JUNIPER-RPM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
32
.1.3.6.1.4.1.2636.3.50.1.1 · 1 row entry · 4 columns
This table provides measurements from the latest individual RPM 
probe samples.  Within each sample, the specific measurement type 
is identified by jnxRpmResSampleType.  Note, if the latest
probe was unsuccessful, no measurement types will be available.
          
See the definition of JnxRpmMeasurementType for details on
the types of measurements available.
jnxRpmResultsSampleEntry entry .1.3.6.1.4.1.2636.3.50.1.1.1
Each entry provides a specific measurement type for a single
probe.
Indexes
DISMAN-PING-MIBpingCtlOwnerIndex DISMAN-PING-MIBpingCtlTestName jnxRpmResSampleType
Column Syntax OID
jnxRpmResSampleType
This object identifies the specific measurement type returned
by jnxRpmResSampleValue.
JnxRpmMeasurementType
Textual Convention: JnxRpmMeasurementType Enumeration
Type Values:
1roundTripTime
2rttJitter
3rttInterarrivalJitter
4egress
5egressJitter
6egressInterarrivalJitter
7ingress
8ingressJitter
9ingressInterarrivalJitter
.1.3.6.1.4.1.2636.3.50.1.1.1.1
jnxRpmResSampleValue
This object returns the measurement identified by the corresponding
jnxRpmResSampleType.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.50.1.1.1.2
jnxRpmResSampleTsType
This object identifies the type of timestamp used to obtain this
measurement.
JnxRpmTimestampType
Textual Convention: JnxRpmTimestampType Enumeration
Type Values:
1software
2clientHardware
3clientAndServerHardware
.1.3.6.1.4.1.2636.3.50.1.1.1.3
jnxRpmResSampleDate
This object provides the date and time of when this measurement
was obtained.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.2636.3.50.1.1.1.4
.1.3.6.1.4.1.2636.3.50.1.2 · 1 row entry · 5 columns
This table provides a summary of the results for a specific
RPM entry (identified by pingCtlOwnerIndex/pingCtlTestName).
The scope of the summary is identified by jnxRpmResSumCollection.
jnxRpmResultsSummaryEntry entry .1.3.6.1.4.1.2636.3.50.1.2.1
Each entry in the table provides a summary of the RPM results
over a single collection of probes. For each RPM entry, there
are several collections maintained: the current test, the
most recently completed test, a conf…
Indexes
DISMAN-PING-MIBpingCtlOwnerIndex DISMAN-PING-MIBpingCtlTestName jnxRpmResSumCollection
Column Syntax OID
jnxRpmResSumCollection
This object identifes the collection of probes over which the
summary data represented by the other objects in this table
applies. Note, if a collection type is not supported or not
configured, it will not be instanti…
JnxRpmCollectionType
Textual Convention: JnxRpmCollectionType Enumeration
Type Values:
1currentTest
2lastCompletedTest
3movingAverage
4allTests
.1.3.6.1.4.1.2636.3.50.1.2.1.1
jnxRpmResSumSent
This object provides the number of probes sent within the
collection identified by jnxRpmResSumCollection.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.2.1.2
jnxRpmResSumReceived
This object provides the number of probes received within the
collection identified by jnxRpmResSumCollection.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.2.1.3
jnxRpmResSumPercentLost
This object provides the percentage of probes lost within the
collection identified by jnxRpmResSumCollection.
JnxRpmPercentType
Textual Convention: JnxRpmPercentType Unsigned32
Type Constraints:
range: 0..100000000
.1.3.6.1.4.1.2636.3.50.1.2.1.4
jnxRpmResSumDate
This object provides the date and time of when the most recent
probe within the collection identified by jnxRpmResSumCollection
was completed.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.2636.3.50.1.2.1.5
.1.3.6.1.4.1.2636.3.50.1.3 · 1 row entry · 8 columns
This table provides a set of calculated values for each
RPM entry, for each collection of probes maintained within that
entry, and for each supported measurement set within that 
collection of probes.
          
Note, not all collection types will be available for every
RPM Entry (identified by pingCtlOwnerIndex/pingCtlTestName).
The jitter calculations are available only for those RPM entries 
that employ hardware timestamps.  Further, the ingress & egress
calculations are available only for those probe types that
measure one-way delays or where hardware timestamps are 
employed and the one-way-hardware timestamp knob is enabled.  
In either case, the one-way delays must be less than the round
trip times, otherwise they are discarded.
          
Also, this table will skip over any measurement set for which
there are 0 samples.
jnxRpmResultsCalculatedEntry entry .1.3.6.1.4.1.2636.3.50.1.3.1
Indexes
DISMAN-PING-MIBpingCtlOwnerIndex DISMAN-PING-MIBpingCtlTestName jnxRpmResSumCollection jnxRpmResCalcSet
Column Syntax OID
jnxRpmResCalcSet
This object identifies the measurement set upon which the
calculations returned by the other objects in this table are
based.
JnxRpmMeasurementSet
Textual Convention: JnxRpmMeasurementSet Enumeration
Type Values:
1roundTripTime
2posRttJitter
3negRttJitter
4egress
5posEgressJitter
6negEgressJitter
7ingress
8posIngressJitter
9negIngressJitter
.1.3.6.1.4.1.2636.3.50.1.3.1.1
jnxRpmResCalcSamples
The number of samples used in this calculations.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.3.1.2
jnxRpmResCalcMin
The minimum of all the samples in the collection and measurement
set associated with this row. Values are provided in units
of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.3.1.3
jnxRpmResCalcMax
The maximum of all the samples in the collection and measurement
set associated with this row. Values are provided in units
of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.3.1.4
jnxRpmResCalcAverage
The average of all the samples in the collection and measurement
set associated with this row. Values are provided in units
of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.3.1.5
jnxRpmResCalcPkToPk
The difference between the minimum and maximum of all the samples
in the collection and measurement set associated with this row.
Values are provided in units of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.3.1.6
jnxRpmResCalcStdDev
The standard deviation calculated over all the samples
in the collection and measurement set associated with this row.
Values are provided in units of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.3.1.7
jnxRpmResCalcSum
The sum of all the samples in the collection and measurement set
associated with this row. Values are provided in units of
microseconds.
HCNUM-TCCounterBasedGauge64
Textual Convention: HCNUM-TCCounterBasedGauge64 Unsigned64
.1.3.6.1.4.1.2636.3.50.1.3.1.8
.1.3.6.1.4.1.2636.3.50.1.4 · 1 row entry · 3 columns
This table provides measurements for individual RPM probe samples.
In addition to the last completed sample, a configurable number of
the most recent samples are available as well.  Within each sample,
the specific measurement type is identified by
jnxRpmHistSampleType.  Note, if probe was unsuccessful, no 
measurement types will be available for that history entry.
          
See the definition of JnxRpmMeasurementType for details on
the types of measurements available.
jnxRpmHistorySampleEntry entry .1.3.6.1.4.1.2636.3.50.1.4.1
Indexes
DISMAN-PING-MIBpingCtlOwnerIndex DISMAN-PING-MIBpingCtlTestName DISMAN-PING-MIBpingProbeHistoryIndex jnxRpmHistSampleType
Column Syntax OID
jnxRpmHistSampleType
This object identifies the specific measurement type returned
by jnxRpmHistSampleValue.
JnxRpmMeasurementType
Textual Convention: JnxRpmMeasurementType Enumeration
Type Values:
1roundTripTime
2rttJitter
3rttInterarrivalJitter
4egress
5egressJitter
6egressInterarrivalJitter
7ingress
8ingressJitter
9ingressInterarrivalJitter
.1.3.6.1.4.1.2636.3.50.1.4.1.1
jnxRpmHistSampleValue
This object returns the measurement identified by the corresponding
jnxRpmHistSampleType.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2636.3.50.1.4.1.2
jnxRpmHistSampleTsType
This object identifies the type of timestamp used to obtain this
measurement.
JnxRpmTimestampType
Textual Convention: JnxRpmTimestampType Enumeration
Type Values:
1software
2clientHardware
3clientAndServerHardware
.1.3.6.1.4.1.2636.3.50.1.4.1.3
.1.3.6.1.4.1.2636.3.50.1.5 · 1 row entry · 4 columns
This table provides historical summary data for each collection
of probes within each RPM Entry, similar to the
jnxRpmResultsSummaryTable.  
          
In addition to the current summary, this table provides the same 
number of historical entries as the jnxRpmHistorySampleTable.
jnxRpmHistorySummaryEntry entry .1.3.6.1.4.1.2636.3.50.1.5.1
Indexes
DISMAN-PING-MIBpingCtlOwnerIndex DISMAN-PING-MIBpingCtlTestName DISMAN-PING-MIBpingProbeHistoryIndex jnxRpmHistSumCollection
Column Syntax OID
jnxRpmHistSumCollection
Identifies the collection of probes whose results are summarized by
this row.

At this time, historical summaries are available only for the
current test (currentTest(1)).
JnxRpmCollectionType
Textual Convention: JnxRpmCollectionType Enumeration
Type Values:
1currentTest
2lastCompletedTest
3movingAverage
4allTests
.1.3.6.1.4.1.2636.3.50.1.5.1.1
jnxRpmHistSumSent
This object provides the number of probes sent within the
collection identified by jnxRpmHistSumCollection.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.5.1.2
jnxRpmHistSumReceived
This object provides the number of probes received within the
collection identified by jnxRpmHistSumCollection.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.5.1.3
jnxRpmHistSumPercentLost
This object provides the percentage of probes lost within the
collection identified by jnxRpmHistSumCollection.
JnxRpmPercentType
Textual Convention: JnxRpmPercentType Unsigned32
Type Constraints:
range: 0..100000000
.1.3.6.1.4.1.2636.3.50.1.5.1.4
.1.3.6.1.4.1.2636.3.50.1.6 · 1 row entry · 8 columns
This table provides a set of calculated values for each
RPM entry, for each collection of probes maintained within that
entry, and for each supported calculated type within that 
collection of probes, similar to the jnxRpmResultsCalculatedTable.
          
In addition to the current summary, this table provides the same 
number of historical entries as the jnxRpmHistorySampleTable.
jnxRpmHistoryCalculatedEntry entry .1.3.6.1.4.1.2636.3.50.1.6.1
Indexes
DISMAN-PING-MIBpingCtlOwnerIndex DISMAN-PING-MIBpingCtlTestName DISMAN-PING-MIBpingProbeHistoryIndex jnxRpmHistSumCollection jnxRpmHistCalcSet
Column Syntax OID
jnxRpmHistCalcSet
This object identifies the measurement set upon which the
calculations returned by the other objects in this table are
based.
JnxRpmMeasurementSet
Textual Convention: JnxRpmMeasurementSet Enumeration
Type Values:
1roundTripTime
2posRttJitter
3negRttJitter
4egress
5posEgressJitter
6negEgressJitter
7ingress
8posIngressJitter
9negIngressJitter
.1.3.6.1.4.1.2636.3.50.1.6.1.1
jnxRpmHistCalcSamples
The number of samples used in this calculations.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.6.1.2
jnxRpmHistCalcMin
The minimum of all the samples in the collection and measurement
set associated with this row. Values are provided in units
of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.6.1.3
jnxRpmHistCalcMax
The maximum of all the samples in the collection and measurement
set associated with this row. Values are provided in units
of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.6.1.4
jnxRpmHistCalcAverage
The average of all the samples in the collection and measurement
set associated with this row. Values are provided in units
of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.6.1.5
jnxRpmHistCalcPkToPk
The difference between the minimum and maximum of all the samples
in the collection and measurement set associated with this row.
Values are provided in units of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.6.1.6
jnxRpmHistCalcStdDev
The standard deviation calculated over all the samples
in the collection and measurement set associated with this row.
Values are provided in units of microseconds.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2636.3.50.1.6.1.7
jnxRpmHistCalcSum
The sum of all the samples in the collection and measurement set
associated with this row. Values are provided in units of
microseconds.
HCNUM-TCCounterBasedGauge64
Textual Convention: HCNUM-TCCounterBasedGauge64 Unsigned64
.1.3.6.1.4.1.2636.3.50.1.6.1.8