.1
pethMainPseGroupIndex Integer32 .1.3.6.1.2.1.105.1.3.1.1.1
pethMainPsePower WattsUnsigned32 .1.3.6.1.2.1.105.1.3.1.1.2
pethMainPseOperStatus Enumeration .1.3.6.1.2.1.105.1.3.1.1.3
pethMainPseConsumptionPower WattsSNMPv2-SMIGauge32 .1.3.6.1.2.1.105.1.3.1.1.4
pethMainPseUsageThreshold r/w %Integer32 .1.3.6.1.2.1.105.1.3.1.1.5
pethNotificationControl .1.3.6.1.2.1.105.1.4
pethNotificationControlTable .1.3.6.1.2.1.105.1.4.1
pethNotificationControlEntry pethNotificationControlGroupIndex .1.3.6.1.2.1.105.1.4.1.1
pethNotificationControlGroupIndex Integer32 .1.3.6.1.2.1.105.1.4.1.1.1
pethNotificationControlEnable r/w SNMPv2-TCTruthValue .1.3.6.1.2.1.105.1.4.1.1.2
pethConformance .1.3.6.1.2.1.105.2
pethCompliances .1.3.6.1.2.1.105.2.1
pethGroups .1.3.6.1.2.1.105.2.2
Notifications / Traps (3)
NameOIDDescription
pethPsePortOnOffNotification .1.3.6.1.2.1.105.0.1
This Notification indicates if Pse Port is delivering or
not power to the PD.  This Notification SHOULD be sent on
every status change except in the searching mode.
At least 500 msec must elapse between notifications
being emitted by the same object instance.
pethMainPowerUsageOnNotification .1.3.6.1.2.1.105.0.2
This Notification indicate PSE Threshold usage
indication is on, the usage power is above the
threshold.  At least 500 msec must elapse between
notifications being emitted by the same object
instance.
pethMainPowerUsageOffNotification .1.3.6.1.2.1.105.0.3
This Notification indicates PSE Threshold usage indication
off, the usage power is below the threshold.
At least 500 msec must elapse between notifications being
emitted by the same object instance.