PDN-DIAGNOSTICS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
7
Rows
7
Columns
70
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1
·
1 row entry
·
9 columns
This table contains input and results of a packet loopback test. This table is indexed by ifIndex. This is a interface related test. There can be only one test running per interface. This table should be used in conjunction with ifTestTable(Rfc 1573) with all the semantics of ifTestTable.
An entry containing objects for test input and result
for packet loopback test
for packet loopback test
Indexes
RFC1213-MIBifIndex
| Column | Syntax | OID |
|---|---|---|
|
loopbackTestInputNumCycles
mandatory
This object corresponds the number of cycles the test
to be run for. One cycle corresponds to a 15 second interval. The default value for this object is 40. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.1 |
|
loopbackTestResultsPktsSent
mandatory
This object corresponds to the number of packets sent
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.2 |
|
loopbackTestResultsPktsRcvdOK
mandatory
This object corresponds to the number of packets which were received
without any error |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.3 |
|
loopbackTestResultsPktsRcvdErr
mandatory
This object corresponds to the number of packets which were received
with errors |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.4 |
|
loopbackTestResultsPktsNotRcvd
mandatory
This object corresponds to the number of packets which were sent
but not received |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.5 |
|
loopbackTestResultsPktErrorRate
mandatory
Reflects the error rate of the loopback test. this string
will represent a floating point number of the form [ErrRate][eE][+-][ErrRateBase] where ErrRate and ErrRateBase are integers. In Other Words ErrRate * [10^ -E… |
OctetString Constraints: range: 1-32 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.6 |
|
loopbackTestResultsErrSecs
mandatory
This object corresponds to the number of errored seconds
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.7 |
|
loopbackTestResultsSvrErrSecs
mandatory
This object corresponds to the number of severely errored seconds
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.8 |
|
loopbackTestResultsElpTime
mandatory
This object corresponds to the number of seconds elapsed since the
start of the test. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.9 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2
·
1 row entry
·
17 columns
This table contains the objects for Bit Error Rate Test. This table is indexed by ifIndex.
An Entry containing objects of BERT.
Indexes
RFC1213-MIBifIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
ifBERTTestDuration
mandatory
This object represents the test duration in seconds.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.1 |
||||
|
ifBERTElapsedTime
mandatory
This object represents the elapsed time in seconds.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.2 |
||||
|
ifBERTDownSyncUP
mandatory
This object indicates whether Downstream sync is enabled .
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.3 |
||||
|
ifBERTUpSyncUP
mandatory
This object indicates whether upstream sync is enabled.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.4 |
||||
|
ifBERTSegmentsSent
mandatory
This object represents the number of segments sent during the test
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.5 |
||||
|
ifBERTDownMBitsRcvd
mandatory
This represents the number of million bits rcvd downstream.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.6 |
||||
|
ifBERTUpMBitsRcvd
mandatory
This represents the number of million bits rcvd upstream.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.7 |
||||
|
ifBERTDownBitErrDetected
mandatory
This represents the number of bit errors detected downstream.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.8 |
||||
|
ifBERTUpBitErrDetected
mandatory
This represents the number of bit errors detected upstream.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.9 |
||||
|
ifBERTDownBitErrRate
mandatory
This string will represent a floating point number of the
form [Er rRate] [eE] [+-] [ErrRatebase] where ErrTare and errRateBase are integers. |
OctetString Constraints: range: 1-32 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.10 |
||||
|
ifBERTUpBitErrRate
mandatory
This object reflects the error rate of BERT in Upstream direction.
This string will represent a floating point number of the form [ErrRate] [eE] [+-] [ErrRatebase] where ErrTare and errRateBase are integers. |
OctetString Constraints: range: 1-32 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.11 |
||||
|
ifBERTDownErroredSecs
mandatory
This represents number of errored seconds downstream. Errored second
is a second in which there is at least 1 block error. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.12 |
||||
|
ifBERTUpErroredSecs
mandatory
This represents number of errored seconds upstream.
Errored second is a second in which there is at least 1 block error. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.13 |
||||
|
ifBERTDownLineRate
mandatory
This represents the downstream line rate in KBPS
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.14 |
||||
|
ifBERTUpLineRate
mandatory
This represents the Upstream line rate in KBPS
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.15 |
||||
|
ifBERTDownMargin
mandatory
This represents the Downstream margin in decibels (DB).
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.16 |
||||
|
ifBERTUpMargin
mandatory
This represents the upstream margin in decibels (DB).
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.17 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3
·
1 row entry
·
10 columns
This table contains the objects for Block Error Rate Test (BLERT). This table is indexed by ifIndex.
An Entry containing objects of BLERT.
Indexes
RFC1213-MIBifIndex
| Column | Syntax | OID |
|---|---|---|
|
ifBLERTTestDuration
mandatory
This object represents the test duration in seconds.
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.1 |
|
ifBLERTElapsedTime
mandatory
This object represents the elapsed time in seconds since the test started.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.2 |
|
ifBLERTTxSeqCount
mandatory
This object indicates the next Tx sequence.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.3 |
|
ifBLERTRxSeqCount
mandatory
This object indicates the next Rx sequence.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.4 |
|
ifBLERTRxGoodFrames
mandatory
This object indicates the number of good frames received.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.5 |
|
ifBLERTTxGoodFrames
mandatory
This object indicates the number of good frames transmitted.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.6 |
|
ifBLERTRxBadFrames
mandatory
This object indicates the number of bad frames received.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.7 |
|
ifBLERTTxBadFrames
mandatory
This object indicates the number of bad frames transmitted.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.8 |
|
ifBLERTDnLineRate
mandatory
This object indicates the downstream line rate.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.9 |
|
ifBLERTUpLineRate
mandatory
This object indicates the upstream line rate.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.10 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.5
·
1 row entry
·
6 columns
This table controls all the application tests. It defines a test type, starts a test, and clears a test.
An entry containing objects for invoking application based tests
Indexes
applTestId
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
applTestId
mandatory
A unique ID to identify each application test.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.1 |
||||||||||||
|
applTestType
mandatory
This object defines the application test type.
|
SNMPv2-TCAutonomousTyper/w Textual Convention: SNMPv2-TCAutonomousType ObjectIdentifier |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.2 |
||||||||||||
|
applTestStatus
mandatory
This object shows the current status of an application test.
none - indicates waiting for test parameters. inProgress - indicates the test is in process. success - indicates the test is completed. failed … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.3 |
||||||||||||
|
applTestErrorCode
mandatory
This object shows the reason for a test failure.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.4 |
||||||||||||
|
applTestOwner
mandatory
The network manager who has started the test
|
OctetStringr/w Constraints: range: 1-40 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.5 |
||||||||||||
|
applTestRowStatus
mandatory
This object is used to create a new row or delete an
existing row for an application test. |
SNMPv2-TCRowStatusr/w Textual Convention: SNMPv2-TCRowStatus EnumerationType Values:
|
.1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.6 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6
·
1 row entry
·
13 columns
This table contains objects which allow network manager to ping a destination.
This table contains the input parameters for a ping test
and the results of the ping test.
and the results of the ping test.
Indexes
applPingTestId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
applPingTestId
mandatory
A unique ID to identify each application test.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.1 |
||||||
|
applPingTestIpAddress
mandatory
The IP address to be pinged.
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.2 |
||||||
|
applPingTestSourceIpAddr
mandatory
The Source IP address where we are pinging from.
This is an optional object for some devices. See operational specification for its use. |
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.3 |
||||||
|
applPingTestPacketSize
mandatory
This object corresponds to the size of the packet (in bytes)
which will be sent during the Ping test. The default value for this object is 64 bytes |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.4 |
||||||
|
applPingTestTimeout
mandatory
This object corresponds to a timeout value (in seconds)
between Pings. The default value for this object is 5 seconds |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.5 |
||||||
|
applPingTestMaxPings
mandatory
This object corresponds to the maximum number of times the
device should Ping for the destination. The default value for this object is 10 |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.6 |
||||||
|
applPingTestPktsSent
mandatory
This object corresponds to the total number of packets sent.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.7 |
||||||
|
applPingTestPktsRecv
mandatory
This object corresponds to the total number of packets received
without error |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.8 |
||||||
|
applPingTestMinTime
mandatory
The minimum round trip time.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.9 |
||||||
|
applPingTestMaxTime
mandatory
The maximum round trip time.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.10 |
||||||
|
applPingTestAvgTime
mandatory
The average round trip time.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.11 |
||||||
|
applPingTestDomain
mandatory
This object specifies the destination ip address's domain.
The Default is service domain. Not allowed if source ip address is entered. This is an optional object for some devices. See operational specification its use. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.12 |
||||||
|
applPingTestIfIndex
mandatory
This object specifies the interface over which the ping test will
take place. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.13 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7
·
1 row entry
·
8 columns
This table contains objects which allow network manager to enter the parameters of a traceroute test.
This table contains the input parameters for a traceroute test.
Indexes
applTracerouteTestId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
applTracerouteTestId
mandatory
A unique ID to identify each application test.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.1 |
||||||
|
applTracerouteIpAddress
mandatory
The destination IP address of a traceroute test.
|
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.2 |
||||||
|
applTracerouteSourceIpAddr
mandatory
The source IP address of where the traceroute test started.
This is an optional object for some devices. See operational specification for its use. |
RFC1155-SMIIpAddressr/w Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.3 |
||||||
|
applTraceroutePktsSize
mandatory
This object corresponds to the size of the packet (in bytes)
which will be sent during the traceroute test. Please refer to product specific documentation for the default values supported |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.4 |
||||||
|
applTracerouteTimeout
mandatory
This object corresponds to a timeout value (in seconds)
of a traceroute test. The default value for this object is 5 seconds |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.5 |
||||||
|
applTracerouteMaxHops
mandatory
This object corresponds to the maximum number of hops
to reach the destination. The default value for this object is device specific. See Operational Specifications |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.6 |
||||||
|
applTracerouteDomain
mandatory
This object specifies the destination ip address's domain.
The Default is service domain. Not allowed if source ip address is entered. This is an optional object for some devices. See operational specification its use. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.7 |
||||||
|
applTracerouteIfIndex
mandatory
This object specifies the interface over which the trace-route
test will take place. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.8 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8
·
1 row entry
·
7 columns
This table contains results of traceroute test.
An entry contains the objects for the traceroute test.
Indexes
applTracerouteResultTestId applTracerouteHopCount
| Column | Syntax | OID |
|---|---|---|
|
applTracerouteResultTestId
mandatory
A unique ID to identify each application test.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.1 |
|
applTracerouteHopCount
mandatory
This object contains the number of hops to reach the gateway.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.2 |
|
applTracerouteIpAddr
mandatory
This object contains the IP address of the gateway.
|
RFC1155-SMIIpAddress Textual Convention: RFC1155-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.3 |
|
applTraceroutePktSize
mandatory
This object corresponds to the size of the packet (in bytes)
which will be sent during the traceroute test. Please refer to product specific documentation for the default values supported |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.4 |
|
applTracerouteProbe1RTT
mandatory
This object contains the round trip time (rtt) of the first
probe sent to the gateway. If the probe has a timeout the rtt is set to -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.5 |
|
applTracerouteProbe2RTT
mandatory
This object contains the round trip time (rtt) of the second
probe sent to the gateway. If the probe has a timeout the rtt is set to -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.6 |
|
applTracerouteProbe3RTT
mandatory
This object contains the round trip time (rtt) of the third
probe sent to the gateway. If the probe has a timeout the rtt is set to -1. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.7 |