IOMEGANAS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
8
Rows
8
Columns
37
ioTable
table.1.3.6.1.4.1.11369.10.2.1
·
1 row entry
·
13 columns
A table of disk I/O performance.
An entry of one disk I/O performance.
Indexes
ioIndex
| Column | Syntax | OID |
|---|---|---|
|
ioIndex
ioIndex
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.2.1.1.1 |
|
diskName
Disk names such as sda and so on
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.2 |
|
ioMgrs
Read merges per second.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.3 |
|
ioMgws
Write merges per second.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.4 |
|
ioReqrs
Read io requests per second.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.5 |
|
ioReqws
Write io requests per second.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.6 |
|
ioKbrs
Kilobytes read per second.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.7 |
|
ioKbws
Kilobytes written per second.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.8 |
|
ioAvgQueue
Average queue length.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.9 |
|
ioAvgWait
Average waiting time (queue + service)
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.10 |
|
ioAvgSvc
Average service time at disk.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.11 |
|
ioAvgUtil
Average disk utilization.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.12 |
|
ioCpuTime
Percentage of CPU time during which I/O requests were issued to the device.
|
OctetString | .1.3.6.1.4.1.11369.10.2.1.1.13 |
bkupTable
table.1.3.6.1.4.1.11369.10.3.1
·
1 row entry
·
4 columns
A table of backup status.
An entry of backup status.
Indexes
bkupIndex
| Column | Syntax | OID |
|---|---|---|
|
bkupIndex
Record backup status
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.3.1.1.1 |
|
bkupClient
Client Name
|
OctetString | .1.3.6.1.4.1.11369.10.3.1.1.2 |
|
bkupltStatus
Last backup status
|
OctetString | .1.3.6.1.4.1.11369.10.3.1.1.3 |
|
bkupTotalSpace
Total space
|
OctetString | .1.3.6.1.4.1.11369.10.3.1.1.4 |
conTable
table.1.3.6.1.4.1.11369.10.3.3
·
1 row entry
·
3 columns
Table for connected client count
Entry for connected client count
Indexes
conIndex
| Column | Syntax | OID |
|---|---|---|
|
conIndex
Index for entry
|
Integer32 Constraints: range: -2147483648-2147483647 |
.1.3.6.1.4.1.11369.10.3.3.1.1 |
|
conCount
Connected client count for a given protocol
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.3.3.1.2 |
|
conProtocol
Protocol used by this kind of clients
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.11369.10.3.3.1.3 |
diskTable
table.1.3.6.1.4.1.11369.10.4.3
·
1 row entry
·
4 columns
The table of disks that build the RAID.
An entry of one disk.
Indexes
diskIndex
| Column | Syntax | OID |
|---|---|---|
|
diskIndex
Index of disk entry
|
Integer32 Constraints: range: -2147483648-2147483647 |
.1.3.6.1.4.1.11369.10.4.3.1.1 |
|
diskID
ID of disk in array
|
OctetString | .1.3.6.1.4.1.11369.10.4.3.1.2 |
|
diskSize
Capacity of disk
|
OctetString | .1.3.6.1.4.1.11369.10.4.3.1.3 |
|
diskStatus
Status of Disk. There are four status:
NORMAL FOREIGN FAULTED MISSING |
OctetString | .1.3.6.1.4.1.11369.10.4.3.1.4 |
usbTable
table.1.3.6.1.4.1.11369.10.5.1
·
1 row entry
·
4 columns
Table of connected usb devices.
Entry for connected USB device
Indexes
usbIndex
| Column | Syntax | OID |
|---|---|---|
|
usbIndex
Index for entry in the table
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.5.1.1.1 |
|
usbManufacture
Manufucture of the device
|
OctetString Constraints: range: 0-255 |
.1.3.6.1.4.1.11369.10.5.1.1.2 |
|
usbModel
Model of the USB device
|
OctetString Constraints: range: 0-255 |
.1.3.6.1.4.1.11369.10.5.1.1.3 |
|
usbType
USB device type(such UPS(3), PTP(6), printer(7) and so on)
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.5.1.1.4 |
fanTable
table.1.3.6.1.4.1.11369.10.6.1
·
1 row entry
·
3 columns
Table for fan sensors
Entry for fan sensor
Indexes
fanIndex
| Column | Syntax | OID |
|---|---|---|
|
fanIndex
Index for the entry
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.6.1.1.1 |
|
fanName
Name of the fan sensor
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.11369.10.6.1.1.2 |
|
fanValue
Rotation speed of the fan in RPM
|
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11369.10.6.1.1.3 |
tempTable
table.1.3.6.1.4.1.11369.10.6.2
·
1 row entry
·
3 columns
Table for temperature sensor
Entry for temperature sensor
Indexes
tempIndex
| Column | Syntax | OID |
|---|---|---|
|
tempIndex
Index for entry
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.6.2.1.1 |
|
tempName
Name of the temperature sensor
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.11369.10.6.2.1.2 |
|
tempValue
The temperature of the sensor in mC.
|
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11369.10.6.2.1.3 |
voltTable
table.1.3.6.1.4.1.11369.10.6.3
·
1 row entry
·
3 columns
Table for volt sensor
Entry for volt sensor
Indexes
voltIndex
| Column | Syntax | OID |
|---|---|---|
|
voltIndex
Index for the entry
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11369.10.6.3.1.1 |
|
voltName
Name of the volt sensor
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.11369.10.6.3.1.2 |
|
voltValue
The voltage in mV
|
SNMPv2-SMIGauge32 Textual Convention: SNMPv2-SMIGauge32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11369.10.6.3.1.3 |