.1.3.6.1.4.1.111.7.1.1
·
1 row entry
·
2 columns
The table of information about a Multiprotocol Interchange.
An entry in the table associated with a Multiprotocol Interchange.
Indexes
NETWORK-SERVICES-MIBapplIndex
| Column | Syntax | OID |
|---|---|---|
|
oraInterchgConfigDirectory
mandatory
The directory which contains the Multiprotocol Interchange
configuration files. The default TNS_ADMIN directory is /$ORACLE_HOME/NETWORK/ADMIN. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.1.1.1 |
|
oraInterchgContactInfo
mandatory
Provides the information of the person to contact for the
Multiprotocol Interchange issue, this information is read from the SNMP.ORA file. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.1.1.2 |
.1.3.6.1.4.1.111.7.1.6
·
1 row entry
·
23 columns
The table of information about the status of a Connection Manager.
An entry in the table associated with a Connection Manager.
Indexes
NETWORK-SERVICES-MIBapplIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
oraCmanagerStartTime
mandatory
The time when a Connection Manager was started. The format is
date-month-yr hr:min:sec. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.6.1.1 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerRunningTime
mandatory
The elapsed time in secs since a Connection Manager
was last started. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.6.1.2 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerLogging
mandatory
Indicates whether a Connection Manager should log the requests.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.111.7.1.6.1.3 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerLogFile
mandatory
Indicates the name of the log file the Connection Manager created.
The default log file name is /$ORACLE_HOME/network/log/intlsnr.log, where $ORACLE_HOME is the path which the ORACLE_HOME points to. |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.6.1.4 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerTraceLevel
mandatory
Indicates the level at which a Connection Manager should be traced.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.111.7.1.6.1.5 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerTraceFile
mandatory
Indicates the name of the trace file the Connection Manager created.
On an Unix platform, the default trace file name is /$ORACLE_HOME/network/trace/cmg_pid.trc, where pid is the process ID of the Connection Manager an… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.6.1.6 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerStoppable
mandatory
Indicates whether a Connection Manager can be stopped
by the Multiprotocol Interchange Control Utility program. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.111.7.1.6.1.7 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerMaximumPumps
mandatory
The maximum number of pumps that can be started by the Connection
Manager. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.8 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerMaximumConnectionsPerPump
mandatory
The maximum number of connections per pump that can be started by
the Connection Manager. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.9 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerPumpStrategy
mandatory
Indicates a Pump allocation strategy.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.111.7.1.6.1.10 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerActivePumps
mandatory
The total number of pumps that are currently active.
|
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.6.1.11 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerMaximumConnections
mandatory
The maximum number of connections that are available.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.12 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerCurrentConnectionsInUse
mandatory
The total number of connections that are currently used.
|
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.6.1.13 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerAccumulatedSuccessfulConnections
mandatory
The total number of successful connections through the
Multiprotocol Interchange. |
RFC1155-SMICounter Textual Convention: RFC1155-SMICounter Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.6.1.14 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerAccumulatedFailedConnections
mandatory
The total number of unsuccessful connections through the
Multiprotocol Interchange. |
RFC1155-SMICounter Textual Convention: RFC1155-SMICounter Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.6.1.15 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerImmediateAverageBytes
mandatory
The immediate average number of bytes sent per second.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.16 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerMaximumConnectTime
mandatory
The maximum time in centi-seconds to establish a connection.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.17 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerMinimumConnectTime
mandatory
The minimum time in centi-seconds to establish a connection.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.18 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerAverageConnectTime
mandatory
The average time in centi-seconds to establish a connection.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.19 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerMaximumConnectDuration
mandatory
The maximum connection duration time in centi-seconds. This is the
elapsed time between a connection is established and before the connection is terminated. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.6.1.20 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerState
mandatory
Indicates the current state of a Connection Manager.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.111.7.1.6.1.21 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerErrors
mandatory
The error stack of a Connection Manager when it fails.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.6.1.22 |
||||||||||||||||||||||||||||||||||
|
oraCmanagerErrorMessage
mandatory
The error message of a Connection Manager when it fails.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.6.1.23 |
.1.3.6.1.4.1.111.7.1.7
·
1 row entry
·
2 columns
The table of information about the addresses that a Connection Manager is listening on.
An entry in the table associated with the addresses at which
a Connection Manager is listening on.
a Connection Manager is listening on.
Indexes
NETWORK-SERVICES-MIBapplIndex oraCmanagerListenAddressIndex
| Column | Syntax | OID |
|---|---|---|
|
oraCmanagerListenAddressIndex
mandatory
A numeric index, unique among all the listen addresses
at which a Connection Manager is listening on. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.7.1.1 |
|
oraCmanagerListenAddress
mandatory
The address at which a Connection Manager is listening on.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.7.1.2 |
.1.3.6.1.4.1.111.7.1.8
·
1 row entry
·
2 columns
The table of information about the addresses that a Connection Manager fails to listen on.
An entry in the table associated with the addresses
that a Connection Manager fails to listen on.
that a Connection Manager fails to listen on.
Indexes
NETWORK-SERVICES-MIBapplIndex oraCmanagerFailedAddressIndex
| Column | Syntax | OID |
|---|---|---|
|
oraCmanagerFailedAddressIndex
mandatory
A numeric index, unique among all the addresses which
a Connection Manager fails to listen on. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.8.1.1 |
|
oraCmanagerFailedAddress
mandatory
The address that a Connection Manager fails to listen on.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.8.1.2 |
.1.3.6.1.4.1.111.7.1.9
·
1 row entry
·
19 columns
The table of information about the status of a Pump.
An entry in the table associated with a Pump.
Indexes
NETWORK-SERVICES-MIBapplIndex oraPumpIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
oraPumpIndex
mandatory
A numeric index, unique among all the pumps.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.1 |
||||||||||||||||||||||||||||||||||
|
oraPumpActiveTime
mandatory
The number of minutes a Pump remains active after the last
connection disconnects. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.2 |
||||||||||||||||||||||||||||||||||
|
oraPumpTraceLevel
mandatory
Indicates the level at which a Pump should be traced.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.111.7.1.9.1.3 |
||||||||||||||||||||||||||||||||||
|
oraPumpTraceFile
mandatory
Indicates the name of the trace file the pump created.
On an Unix platform, the default trace file name is /$ORACLE_HOME/network/trace/pmp_PID.trc, where pid is the process ID of the pump and $ORACLE_HOME is the path wh… |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.9.1.4 |
||||||||||||||||||||||||||||||||||
|
oraPumpActiveConnections
mandatory
The number of connections that are currently active.
|
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.9.1.5 |
||||||||||||||||||||||||||||||||||
|
oraPumpSuccessfulConnections
mandatory
The total number of successful connections through the pump.
|
RFC1155-SMICounter Textual Convention: RFC1155-SMICounter Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.9.1.6 |
||||||||||||||||||||||||||||||||||
|
oraPumpFailedConnections
mandatory
The total number of unsuccessful connections through the pump.
|
RFC1155-SMICounter Textual Convention: RFC1155-SMICounter Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.9.1.7 |
||||||||||||||||||||||||||||||||||
|
oraPumpAccumulatedBytesSent
mandatory
The total number of bytes sent through the pump.
|
RFC1155-SMICounter Textual Convention: RFC1155-SMICounter Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.9.1.8 |
||||||||||||||||||||||||||||||||||
|
oraPumpCurrentBytesPerSecond
mandatory
The current number of bytes sent per second through the pump.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.9 |
||||||||||||||||||||||||||||||||||
|
oraPumpMaximumAverageBytes
mandatory
The maximum average number of bytes sent through the pump.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.10 |
||||||||||||||||||||||||||||||||||
|
oraPumpImmediateAverageBytes
mandatory
The immediate average number of bytes sent through the pump.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.11 |
||||||||||||||||||||||||||||||||||
|
oraPumpMaximumConnectTime
mandatory
The maximum time in centi-seconds to establish a connection.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.12 |
||||||||||||||||||||||||||||||||||
|
oraPumpMinimumConnectTime
mandatory
The minimum time in centi-seconds to establish a connection.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.13 |
||||||||||||||||||||||||||||||||||
|
oraPumpAverageConnectTime
mandatory
The average time in centi-seconds to establish a connection.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.14 |
||||||||||||||||||||||||||||||||||
|
oraPumpMaximumConnectDuration
mandatory
The maximum connection duration time in centi-seconds. This is the
elapsed time between a connection is established and before the connection is terminated. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.15 |
||||||||||||||||||||||||||||||||||
|
oraPumpMaximumBuffers
mandatory
The maximum number of buffers available for use by connections
in the pump. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.9.1.16 |
||||||||||||||||||||||||||||||||||
|
oraPumpBufferUtilization
mandatory
The pump buffer utilization in percentage.
|
RFC1155-SMIGauge Textual Convention: RFC1155-SMIGauge Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.111.7.1.9.1.17 |
||||||||||||||||||||||||||||||||||
|
oraPumpErrors
mandatory
The error stack of a Pump when it fails.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.9.1.18 |
||||||||||||||||||||||||||||||||||
|
oraPumpErrorMessage
mandatory
The error message of a Pump when it fails.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.9.1.19 |
.1.3.6.1.4.1.111.7.1.10
·
1 row entry
·
2 columns
The table of information about the addresses that a Pump is listening on.
An entry in the table associated with the addresses at which
a Pump is listening on.
a Pump is listening on.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
oraPumpListenAddressIndex
mandatory
A numeric index, unique among all the listen addresses at which
a pump is listening on. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.10.1.1 |
|
oraPumpListenAddress
mandatory
The address at which a Pump is listening on.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.10.1.2 |
.1.3.6.1.4.1.111.7.1.11
·
1 row entry
·
2 columns
The table of information about the addresses that a Pump fails to listen on.
An entry in the table associated with the addresses
that a Pump fails to listen on.
that a Pump fails to listen on.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
oraPumpFailedAddressIndex
mandatory
A numeric index, unique among all the addresses which
a pump fails to listen on. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.11.1.1 |
|
oraPumpFailedAddress
mandatory
The address that a Pump fails to listen on.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.11.1.2 |
.1.3.6.1.4.1.111.7.1.12
·
1 row entry
·
6 columns
The table of information about the status of a connection.
An entry in the table associated with a connection.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
oraConnectionIndex
mandatory
A numeric index, unique among all the connections that a pump has.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.12.1.1 |
|
oraConnectionPumpID
mandatory
The Pump ID of a connection.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.12.1.2 |
|
oraConnectionIdleTime
mandatory
The number of minutes a connection can remain idle before
a Connection Manager will terminate it. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.12.1.3 |
|
oraConnectionDuration
mandatory
The elapsed time is centi-seconds after a connection was established
and before a connection is terminated. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.111.7.1.12.1.4 |
|
oraConnectionSourceAddress
mandatory
The source address of a connect request.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.12.1.5 |
|
oraConnectionDestinationAddress
mandatory
The destination address of a connect request.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.111.7.1.12.1.6 |