ISILON-TRAP-MIB
Traps for Isilon Systems OneFS operating system.
isilonTraps
1.3.6.1.4.1.12124.250
Imported Objects
| ISILON-MIB | isilon |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter64 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
Objects (134)
|
|
.1.3.6.1.4.1.12124.250 |
|
|
|
.1.3.6.1.4.1.12124.250.10 |
|
|
|
.1.3.6.1.4.1.12124.250.10.1 |
|
|
|
.1.3.6.1.4.1.12124.250.10.2 |
|
|
|
.1.3.6.1.4.1.12124.250.10.20 |
|
|
|
.1.3.6.1.4.1.12124.250.10.21 |
|
|
|
.1.3.6.1.4.1.12124.250.10.3 |
|
|
|
.1.3.6.1.4.1.12124.250.10.4 |
|
|
|
.1.3.6.1.4.1.12124.250.11 |
|
|
|
.1.3.6.1.4.1.12124.250.11.1 |
|
|
|
.1.3.6.1.4.1.12124.250.11.2 |
|
|
|
.1.3.6.1.4.1.12124.250.11.20 |
|
|
|
.1.3.6.1.4.1.12124.250.11.3 |
|
|
|
.1.3.6.1.4.1.12124.250.11.4 |
|
|
|
.1.3.6.1.4.1.12124.250.11.5 |
|
|
|
.1.3.6.1.4.1.12124.250.11.6 |
|
|
|
.1.3.6.1.4.1.12124.250.12 |
|
|
|
.1.3.6.1.4.1.12124.250.12.1 |
|
|
|
.1.3.6.1.4.1.12124.250.12.2 |
|
|
|
.1.3.6.1.4.1.12124.250.12.3 |
|
|
|
.1.3.6.1.4.1.12124.250.13 |
|
|
|
.1.3.6.1.4.1.12124.250.13.1 |
|
|
|
.1.3.6.1.4.1.12124.250.13.2 |
|
|
|
.1.3.6.1.4.1.12124.250.14 |
|
|
|
.1.3.6.1.4.1.12124.250.14.1 |
|
|
|
.1.3.6.1.4.1.12124.250.14.2 |
|
|
|
.1.3.6.1.4.1.12124.250.14.20 |
|
|
|
.1.3.6.1.4.1.12124.250.14.21 |
|
|
|
.1.3.6.1.4.1.12124.250.15 |
|
|
|
.1.3.6.1.4.1.12124.250.15.1 |
|
|
|
.1.3.6.1.4.1.12124.250.15.10 |
|
|
|
.1.3.6.1.4.1.12124.250.15.11 |
|
|
|
.1.3.6.1.4.1.12124.250.15.12 |
|
|
|
.1.3.6.1.4.1.12124.250.15.13 |
|
|
|
.1.3.6.1.4.1.12124.250.15.15 |
|
|
|
.1.3.6.1.4.1.12124.250.15.2 |
|
|
|
.1.3.6.1.4.1.12124.250.15.3 |
|
|
|
.1.3.6.1.4.1.12124.250.15.5 |
|
|
|
.1.3.6.1.4.1.12124.250.15.6 |
|
|
|
.1.3.6.1.4.1.12124.250.15.7 |
|
|
|
.1.3.6.1.4.1.12124.250.15.8 |
|
|
|
.1.3.6.1.4.1.12124.250.15.9 |
|
|
|
.1.3.6.1.4.1.12124.250.16 |
|
|
|
.1.3.6.1.4.1.12124.250.16.1 |
|
|
|
.1.3.6.1.4.1.12124.250.16.2 |
|
|
|
.1.3.6.1.4.1.12124.250.16.20 |
|
|
|
.1.3.6.1.4.1.12124.250.17 |
|
|
|
.1.3.6.1.4.1.12124.250.17.1 |
|
|
|
.1.3.6.1.4.1.12124.250.17.2 |
|
|
|
.1.3.6.1.4.1.12124.250.17.20 |
|
|
|
.1.3.6.1.4.1.12124.250.17.21 |
|
|
|
.1.3.6.1.4.1.12124.250.17.22 |
|
|
|
.1.3.6.1.4.1.12124.250.17.23 |
|
|
|
.1.3.6.1.4.1.12124.250.17.3 |
|
|
|
.1.3.6.1.4.1.12124.250.17.4 |
|
|
|
.1.3.6.1.4.1.12124.250.17.5 |
|
|
|
.1.3.6.1.4.1.12124.250.17.6 |
|
|
|
.1.3.6.1.4.1.12124.250.17.7 |
|
|
|
.1.3.6.1.4.1.12124.250.18 |
|
|
|
.1.3.6.1.4.1.12124.250.18.1 |
|
|
|
.1.3.6.1.4.1.12124.250.18.20 |
|
|
|
.1.3.6.1.4.1.12124.250.19 |
|
|
|
.1.3.6.1.4.1.12124.250.19.1 |
|
|
|
.1.3.6.1.4.1.12124.250.19.1.1 |
|
|
|
.1.3.6.1.4.1.12124.250.19.10 |
|
|
|
.1.3.6.1.4.1.12124.250.19.2 |
|
|
|
.1.3.6.1.4.1.12124.250.19.20 |
|
|
|
.1.3.6.1.4.1.12124.250.19.50 |
|
|
|
.1.3.6.1.4.1.12124.250.19.51 |
|
|
|
.1.3.6.1.4.1.12124.250.19.52 |
|
|
|
.1.3.6.1.4.1.12124.250.19.53 |
|
|
|
.1.3.6.1.4.1.12124.250.20 |
|
|
|
.1.3.6.1.4.1.12124.250.20.1 |
|
|
|
.1.3.6.1.4.1.12124.250.20.2 |
|
|
|
.1.3.6.1.4.1.12124.250.20.20 |
|
|
|
.1.3.6.1.4.1.12124.250.20.3 |
|
|
|
.1.3.6.1.4.1.12124.250.20.4 |
|
|
|
.1.3.6.1.4.1.12124.250.21 |
|
|
|
.1.3.6.1.4.1.12124.250.21.1 |
|
|
|
.1.3.6.1.4.1.12124.250.21.1.1 |
|
|
|
.1.3.6.1.4.1.12124.250.21.1.2 |
|
|
|
.1.3.6.1.4.1.12124.250.21.10 |
|
|
|
.1.3.6.1.4.1.12124.250.21.10.1 |
|
|
|
.1.3.6.1.4.1.12124.250.21.10.2 |
|
|
|
.1.3.6.1.4.1.12124.250.21.11 |
|
|
|
.1.3.6.1.4.1.12124.250.21.11.1 |
|
|
|
.1.3.6.1.4.1.12124.250.21.11.2 |
|
|
|
.1.3.6.1.4.1.12124.250.21.12 |
|
|
|
.1.3.6.1.4.1.12124.250.21.13 |
|
|
|
.1.3.6.1.4.1.12124.250.21.14 |
|
|
|
.1.3.6.1.4.1.12124.250.21.15 |
|
|
|
.1.3.6.1.4.1.12124.250.21.16 |
|
|
|
.1.3.6.1.4.1.12124.250.21.16.1 |
|
|
|
.1.3.6.1.4.1.12124.250.21.16.2 |
|
|
|
.1.3.6.1.4.1.12124.250.21.2 |
|
|
|
.1.3.6.1.4.1.12124.250.21.2.1 |
|
|
|
.1.3.6.1.4.1.12124.250.21.2.2 |
|
|
|
.1.3.6.1.4.1.12124.250.22 |
|
|
|
.1.3.6.1.4.1.12124.250.22.1 |
|
|
|
.1.3.6.1.4.1.12124.250.22.2 |
|
|
|
.1.3.6.1.4.1.12124.250.23 |
|
|
|
.1.3.6.1.4.1.12124.250.23.1 |
|
|
|
.1.3.6.1.4.1.12124.250.23.2 |
|
|
|
.1.3.6.1.4.1.12124.250.23.3 |
|
|
|
.1.3.6.1.4.1.12124.250.23.4 |
|
|
|
.1.3.6.1.4.1.12124.250.23.5 |
|
|
|
.1.3.6.1.4.1.12124.250.23.6 |
|
|
|
.1.3.6.1.4.1.12124.250.23.7 |
|
|
|
.1.3.6.1.4.1.12124.250.23.8 |
|
|
|
.1.3.6.1.4.1.12124.250.24 |
|
|
|
.1.3.6.1.4.1.12124.250.24.1 |
|
|
|
.1.3.6.1.4.1.12124.250.24.2 |
|
|
|
.1.3.6.1.4.1.12124.250.24.3 |
|
|
|
.1.3.6.1.4.1.12124.250.24.4 |
|
|
|
.1.3.6.1.4.1.12124.250.24.5 |
|
|
|
.1.3.6.1.4.1.12124.250.50 |
|
|
|
Integer32 | .1.3.6.1.4.1.12124.250.50.1 |
|
|
OctetString | .1.3.6.1.4.1.12124.250.50.10 |
|
|
OctetString | .1.3.6.1.4.1.12124.250.50.11 |
|
|
SNMPv2-SMICounter64 | .1.3.6.1.4.1.12124.250.50.12 |
|
|
Integer32 | .1.3.6.1.4.1.12124.250.50.13 |
|
|
OctetString | .1.3.6.1.4.1.12124.250.50.14 |
|
|
OctetString | .1.3.6.1.4.1.12124.250.50.15 |
|
|
Integer32 | .1.3.6.1.4.1.12124.250.50.16 |
|
|
Integer32 | .1.3.6.1.4.1.12124.250.50.2 |
|
|
OctetString | .1.3.6.1.4.1.12124.250.50.3 |
|
|
ObjectIdentifier | .1.3.6.1.4.1.12124.250.50.4 |
|
|
Integer32 | .1.3.6.1.4.1.12124.250.50.5 |
|
|
OctetString | .1.3.6.1.4.1.12124.250.50.6 |
|
|
Integer32 | .1.3.6.1.4.1.12124.250.50.7 |
|
|
OctetString | .1.3.6.1.4.1.12124.250.50.8 |
|
|
Integer32 | .1.3.6.1.4.1.12124.250.50.9 |
|
|
.1.3.6.1.4.1.12124.250.51 |
|
|
|
.1.3.6.1.4.1.12124.250.52 |
Notifications / Traps (181)
| Name | OID | Description |
|---|---|---|
|
|
.1.3.6.1.4.1.12124.250.10.1.3 |
A critical node status event has occurred. |
|
|
.1.3.6.1.4.1.12124.250.10.1.7 |
A node status event has occurred. |
|
|
.1.3.6.1.4.1.12124.250.10.2.3 |
A disk-only node has gone offline and cannot be contacted by the cluster. |
|
|
.1.3.6.1.4.1.12124.250.10.20.7 |
A node is being rebooted. |
|
|
.1.3.6.1.4.1.12124.250.10.21.3 |
Critical node status events are occurring |
|
|
.1.3.6.1.4.1.12124.250.10.21.5 |
Warning node status events are occurring |
|
|
.1.3.6.1.4.1.12124.250.10.3.7 |
A node is being shut down or rebooted. |
|
|
.1.3.6.1.4.1.12124.250.10.4.3 |
Shut down or reboot failed for a node. |
|
|
.1.3.6.1.4.1.12124.250.11.1.3 |
A partition is over the critical threshold percentage. |
|
|
.1.3.6.1.4.1.12124.250.11.1.5 |
A partition is over the warning threshold percentage. |
|
|
.1.3.6.1.4.1.12124.250.11.1.7 |
A partition is over the info threshold percentage. |
|
|
.1.3.6.1.4.1.12124.250.11.2.3 |
The /ifs partition is near capacity. |
|
|
.1.3.6.1.4.1.12124.250.11.2.5 |
The /ifs partition is near capacity. |
|
|
.1.3.6.1.4.1.12124.250.11.20.3 |
Filesystem issues are occurring at a critical level |
|
|
.1.3.6.1.4.1.12124.250.11.20.5 |
Filesystem issues are occurring at a warning level |
|
|
.1.3.6.1.4.1.12124.250.11.3.3 |
A critical /ifs filesystem error has occurred |
|
|
.1.3.6.1.4.1.12124.250.11.3.5 |
A warning-level /ifs filesystem error has occurred |
|
|
.1.3.6.1.4.1.12124.250.11.3.7 |
An /ifs filesystem error has occurred. |
|
|
.1.3.6.1.4.1.12124.250.11.4.3 |
A disk pool is near capacity. |
|
|
.1.3.6.1.4.1.12124.250.11.4.5 |
A disk pool is near capacity. |
|
|
.1.3.6.1.4.1.12124.250.11.5.5 |
The SmartPools upgrade has not completed. |
|
|
.1.3.6.1.4.1.12124.250.11.6.1 |
The SSD drives are at capacity. |
|
|
.1.3.6.1.4.1.12124.250.11.6.2 |
The SSD drives are near capacity. |
|
|
.1.3.6.1.4.1.12124.250.11.6.3 |
The SSD drives are near capacity. |
|
|
.1.3.6.1.4.1.12124.250.12.1.7 |
SmartQuotas threshold violation |
|
|
.1.3.6.1.4.1.12124.250.12.2.5 |
SmartQuotas threshold notification failed |
|
|
.1.3.6.1.4.1.12124.250.12.3.5 |
SmartQuotas error |
|
|
.1.3.6.1.4.1.12124.250.13.1.5 |
Snapshot error |
|
|
.1.3.6.1.4.1.12124.250.13.2.3 |
Snapshot reserve space is over its critical limit |
|
|
.1.3.6.1.4.1.12124.250.13.2.5 |
Snapshot reserve space is over its warning limit |
|
|
.1.3.6.1.4.1.12124.250.14.1.3 |
SyncIQ event |
|
|
.1.3.6.1.4.1.12124.250.14.1.5 |
SyncIQ event |
|
|
.1.3.6.1.4.1.12124.250.14.2.5 |
SyncIQ error |
|
|
.1.3.6.1.4.1.12124.250.14.20.3 |
SyncIQ policy errors are occurring |
|
|
.1.3.6.1.4.1.12124.250.14.20.5 |
SyncIQ policy errors are occurring |
|
|
.1.3.6.1.4.1.12124.250.14.21.3 |
SyncIQ errors are occurring for target |
|
|
.1.3.6.1.4.1.12124.250.14.21.5 |
SyncIQ errors are occurring for target |
|
|
.1.3.6.1.4.1.12124.250.15.1.1 |
The cluster encountered one or more job failures. |
|
|
.1.3.6.1.4.1.12124.250.15.1.3 |
The cluster encountered one or more job failures. |
|
|
.1.3.6.1.4.1.12124.250.15.1.5 |
The cluster encountered one or more job failures. |
|
|
.1.3.6.1.4.1.12124.250.15.1.7 |
The cluster encountered one or more job failures. |
|
|
.1.3.6.1.4.1.12124.250.15.10.5 |
A node has exceeded the Warning-level CPU utilization. |
|
|
.1.3.6.1.4.1.12124.250.15.10.7 |
A node has exceeded the Info-level CPU utilization. |
|
|
.1.3.6.1.4.1.12124.250.15.11.7 |
Mountd denied client mount request |
|
|
.1.3.6.1.4.1.12124.250.15.12.7 |
Mountd host lookup failed |
|
|
.1.3.6.1.4.1.12124.250.15.13.3 |
Cluster contains a mix of encrypting nodes and non-encrypting nodes |
|
|
.1.3.6.1.4.1.12124.250.15.15.1 |
64bit to 32bit cookie translation failed |
|
|
.1.3.6.1.4.1.12124.250.15.2.3 |
Cluster is in need of restripe but FlexProtect is not running |
|
|
.1.3.6.1.4.1.12124.250.15.2.5 |
Cluster is in need of restripe but FlexProtect is not running |
|
|
.1.3.6.1.4.1.12124.250.15.2.7 |
Cluster is in need of restripe but FlexProtect is not running |
|
|
.1.3.6.1.4.1.12124.250.15.3.3 |
AVScan found an infected file |
|
|
.1.3.6.1.4.1.12124.250.15.3.5 |
AVScan found an infected file |
|
|
.1.3.6.1.4.1.12124.250.15.3.7 |
AVScan found an infected file |
|
|
.1.3.6.1.4.1.12124.250.15.5.5 |
MCP reports a process has failed on a node |
|
|
.1.3.6.1.4.1.12124.250.15.6.5 |
MCP killed a process on a node |
|
|
.1.3.6.1.4.1.12124.250.15.7.5 |
One or more licenses has expired |
|
|
.1.3.6.1.4.1.12124.250.15.7.7 |
One or more licenses is about to expire |
|
|
.1.3.6.1.4.1.12124.250.15.8.5 |
A firmware update was not completely applied |
|
|
.1.3.6.1.4.1.12124.250.15.9.3 |
Test event |
|
|
.1.3.6.1.4.1.12124.250.16.1.3 |
No ICAP servers configured for AVScan |
|
|
.1.3.6.1.4.1.12124.250.16.1.5 |
No ICAP servers configured for AVScan |
|
|
.1.3.6.1.4.1.12124.250.16.1.7 |
No ICAP servers configured for AVScan |
|
|
.1.3.6.1.4.1.12124.250.16.2.3 |
AVscan has encountered an error |
|
|
.1.3.6.1.4.1.12124.250.16.2.5 |
AVscan has encountered an error |
|
|
.1.3.6.1.4.1.12124.250.16.2.7 |
AVscan has encountered an error |
|
|
.1.3.6.1.4.1.12124.250.16.20.3 |
AVScan is detecting problems |
|
|
.1.3.6.1.4.1.12124.250.16.20.5 |
AVScan is detecting problems |
|
|
.1.3.6.1.4.1.12124.250.16.20.7 |
AVscan is detecting critical problems |
|
|
.1.3.6.1.4.1.12124.250.17.1.3 |
Windows ADS time skew outside limits. |
|
|
.1.3.6.1.4.1.12124.250.17.2.3 |
Windows share permissions upgrade failed |
|
|
.1.3.6.1.4.1.12124.250.17.20.3 |
There are problems with Windows networking components |
|
|
.1.3.6.1.4.1.12124.250.17.20.5 |
There are problems with Windows networking components |
|
|
.1.3.6.1.4.1.12124.250.17.21.3 |
There are problems with the Windows ID map |
|
|
.1.3.6.1.4.1.12124.250.17.21.5 |
There are problems with the Windows ID map |
|
|
.1.3.6.1.4.1.12124.250.17.22.3 |
There are problems with Windows authentication components |
|
|
.1.3.6.1.4.1.12124.250.17.22.5 |
There are problems with Windows authentication components |
|
|
.1.3.6.1.4.1.12124.250.17.23.3 |
There are problems with upgrading authentication components |
|
|
.1.3.6.1.4.1.12124.250.17.3.5 |
Connectivity to the Windows Time server was lost |
|
|
.1.3.6.1.4.1.12124.250.17.4.3 |
Windows ID map range is full. Authentication may fail. |
|
|
.1.3.6.1.4.1.12124.250.17.5.3 |
Active Directory connectivity failure |
|
|
.1.3.6.1.4.1.12124.250.17.5.5 |
Active Directory connectivity issue |
|
|
.1.3.6.1.4.1.12124.250.17.6.3 |
LWIO Parameter Invalid |
|
|
.1.3.6.1.4.1.12124.250.17.7.2 |
Windows networking |
|
|
.1.3.6.1.4.1.12124.250.17.7.3 |
Windows networking |
|
|
.1.3.6.1.4.1.12124.250.18.1.3 |
A network interface is down |
|
|
.1.3.6.1.4.1.12124.250.18.1.5 |
A network interface is degraded or down |
|
|
.1.3.6.1.4.1.12124.250.18.20.3 |
Critical network problems are occurring |
|
|
.1.3.6.1.4.1.12124.250.18.20.5 |
Warning network problems are occurring |
|
|
.1.3.6.1.4.1.12124.250.19.1.1.3 |
There is a message concerning a hardware faliure |
|
|
.1.3.6.1.4.1.12124.250.19.1.1.5 |
There is a message concerning a potential hardware faliure |
|
|
.1.3.6.1.4.1.12124.250.19.1.3 |
A critical hardware error has occurred. |
|
|
.1.3.6.1.4.1.12124.250.19.1.5 |
A node has a hardware error |
|
|
.1.3.6.1.4.1.12124.250.19.1.7 |
A hardware problem is occurring. |
|
|
.1.3.6.1.4.1.12124.250.19.10.3 |
The expander is offline |
|
|
.1.3.6.1.4.1.12124.250.19.2.3 |
Power Supply AC Failiure. |
|
|
.1.3.6.1.4.1.12124.250.19.20.1 |
There are hardware issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.20.3 |
There are hardware issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.20.5 |
There are hardware issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.50.1 |
There are sensor issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.50.3 |
There are sensor issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.50.5 |
There are sensor issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.51.1 |
There are fan issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.51.3 |
There are fan issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.51.5 |
There are fan issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.52.1 |
There are temp issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.52.3 |
There are temp issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.52.5 |
There are temp issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.53.1 |
There are voltage issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.53.3 |
There are voltage issues on a node |
|
|
.1.3.6.1.4.1.12124.250.19.53.5 |
There are voltage issues on a node |
|
|
.1.3.6.1.4.1.12124.250.20.1.1 |
A node has detected a problem with a drive |
|
|
.1.3.6.1.4.1.12124.250.20.1.3 |
A node has detected a problem with a drive |
|
|
.1.3.6.1.4.1.12124.250.20.1.5 |
A node has detected a problem with a drive |
|
|
.1.3.6.1.4.1.12124.250.20.2.3 |
Unhealthy boot disks, mirror is degraded. |
|
|
.1.3.6.1.4.1.12124.250.20.2.5 |
Unhealthy boot disks, mirror is degraded. |
|
|
.1.3.6.1.4.1.12124.250.20.20.3 |
A node's disks are having critical problems |
|
|
.1.3.6.1.4.1.12124.250.20.20.5 |
A node's disks are having warning level problems |
|
|
.1.3.6.1.4.1.12124.250.20.3.3 |
A node's disks are having problems |
|
|
.1.3.6.1.4.1.12124.250.20.4.3 |
Error creating mirror on bootdisks. |
|
|
.1.3.6.1.4.1.12124.250.21.1.1.3 |
Power supply current over critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.1.1.5 |
Power supply current over warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.1.2.3 |
Power supply current under critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.1.2.5 |
Power supply current under warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.10.1.3 |
A node's voltage is over critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.10.1.5 |
A node's voltage is over warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.10.1.7 |
A node's voltage is over a threshold |
|
|
.1.3.6.1.4.1.12124.250.21.10.2.3 |
A node's voltage is under critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.10.2.5 |
A node's voltage is under warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.10.2.7 |
A node's voltage is under a threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.1.1 |
A node's temperature is over emergency threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.1.3 |
A node's temperature is over critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.1.5 |
A node's temperature is over warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.1.7 |
A node's temperature is over a threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.2.1 |
A node's temperature is under emergency threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.2.3 |
A node's temperature is under critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.2.5 |
A node's temperature is under warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.11.2.7 |
A node's temperature is under a threshold |
|
|
.1.3.6.1.4.1.12124.250.21.12.3 |
A node has a power supply problem |
|
|
.1.3.6.1.4.1.12124.250.21.12.5 |
A node has a power supply monitoring problem |
|
|
.1.3.6.1.4.1.12124.250.21.13.3 |
A node is low on memory |
|
|
.1.3.6.1.4.1.12124.250.21.14.3 |
A node is at 100% CPU utilization |
|
|
.1.3.6.1.4.1.12124.250.21.15.1 |
A sensor failed |
|
|
.1.3.6.1.4.1.12124.250.21.15.2 |
A sensor is failing |
|
|
.1.3.6.1.4.1.12124.250.21.16.1.1 |
A node's current is over emergency threshold |
|
|
.1.3.6.1.4.1.12124.250.21.16.1.3 |
A node's current is over critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.16.1.5 |
A node's current is over warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.16.1.7 |
A node's current is over a threshold |
|
|
.1.3.6.1.4.1.12124.250.21.16.2.1 |
A node's current is under emergency threshold |
|
|
.1.3.6.1.4.1.12124.250.21.16.2.3 |
A node's current is under critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.16.2.5 |
A node's current is under warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.16.2.7 |
A node's current is under a threshold |
|
|
.1.3.6.1.4.1.12124.250.21.2.1.3 |
A node's fan is over critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.2.1.5 |
A node's fan is over warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.2.1.7 |
A node's fan is over warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.2.2.3 |
A node's fan is under critical threshold |
|
|
.1.3.6.1.4.1.12124.250.21.2.2.5 |
A node's fan is under warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.2.2.7 |
A node's fan is under warning threshold |
|
|
.1.3.6.1.4.1.12124.250.21.2.3 |
A node's fan failed |
|
|
.1.3.6.1.4.1.12124.250.21.2.5 |
A node's fan monitor is about to fail |
|
|
.1.3.6.1.4.1.12124.250.22.1.5 |
A SAS PHY error was detected in the expander. |
|
|
.1.3.6.1.4.1.12124.250.22.1.7 |
A SAS PHY error was detected in the controller. |
|
|
.1.3.6.1.4.1.12124.250.22.2.1 |
There are storage transport issues on a node |
|
|
.1.3.6.1.4.1.12124.250.22.2.3 |
There are storage transport issues on a node |
|
|
.1.3.6.1.4.1.12124.250.22.2.5 |
There are storage transport issues on a node |
|
|
.1.3.6.1.4.1.12124.250.23.1.3 |
CloudPools network issues |
|
|
.1.3.6.1.4.1.12124.250.23.2.3 |
CloudPools authentication issues |
|
|
.1.3.6.1.4.1.12124.250.23.3.3 |
CloudPools authorization issues |
|
|
.1.3.6.1.4.1.12124.250.23.4.3 |
CloudPools bucket not found issues |
|
|
.1.3.6.1.4.1.12124.250.23.5.3 |
CloudPools Object not found issues |
|
|
.1.3.6.1.4.1.12124.250.23.6.1 |
CloudPools data corruption integrity emergency issues |
|
|
.1.3.6.1.4.1.12124.250.23.7.3 |
CloudPools no usable account found for the policy, cloudpool |
|
|
.1.3.6.1.4.1.12124.250.23.8.3 |
CloudPools Certificate issues |
|
|
.1.3.6.1.4.1.12124.250.24.1.7 |
An upgrade or rollback has been started. |
|
|
.1.3.6.1.4.1.12124.250.24.2.7 |
An upgrade or rollback has finished. |
|
|
.1.3.6.1.4.1.12124.250.24.3.3 |
Upgrade cluster event. |
|
|
.1.3.6.1.4.1.12124.250.24.3.5 |
Upgrade cluster event. |
|
|
.1.3.6.1.4.1.12124.250.24.3.7 |
Upgrade cluster event. |
|
|
.1.3.6.1.4.1.12124.250.24.4.3 |
Upgrade node event. |
|
|
.1.3.6.1.4.1.12124.250.24.4.5 |
Upgrade node event. |
|
|
.1.3.6.1.4.1.12124.250.24.4.7 |
Upgrade node event. |
|
|
.1.3.6.1.4.1.12124.250.24.5.7 |
Upgrade rollback start. |