PBI-MGSIGNALCHARACTERISTICS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
8
Rows
8
Columns
29
.1.3.6.1.4.1.1070.3.2.1 · 1 row entry · 8 columns
tsOutEntry entry .1.3.6.1.4.1.1070.3.2.1.1
Row Description
Indexes
channelOutput
Column Syntax OID
channelOutput
output channel number
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.1
bitRate
Transport stream output size, 3000EC: from 0 to 16Mpbs; 3000MX:from 0 to 100Mpbs; 3000TM: from 0 to 50Mpbs
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.2
packetSize
Packet length, option: 188 or 204
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.3
transportStreamID
The transport stream ID for this transport stream as read from the PAT, its value range: reference ISO/IEC 13818-1
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.4
otiginalNetworkID
The original network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.5
networkID
The network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.6
bitrateThreshosdPercent
ts overflow percent value(0 - 100)
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.7
outValidBitRate
transport stream out valid bit rate
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.1.1.8
.1.3.6.1.4.1.1070.3.2.2 · 1 row entry · 2 columns
PSI/SI information relating to the PAT, reference ISO/IEC 13818-1
mgPATEntry entry .1.3.6.1.4.1.1070.3.2.2.1
Row Description
Indexes
channelInputPAT
Column Syntax OID
channelInputPAT
The physical input on which this transport stream appears
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.1070.3.2.2.1.1
patSection
The transport stream Relating to the PAT seciton, reference ISO/IEC 13818-1
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.2.1.2
.1.3.6.1.4.1.1070.3.2.3 · 1 row entry · 4 columns
PSI/SI information relating to the PMT
mgPMTEntry entry .1.3.6.1.4.1.1070.3.2.3.1
Row Description
Indexes
channelInputPMT
Column Syntax OID
channelInputPMT
The physical input on which this transport stream appears
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.3.1.1
pmtProgramNumber
The PMT program number as read from PMT,reference ISO/IEC 13818-1
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.3.1.2
pmtPID
The PMT PID as read from PMT,reference ISO/IEC 13818-1
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.3.1.3
pmtSection
The transport stream Relating to the PMT seciton, reference ISO/IEC 13818-1
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.3.1.4
.1.3.6.1.4.1.1070.3.2.4 · 1 row entry · 4 columns
PSI/SI information relating to the NIT
mgNITEntry entry .1.3.6.1.4.1.1070.3.2.4.1
Row Description
Indexes
channelInputNIT
Column Syntax OID
channelInputNIT
The physical input on which this transport stream appears
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.4.1.1
networkType
The network type include two types: actual NIT and others NIT, reference DVB 300-468
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.4.1.2
nitActualSection
Relating to the Actual section, its table ID is 0x40 in NIT,reference DVB 300-468
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.4.1.3
nitOhtersSection
Relating to the others section , its table ID is 0x41 in NIT,reference DVB 300-468
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.4.1.4
.1.3.6.1.4.1.1070.3.2.5 · 1 row entry · 2 columns
PSI/SI information relating to the SDT, reference DVB 300-468
mgSDTEntry entry .1.3.6.1.4.1.1070.3.2.5.1
Row Description
Indexes
channelInputSDT
Column Syntax OID
channelInputSDT
The physical input on which this transport stream appears
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.5.1.1
sdtSection
The transport stream relating to SDT seciton, reference DVB 300-468
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.5.1.2
.1.3.6.1.4.1.1070.3.2.6 · 1 row entry · 5 columns
Description
mgFilterEntry entry .1.3.6.1.4.1.1070.3.2.6.1
Row Description
Indexes
channelInputFilter
Column Syntax OID
channelInputFilter
The physical input on which this transport stream appears
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.6.1.1
oldPID
The old PID will be filtered output
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.6.1.2
newPID
The new PID is bulit according to old PID
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.6.1.3
oldProgramNumber
The old program number,they come from PAT and will be filtered output
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.6.1.4
newProgramNumber
The new program number, they are bulit and will be made a new PAT
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.6.1.5
.1.3.6.1.4.1.1070.3.2.7 · 1 row entry · 2 columns
PSI/SI information relating to the CAT, reference ISO/IEC 13818-1
mgCATEntry entry .1.3.6.1.4.1.1070.3.2.7.1
Row Description
Indexes
channelInputCAT
Column Syntax OID
channelInputCAT
The physical input on which this transport stream appears
Integer32r/w
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.1070.3.2.7.1.1
catSection
The transport stream Relating to the CAT seciton, reference ISO/IEC 13818-1
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.7.1.2
.1.3.6.1.4.1.1070.3.2.9 · 1 row entry · 2 columns
PSI/SI information relating to the BAT, reference ISO/IEC 13818-1
mgBATEntry entry .1.3.6.1.4.1.1070.3.2.9.1
Row Description
Indexes
channelBAT
Column Syntax OID
channelBAT
specify channel of get BAT
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.1070.3.2.9.1.1
batSection
The transport stream Relating to the BAT seciton, reference ISO/IEC 13818-1
OctetStringr/w
Constraints:
range: 0-1024
.1.3.6.1.4.1.1070.3.2.9.1.2