IPI-CMM-IPMI-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
26
.1.3.6.1.4.1.36673.100.1.5.1 · 1 row entry · 11 columns
A list of entries containing sensor information
for BMC controlled devices.
cmmIpmiDeviceSensorEntry entry .1.3.6.1.4.1.36673.100.1.5.1.1
A list of entries containing sensor information
for BMC controlled devices.
Indexes
cmmIpmiDeviceSensorIndex
Column Syntax OID
cmmIpmiDeviceSensorIndex
The unique sensor index number.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.36673.100.1.5.1.1.1
cmmIpmiDeviceSensorName
The name of IPMI device sensor.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.1.1.2
cmmIpmiDeviceSensorValue
The value read for IPMI device sensor.
Unit: Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
'-100002' indicates not applicable
0.001 unitInteger32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.36673.100.1.5.1.1.3
cmmIpmiDeviceSensorUnits
The unit of the value read for IPMI device sensor.
For Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.1.1.4
cmmIpmiDeviceSensorState
The operating state of IPMI device sensor.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.1.1.5
cmmIpmiDeviceSensorLowerNonRecover
The IPMI device sensor lower non recover value.
Unit: Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
'-100002' indicates not applicable
0.001 unitInteger32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.36673.100.1.5.1.1.6
cmmIpmiDeviceSensorLowerCritical
The IPMI device sensor lower critical value.
Unit: Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
'-100002' indicates not applicable
0.001 unitInteger32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.36673.100.1.5.1.1.7
cmmIpmiDeviceSensorLowerNonCritical
The IPMI device sensor lower non critical value.
Unit: Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
-100002' indicates not applicable
0.001 unitInteger32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.36673.100.1.5.1.1.8
cmmIpmiDeviceSensorUpperNonCritical
The IPMI device sensor upper non critical value.
Unit: Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
'-100002' indicates not applicable
0.001 unitInteger32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.36673.100.1.5.1.1.9
cmmIpmiDeviceSensorUpperCritical
The IPMI device sensor upper critical value.
Unit: Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
'-100002' indicates not applicable
0.001 unitInteger32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.36673.100.1.5.1.1.10
cmmIpmiDeviceSensorUpperNonRecover
The IPMI device sensor upper non recover value.
Unit: Temperature in degree C, Current in Amps,
Power in Watts, Voltage in Volts, Fan-Speed in RPM.
'-100002' indicates not applicable
0.001 unitInteger32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.36673.100.1.5.1.1.11
.1.3.6.1.4.1.36673.100.1.5.2 · 1 row entry · 15 columns
A list of entries containing FRU information
for BMC controlled devices.
cmmIpmiDeviceFRUEntry entry .1.3.6.1.4.1.36673.100.1.5.2.1
A list of entries containing FRU information
for BMC controlled devices.
Indexes
cmmIpmiDeviceFRUIndex
Column Syntax OID
cmmIpmiDeviceFRUIndex
The unique FRU index number.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.36673.100.1.5.2.1.1
cmmIpmiDeviceBoardMfgDate
Board manufacturing date.
Blank indicates unavailable
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.36673.100.1.5.2.1.2
cmmIpmiDeviceBoardMfg
Board manufacturer name.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.3
cmmIpmiDeviceBoardProduct
Board product name.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.4
cmmIpmiDeviceBoardSerial
Board Serial number.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.5
cmmIpmiDeviceBoardPartNum
Board Part number.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.6
cmmIpmiDeviceProductManufacturer
Product manufacturer name.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.7
cmmIpmiDeviceProductName
Product name.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.8
cmmIpmiDeviceProductPartNum
Product part number.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.9
cmmIpmiDeviceProductVersion
Product version number.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.10
cmmIpmiDeviceProductSerial
Product serial number.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.11
cmmIpmiDeviceProductAssetTag
Product asset tag number.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.12
cmmIpmiDeviceProductExtraInfo
Product extra information.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.13
cmmIpmiDeviceProductExtraInfo2
Product extra information.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.14
cmmIpmiDeviceDescription
Device Description.
Blank indicates unavailable
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.36673.100.1.5.2.1.15