OMNITRON-IP-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
17
.1.3.6.1.4.1.7342.21.2 · 1 row entry · 6 columns
This table supports IPv6 configuration. Rows in this table are
automatically created, one for each possible configurable IPv6 address
on an interface.
          
The first entry for an interface is always reserved for the Link Local
type and is automatically created by the SNMP Agent.
          
Only one IPv6 of each type is allowed per interface.
ostIpCfgEntry entry .1.3.6.1.4.1.7342.21.2.1
This is a IP configuration table entry.
Indexes
ostIpCfgIndex
Column Syntax OID
ostIpCfgIndex
An index that is used to identify the specific interface that the IP
is configured on.
OMNITRON-TC-MIBOstPortNumber
Textual Convention: OMNITRON-TC-MIBOstPortNumber Unsigned32
Type Constraints:
range: 0..99
.1.3.6.1.4.1.7342.21.2.1.1
ostIpCfgInterfaceType
This object indicates the specific interface type of IPv6 address.

stateless(1) Stateless (automatic) IPv6 interface type
statefull(2) Stateful (manual) IPv6 interface type
Enumerationr/w
Enumerated Values:
1stateless
2stateful
.1.3.6.1.4.1.7342.21.2.1.2
ostIpCfgStatefulAddress
This object indicates the IPv6 stateful address for an interface.
OMNITRON-TC-MIBOstIpAddrr/w
Textual Convention: OMNITRON-TC-MIBOstIpAddr OctetString
Type Constraints:
range: 0..39
.1.3.6.1.4.1.7342.21.2.1.3
ostIpCfgStatefulPrefixLength
This object configures the IPv6 stateful address prefix length.
Unsigned32r/w
Constraints:
range: 1-128
.1.3.6.1.4.1.7342.21.2.1.4
ostIpCfgGatewayAddress
This object indicates the IPv6 gateway address.
OMNITRON-TC-MIBOstIpAddrr/w
Textual Convention: OMNITRON-TC-MIBOstIpAddr OctetString
Type Constraints:
range: 0..39
.1.3.6.1.4.1.7342.21.2.1.5
ostIpCfgLinkLocalAddress
This object indicates the link local IPv6 address for an interface. The
default value is the based upon the MAC address of the interface:
'fe80::<MAC address>'
OMNITRON-TC-MIBOstIpAddrr/w
Textual Convention: OMNITRON-TC-MIBOstIpAddr OctetString
Type Constraints:
range: 0..39
.1.3.6.1.4.1.7342.21.2.1.6
.1.3.6.1.4.1.7342.21.3 · 1 row entry · 7 columns
This table supports IPv6 status. Rows in this table are
automatically created, one for each possible configurable IPv6 address
on an interface.
          
The first entry for an interface is always reserved for the Link Local
type and is automatically created by the SNMP Agent.
          
Only one IPv6 of each type is allowed per interface.
ostIpStatusEntry entry .1.3.6.1.4.1.7342.21.3.1
This is a IP status table entry.
Indexes
ostIpStatusIndex ostIpStatusInstance
Column Syntax OID
ostIpStatusIndex
An index that is used to identify the specific interface that the IP
is configured on.
OMNITRON-TC-MIBOstPortNumber
Textual Convention: OMNITRON-TC-MIBOstPortNumber Unsigned32
Type Constraints:
range: 0..99
.1.3.6.1.4.1.7342.21.3.1.1
ostIpStatusInstance
This object specifies specific instance of IPv6 address on an
interface. Instance 1 is reserved for linkLocal type.
Unsigned32
Constraints:
range: 1-4
.1.3.6.1.4.1.7342.21.3.1.2
ostIpStatusAddressType
This object indicates the address type of the IPv6 address.

linkLocal(0) Link Local address (static) IPv6 address type
stateless(1) Stateless (automatic) IPv6 address type
statefull(2) Stateful (man…
Enumeration
Enumerated Values:
0linkLocal
1stateless
2stateful
.1.3.6.1.4.1.7342.21.3.1.3
ostIpStatusStatus
This object indicates the status of the IPv6 host (interface)

notApplicable(1) IPv6 address is not available or not enabled for
this entry
addressValid(2) IPv6 address (stateful or L…
Enumeration
Enumerated Values:
1notApplicable
2addressValid
3autoInProcess
4autoSuccessful
.1.3.6.1.4.1.7342.21.3.1.4
ostIpStatusAddress
This object indicates the IPv6 address for an interface.
OMNITRON-TC-MIBOstIpAddr
Textual Convention: OMNITRON-TC-MIBOstIpAddr OctetString
Type Constraints:
range: 0..39
.1.3.6.1.4.1.7342.21.3.1.5
ostIpStatusPrefixLength
This object indicates the IPv6 address prefix length.
Unsigned32
Constraints:
range: 1-128
.1.3.6.1.4.1.7342.21.3.1.6
ostIpStatusGatewayAddress
This object indicates the IPv6 gateway address. The default
value is the Link Local address.
OMNITRON-TC-MIBOstIpAddr
Textual Convention: OMNITRON-TC-MIBOstIpAddr OctetString
Type Constraints:
range: 0..39
.1.3.6.1.4.1.7342.21.3.1.7
.1.3.6.1.4.1.7342.21.4 · 1 row entry · 4 columns
This table supports the IPv6 Traphost configurations. Rows in this
table are automatically created, one for each possible configurable
traphost.
ostIpTraphostCfgEntry entry .1.3.6.1.4.1.7342.21.4.1
This is a IP traphost configuration table entry.
Indexes
ostIpTraphostCfgIndex
Column Syntax OID
ostIpTraphostCfgIndex
An index that is used to identify a specific IP traphost.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.7342.21.4.1.1
ostIpTraphostCfgIpAddress
IPv4 or IPv6 Notification destination address.

A value of 0 indicates no trap host address is configured
via this object.

Setting this object also impacts the traphostx
returned value. If a…
OMNITRON-TC-MIBOstIpAddrr/w
Textual Convention: OMNITRON-TC-MIBOstIpAddr OctetString
Type Constraints:
range: 0..39
.1.3.6.1.4.1.7342.21.4.1.2
ostIpTraphostCfgIpSource
This object configures the SNMP notification source IP address. It is
used to configure an SNMP notification that is generated by the
indicated traphost.

global (0) No specific traphost value, the global…
Enumerationr/w
Enumerated Values:
0global
1ip1
2ip2
.1.3.6.1.4.1.7342.21.4.1.3
ostIpTraphostCfgUdpPort
This object configures the SNMP notification UDP port number for the
indicated traphost when an SNMP notification is generated from the
traphost.

A value of '0' indicates the global object ostSnmpTrapPort…
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.7342.21.4.1.4