ME1200-SYSUTIL-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
4
Rows
4
Columns
11
.1.3.6.1.4.1.9.9.815.1.24.1.3.2
·
1 row entry
·
5 columns
Table of power supply status.
Each row contains the power supply status.
Indexes
me1200SysutilStatusPowerSupplySwitchId me1200SysutilStatusPowerSupplyPsuId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
me1200SysutilStatusPowerSupplySwitchId
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.1 |
||||||
|
me1200SysutilStatusPowerSupplyPsuId
The identification of power supply.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.2 |
||||||
|
me1200SysutilStatusPowerSupplyState
The state of power supply.
|
ME1200SysutilPowerSupplyStateType Textual Convention: ME1200SysutilPowerSupplyStateType EnumerationType Values:
|
.1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.3 |
||||||
|
me1200SysutilStatusPowerSupplyDescription
The description of power supply.
|
OctetString Constraints: range: 0-30 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.4 |
||||||
|
me1200SysutilVoltageStatus
Status of differnt system voltages.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.5 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.3
·
1 row entry
·
2 columns
Table of system LED status.
Each row contains the system LED status.
Indexes
me1200SysutilStatusSystemLedSwitchId
| Column | Syntax | OID |
|---|---|---|
|
me1200SysutilStatusSystemLedSwitchId
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.3.1.1 |
|
me1200SysutilStatusSystemLedDescription
The description of system LED status.
|
OctetString Constraints: range: 0-127 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.3.1.2 |
.1.3.6.1.4.1.9.9.815.1.24.1.4.1
·
1 row entry
·
2 columns
This is a table to reboot a swicth
Each switch has a set of parameters
Indexes
me1200SysutilControlRebootSwitchId
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
me1200SysutilControlRebootSwitchId
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.815.1.24.1.4.1.1.1 |
||||||
|
me1200SysutilControlRebootType
Type of reboot. noReboot(0) does not reboot. coldReboot(1) is to do
cold reboot. warmReboot(2) is to do warm reboot, but this is optional. The OID of vtssSysutilCapabilitiesWarmRebootSupported tells if warm reboot is su… |
ME1200SysutilRebootTyper/w Textual Convention: ME1200SysutilRebootType EnumerationType Values:
|
.1.3.6.1.4.1.9.9.815.1.24.1.4.1.1.2 |
.1.3.6.1.4.1.9.9.815.1.24.1.4.2
·
1 row entry
·
2 columns
This is a table to clear the system LED error status
Each switch has a set of parameters
Indexes
me1200SysutilControlSystemLedSwitchId
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
me1200SysutilControlSystemLedSwitchId
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.815.1.24.1.4.2.1.1 |
||||||||||||
|
me1200SysutilControlSystemLedClearStatus
Type of system LED status clearing.all(0) is used to clear all error
status of the system LED and back to normal indication. fatal(1) is used to clear fatal error status of the system LED. software(2) is used to clear g… |
ME1200SysutilSystemLedClearTyper/w Textual Convention: ME1200SysutilSystemLedClearType EnumerationType Values:
|
.1.3.6.1.4.1.9.9.815.1.24.1.4.2.1.2 |