ICT-SINE-WAVE-MIB

Imported Objects
RFC-1212 OBJECT-TYPE
RFC-1215 TRAP-TYPE
RFC1155-SMI enterprises IpAddress
RFC1213-MIB DisplayString
Objects (13)
ictPower .1.3.6.1.4.1.39145
inverter .1.3.6.1.4.1.39145.12
deviceModel mandatory RFC1213-MIBDisplayString .1.3.6.1.4.1.39145.12.1
inverterControl mandatory r/w Enumeration .1.3.6.1.4.1.39145.12.10
transferRelayStatus mandatory Enumeration .1.3.6.1.4.1.39145.12.11
deviceName mandatory RFC1213-MIBDisplayString .1.3.6.1.4.1.39145.12.2
deviceHardware mandatory Integer32 .1.3.6.1.4.1.39145.12.3
deviceFirmware mandatory RFC1213-MIBDisplayString .1.3.6.1.4.1.39145.12.4
deviceMacAddress mandatory RFC1213-MIBDisplayString .1.3.6.1.4.1.39145.12.5
batteryVoltage mandatory RFC1213-MIBDisplayString .1.3.6.1.4.1.39145.12.6
inverterVoltage mandatory RFC1213-MIBDisplayString .1.3.6.1.4.1.39145.12.7
inverterPower mandatory RFC1213-MIBDisplayString .1.3.6.1.4.1.39145.12.8
inverterStatus mandatory Enumeration .1.3.6.1.4.1.39145.12.9
Notifications / Traps (14)
NameOIDDescription
undervoltageAlarmTrap .1.3.6.1.4.1.39145.12.0.101
Trap generated when the Battery Input Undervoltage Alarm is triggered
overvoltageAlarmTrap .1.3.6.1.4.1.39145.12.0.102
Trap generated when the Battery Input Overvoltage Alarm is triggered
overtemperatureAlarmTrap .1.3.6.1.4.1.39145.12.0.103
Trap generated when the Overtemperature Alarm is triggered
outputFaultAlarmTrap .1.3.6.1.4.1.39145.12.0.104
Trap generated when the Inverter Output Fault Alarm is triggered
systemFaultAlarmTrap .1.3.6.1.4.1.39145.12.0.105
Trap generated when the System Fault Alarm is triggered
remoteSwitchAlarmTrap .1.3.6.1.4.1.39145.12.0.106
Trap generated when the Remote Switch accessory is activated
undervoltageAlarmClear .1.3.6.1.4.1.39145.12.0.111
Trap generated when the Battery Input Undervoltage Alarm is cleared
overvoltageAlarmClear .1.3.6.1.4.1.39145.12.0.112
Trap generated when the Battery Input Overvoltage Alarm is cleared
overtemperatureAlarmClear .1.3.6.1.4.1.39145.12.0.113
Trap generated when the Overtemperature Alarm is cleared
outputFaultAlarmClear .1.3.6.1.4.1.39145.12.0.114
Trap generated when the Inverter Output Fault Alarm is cleared
systemFaultAlarmClear .1.3.6.1.4.1.39145.12.0.115
Trap generated when the System Fault Alarm is cleared
remoteSwitchAlarmClear .1.3.6.1.4.1.39145.12.0.116
Trap generated when the Remote Switch accessory is deactivated
inverterPowerTrap .1.3.6.1.4.1.39145.12.0.121
Trap generated when the Output switches to Inverter (Battery) Power
gridPowerTrap .1.3.6.1.4.1.39145.12.0.122
Trap generated when the Output switches to Grid Power