PDN-DS1CONFIG-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
11
.1.3.6.1.4.1.1795.2.24.2.6.5.1.1
·
1 row entry
·
4 columns
The Paradyne DS1 Interface Test Table.
An entry in the Paradyne DS1 Interface Test Table.
Indexes
devDS1TestIfIndex devDS1TestType
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
devDS1TestIfIndex
mandatory
The index value which uniquely identifies the
interface for which this entry contains information on interface tests. The interface identified by a particular value of this index is the same interface as identified by … |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
devDS1TestType
mandatory
The index value which uniquely identifies the test for
which this entry contains information. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
devDS1TestControl
mandatory
A control variable used to start and stop operator-
initiated interface tests. Writing idle(1) to the test table entry terminates the specified test for the interface associated with the entry. Writing running(2) acti… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
devDS1TestArgument
mandatory
Any argument required by the test being executed.
|
OctetStringr/w Constraints: range: 0-255 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.1.1.4 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.2
·
1 row entry
·
4 columns
The Paradyne Device Monitor Test Pattern Result Table.
An entry in the Paradyne Device Monitor Test
Pattern Result Table.
Pattern Result Table.
Indexes
devDS1MonResultIfIndex devDS1MonResultTestType
| Column | Syntax | OID | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
devDS1MonResultIfIndex
mandatory
The index value which uniquely identifies the
interface for which this entry contains information on the result of the monitor test pattern request. The interface identified by a particular value of this index is the sa… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.1 |
||||||||||||||||||||||||||
|
devDS1MonResultTestType
mandatory
The index value which uniquely identifies the test for
which this entry contains information. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.2 |
||||||||||||||||||||||||||
|
devDS1MonResultCode
mandatory
This object contains a code for more specific information
on the test pattern monitoring result. A value of none(1) indicates that no further information is available. inSyncNoBitErrors(2) notes that the monitor patter… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.3 |
||||||||||||||||||||||||||
|
devDS1MonResultErrorCount
mandatory
The number of bit errors detected in the received
monitoring test pattern. The error count is updated once every second. The error count does not increment during periods when the pattern is not synchronized, or once … |
RFC1155-SMIGauger/w Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.2.1.4 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.3
·
1 row entry
·
3 columns
The Paradyne Device Send Test Pattern Control Table.
An entry in the Paradyne Device Send Test
Pattern Control Table.
Pattern Control Table.
Indexes
devDS1SendControlIfIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
devDS1SendControlIfIndex
mandatory
The index value which uniquely identifies the
interface for which this entry contains information on the result of the monitor test pattern request. The interface identified by a particular value of this index is the sa… |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.1 |
||||
|
devDS1SendControlInjectErr
mandatory
Setting this object to inject(2) will inject one error
in the data pattern being sent. If no pattern is being sent, the agent will return BAD VALUE. Reading this value will always return noOp(1). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.2 |
||||
|
devDS1SendControlErrorCount
mandatory
The number of bit errors injected into the test pattern
being sent. The maximum value of this object is 99,999. |
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1795.2.24.2.6.5.1.3.1.3 |