OCP-ONL-SENSOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
24
.0.2.1 · 1 row entry · 4 columns
Table of temperature sensors and their values.
onlTempSensorsEntry entry .0.2.1.1
An entry containing a device and its statistics.
Indexes
onlTempSensorsIndex
Column Syntax OID
onlTempSensorsIndex
Reference index for each observed device.
Integer32
Constraints:
range: 0-65535
.0.2.1.1.1
onlTempSensorsDevice
The name of the temperature sensor we are reading.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.1.1.2
onlTempSensorsStatus
The status of this sensor.
0: missing
1: good
2: failed.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.2.1.1.3
onlTempSensorsValue
The temperature of this sensor in mC.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.1.1.4
.0.2.2 · 1 row entry · 8 columns
Table of fan sensors and their values.
onlFanSensorsEntry entry .0.2.2.1
An entry containing a device and its statistics.
Indexes
onlFanSensorsIndex
Column Syntax OID
onlFanSensorsIndex
Reference index for each observed device.
Integer32
Constraints:
range: 0-65535
.0.2.2.1.1
onlFanSensorsDevice
The name of the fan sensor we are reading.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.2.1.2
onlFanSensorsStatus
Status of the fan.
0: missing
1: good
2: failed.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.2.2.1.3
onlFanSensorsFlowType
Flow type of the fan.
unknown: unknown type
f2b: front to back
b2f: back to front.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.2.1.4
onlFanSensorsRPM
The rotation speed of the fan in RPM.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.2.1.5
onlFanSensorsPct
The percentage of the fan.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.2.1.6
onlFanSensorsModel
The model of the fan sensor we are reading.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.2.1.7
onlFanSensorsSerial
The serial number of the fan sensor we are reading.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.2.1.8
.0.2.3 · 1 row entry · 12 columns
Table of power suply unit sensors and their values.
onlPSUSensorsEntry entry .0.2.3.1
An entry containing a device and its statistics.
Indexes
onlPSUSensorsIndex
Column Syntax OID
onlPSUSensorsIndex
Reference index for each observed device.
Integer32
Constraints:
range: 0-65535
.0.2.3.1.1
onlPSUSensorsDevice
The name of the device we are reading.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.3.1.2
onlPSUSensorsStatus
The status of the PSU.
0: missing
1: good
2: failed.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.0.2.3.1.3
onlPSUSensorsCurrentType
The current type of the PSU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.3.1.4
onlPSUSensorsModel
The model of the PSU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.3.1.5
onlPSUSensorsVin
The input voltage in mV.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.3.1.6
onlPSUSensorsVout
The output voltage in mV.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.3.1.7
onlPSUSensorsIin
The input current in mA.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.3.1.8
onlPSUSensorsIout
The output current in mA.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.3.1.9
onlPSUSensorsPin
The input power in mW.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.3.1.10
onlPSUSensorsPout
The output power in mW.
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.0.2.3.1.11
onlPSUSensorsSerial
The serial number of the PSU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.0.2.3.1.12