IT-WATCHDOGS-V4-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
8
Rows
8
Columns
75
.1.3.6.1.4.1.17373.4.1.2 · 1 row entry · 12 columns
Internal sensors for units
internalEntry entry .1.3.6.1.4.1.17373.4.1.2.1
Entry in the internalTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
internalIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.2.1.1
internalSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.2.1.2
internalName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.2.1.3
internalAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.2.1.4
internalTemp
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.2.1.5
internalHumidity
Humidity reading
%Integer32 .1.3.6.1.4.1.17373.4.1.2.1.6
internalDewPoint
Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.2.1.7
internalIO1
Current reading for Analog Input 1
Integer32 .1.3.6.1.4.1.17373.4.1.2.1.8
internalIO2
Current reading for Analog Input 2
Integer32 .1.3.6.1.4.1.17373.4.1.2.1.9
internalIO3
Current reading for Analog Input 3
Integer32 .1.3.6.1.4.1.17373.4.1.2.1.10
internalIO4
Current reading for Analog Input 4
Integer32 .1.3.6.1.4.1.17373.4.1.2.1.11
internalRelayState
Is the relay on?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.2.1.12
.1.3.6.1.4.1.17373.4.1.4 · 1 row entry · 5 columns
Remote Temperature Sensor
tempSensorEntry entry .1.3.6.1.4.1.17373.4.1.4.1
Entry in the tempSensorTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
tempSensorIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.4.1.1
tempSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.4.1.2
tempSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.4.1.3
tempSensorAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.4.1.4
tempSensorTemp
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.4.1.5
.1.3.6.1.4.1.17373.4.1.5 · 1 row entry · 8 columns
Remote Airflow, Humidity, Temperature and Dewpoint Sensor
airFlowSensorEntry entry .1.3.6.1.4.1.17373.4.1.5.1
Entry in the airFlowSensorTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
airFlowSensorIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.5.1.1
airFlowSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.5.1.2
airFlowSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.5.1.3
airFlowSensorAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.5.1.4
airFlowSensorTemp
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.5.1.5
airFlowSensorFlow
AFHT3 Airflow reading
Integer32 .1.3.6.1.4.1.17373.4.1.5.1.6
airFlowSensorHumidity
AFHT3 Humidity reading
%Integer32 .1.3.6.1.4.1.17373.4.1.5.1.7
airFlowSensorDewPoint
Current reading for Dew Point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.5.1.8
.1.3.6.1.4.1.17373.4.1.6 · 1 row entry · 7 columns
Remote Dew Point sensor
dewPointSensorEntry entry .1.3.6.1.4.1.17373.4.1.6.1
Entry in the dewPointSensorTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
dewPointSensorIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.6.1.1
dewPointSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.6.1.2
dewPointSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.6.1.3
dewPointSensorAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.6.1.4
dewPointSensorTemp
Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.6.1.5
dewPointSensorHumidity
Humidity reading
%Integer32 .1.3.6.1.4.1.17373.4.1.6.1.6
dewPointSensorDewPoint
Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.6.1.7
.1.3.6.1.4.1.17373.4.1.7 · 1 row entry · 7 columns
Remote CCAT sensor
ccatSensorEntry entry .1.3.6.1.4.1.17373.4.1.7.1
Entry in the ccatSensorTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
ccatSensorIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.7.1.1
ccatSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.7.1.2
ccatSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.7.1.3
ccatSensorAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.7.1.4
ccatSensorValue
CCAT sensor reading
Integer32 .1.3.6.1.4.1.17373.4.1.7.1.5
ccatSensorType
CCAT sensor type
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.7.1.6
ccatSensorDescription
CCAT sensor value description
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.7.1.7
.1.3.6.1.4.1.17373.4.1.8 · 1 row entry · 14 columns
Remote Temperature x 3, Humidity and Dewpoint Sensor
t3hdSensorEntry entry .1.3.6.1.4.1.17373.4.1.8.1
Entry in the t3hdSensorTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
t3hdSensorIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.8.1.1
t3hdSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.8.1.2
t3hdSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.8.1.3
t3hdSensorAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.8.1.4
t3hdSensorIntName
T3HD Sensor Internal Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.8.1.5
t3hdSensorIntTemp
Current reading for Internal Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.8.1.6
t3hdSensorIntHumidity
T3HD Sensor Internal Humidity
%Integer32 .1.3.6.1.4.1.17373.4.1.8.1.7
t3hdSensorIntDewPoint
Current reading for Internal DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.8.1.8
t3hdSensorExtAAvail
T3HD External A status: 0 = unplugged, 1 = normal operation, 2 = device error
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.8.1.9
t3hdSensorExtAName
T3HD External A Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.8.1.10
t3hdSensorExtATemp
Current reading for External Temperature A in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.8.1.11
t3hdSensorExtBAvail
T3HD External B status: 0 = unplugged, 1 = normal operation, 2 = device error
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.8.1.12
t3hdSensorExtBName
T3HD External B Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.8.1.13
t3hdSensorExtBTemp
Current reading for External Temperature B in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.8.1.14
.1.3.6.1.4.1.17373.4.1.9 · 1 row entry · 7 columns
Remote Temperature, Humidity and Dewpoint Sensor
thdSensorEntry entry .1.3.6.1.4.1.17373.4.1.9.1
Entry in the thdSensorTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
thdSensorIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.9.1.1
thdSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.9.1.2
thdSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.9.1.3
thdSensorAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.9.1.4
thdSensorTemp
Current reading for Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.9.1.5
thdSensorHumidity
THD Sensor Humidity
%Integer32 .1.3.6.1.4.1.17373.4.1.9.1.6
thdSensorDewPoint
Current reading for DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo
0.1 DegreesInteger32 .1.3.6.1.4.1.17373.4.1.9.1.7
.1.3.6.1.4.1.17373.4.1.10 · 1 row entry · 15 columns
Remote Power Manager Sensor
rpmSensorEntry entry .1.3.6.1.4.1.17373.4.1.10.1
Entry in the rpmSensorTable table: each entry contains an index and other sensor details
Indexes
No indexes recorded
Column Syntax OID
rpmSensorIndex
Table entry index value
Integer32 .1.3.6.1.4.1.17373.4.1.10.1.1
rpmSensorSerial
Serial Number
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.10.1.2
rpmSensorName
Friendly Name
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.17373.4.1.10.1.3
rpmSensorAvail
Is device currently plugged in?
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.4
rpmSensorEnergy
RPM Sensor Accumulated Energy
kWhSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.5
rpmSensorVoltage
RPM Sensor Voltage
Volts (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.6
rpmSensorVoltageMax
RPM Sensor Voltage (Max)
Volts (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.7
rpmSensorVoltageMin
RPM Sensor Voltage (Min)
Volts (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.8
rpmSensorVoltagePeak
RPM Sensor Voltage (Peak)
VoltsSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.9
rpmSensorCurrent
RPM Sensor Current reading in deciAmps
0.1 Amps (rms)SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.10
rpmSensorRealPower
RPM Sensor Real Power
WattsSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.11
rpmSensorApparentPower
RPM Sensor Apparent Power
Volt-AmpsSNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.12
rpmSensorPowerFactor
RPM Sensor Power Factor
%SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.13
rpmSensorOutlet1
RPM Sensor Outlet 1 State: 0 = off, 1 = on
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.17373.4.1.10.1.14
rpmSensorOutlet2
RPM Sensor Outlet 2 State: 0 = off, 1 = on
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295