HUAWEI-VO-DIGITAL-IF-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
111
.1.3.6.1.4.1.2011.5.25.1.4.1.1 · 1 row entry · 5 columns
The voice digital interface common configuration table contains information
about configuration parameters for digital voice interface.
hwVoDigitalIfCommonCfgEntry entry .1.3.6.1.4.1.2011.5.25.1.4.1.1.1
An entry in the voice digital interface common configuration table.
The entry is automatically created when a digital voice interface hardware is found.
Indexes
hwVoDigitalIfCfgPortNumber hwVoDigitalIfCfgGroupNumber
Column Syntax OID
hwVoDigitalIfCfgPortNumber
Index of voice digital interface common config table. It identify the
number of the voice port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.5.25.1.4.1.1.1.1
hwVoDigitalIfCfgGroupNumber
Index of voice digital interface common config table. It identify the
number of the ds0 or pri group.
Integer32
Constraints:
range: 0-30
.1.3.6.1.4.1.2011.5.25.1.4.1.1.1.2
hwVoDigitalIfCfgBoardType
This object expresses the type of digital voice interface.
Enumeration
Enumerated Values:
1e1vi
2t1vi
.1.3.6.1.4.1.2011.5.25.1.4.1.1.1.3
hwVoDigitalIfCfgSignalType
This object expresses the signal type of ds0 or pri group.
Enumeration
Enumerated Values:
1r2
2dss1
3em
.1.3.6.1.4.1.2011.5.25.1.4.1.1.1.4
hwVoDigitalIfCfgTimeSlotsConfigurable
This object expresses whether the timeslot is available.
'1' states the timeslot is available for the E1VI or T1VI,
'0' states the timeslot is not available. For T1VI, the
length is 24. For E1VI, the length is 32.
OctetString
Constraints:
range: 32-32
range: 24-24
.1.3.6.1.4.1.2011.5.25.1.4.1.1.1.5
.1.3.6.1.4.1.2011.5.25.1.4.2.1 · 1 row entry · 5 columns
The voice digital interface e&m configuration table contains information
about configuration parameters for digital e&m voice interface.
hwVoDigitalIfEMCfgEntry entry .1.3.6.1.4.1.2011.5.25.1.4.2.1.1
An entry in the voice digital interface e&m configuration table.
The entry is automatically created when a digital voice interface is
configed for digital e&m signal.
Indexes
hwVoDigitalIfEMCfgPortNumber hwVoDigitalIfEMCfgGroupNumber
Column Syntax OID
hwVoDigitalIfEMCfgPortNumber
Index of voice digital interface e&m config table. It identify the
number of the voice port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.5.25.1.4.2.1.1.1
hwVoDigitalIfEMCfgGroupNumber
Index of voice digital interface e&m config table. It identify the
number of the ds0 group.
Integer32
Constraints:
range: 0-30
.1.3.6.1.4.1.2011.5.25.1.4.2.1.1.2
hwVoDigitalIfEMCfgTimeoutInterDigits
This object states the longest time to wait between two input digit from
caller side. The default value is 10 seconds.
Integer32r/w
Constraints:
range: 0-120
.1.3.6.1.4.1.2011.5.25.1.4.2.1.1.3
hwVoDigitalIfEMCfgTimeoutRinging
This object expresses the ring timeout of the digital e&m interface.
The value of 65535 indicates the timer is approach infinity. The
default value of this object is 60 seconds.
Integer32r/w
Constraints:
range: 65535-65535
range: 5-600
.1.3.6.1.4.1.2011.5.25.1.4.2.1.1.4
hwVoDigitalIfEMCfgTimeoutWaitDigit
This object expresses the wait digit timeout of the digital e&m interface.
The value of 65535 indicates the timer is approach infinity. The
default value of this object is 5 seconds.
Integer32r/w
Constraints:
range: 65535-65535
range: 3-600
.1.3.6.1.4.1.2011.5.25.1.4.2.1.1.5
.1.3.6.1.4.1.2011.5.25.1.4.2.2 · 1 row entry · 6 columns
The voice digital interface e&m abcd configuration table contains information
about abcd bits configuration parameters for digital e&m voice interface.
hwVoDigitalIfEMABCDCfgEntry entry .1.3.6.1.4.1.2011.5.25.1.4.2.2.1
An entry in the voice digital interface e&m abcd configuration table.
The entry is automatically created when a digital voice interface is
configed for digital e&m signal.
Indexes
hwVoDigitalIfEMABCDCfgPortNumber hwVoDigitalIfEMABCDCfgGroupNumber
Column Syntax OID
hwVoDigitalIfEMABCDCfgPortNumber
Index of voice digital interface e&m abcd config table. It identify the
number of the voice port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.5.25.1.4.2.2.1.1
hwVoDigitalIfEMABCDCfgGroupNumber
Index of voice digital interface e&m abcd config table. It identify the
number of the ds0 group.
Integer32
Constraints:
range: 0-30
.1.3.6.1.4.1.2011.5.25.1.4.2.2.1.2
hwVoDigitalIfEMABCDRxIdle
This object expresses the a b c d bits for receiving idle signal.
The default value is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.2.2.1.3
hwVoDigitalIfEMABCDRxSeize
This object expresses the a b c d bits for receiving seize signal.
The default value is '0101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.2.2.1.4
hwVoDigitalIfEMABCDTxIdle
This object expresses the a b c d bits for sending idle signal.
The default value is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.2.2.1.5
hwVoDigitalIfEMABCDTxSeize
This object expresses the a b c d bits for sending seize signal.
The default value is '0101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.2.2.1.6
.1.3.6.1.4.1.2011.5.25.1.4.2.4 · 1 row entry · 11 columns
The voice digital interface e&m timer table contains information
about timer parameters for digital e&m voice interface.
hwVoDigitalIfEMTimerEntry entry .1.3.6.1.4.1.2011.5.25.1.4.2.4.1
An entry in the voice digital interface e&m timer table.
The entry is automatically created when a digital voice interface is
configed for digital e&m signal.
Indexes
hwVoDigitalIfEMTimerPortNumber hwVoDigitalIfEMTimerGroupNumber
Column Syntax OID
hwVoDigitalIfEMTimerPortNumber
Index of voice digital interface e&m timer config table. It identify the
number of the voice port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.1
hwVoDigitalIfEMTimerGroupNumber
Index of voice digital interface e&m timer config table. It identify the
number of the ds0 group.
Integer32
Constraints:
range: 0-30
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.2
hwVoDigitalIfEMTimerCallInterval
This object expresses the dureation of call clearing. The default value
is 200 milliseconds.
Integer32r/w
Constraints:
range: 200-2000
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.3
hwVoDigitalIfEMTimerSendWink
This object expresses the max time between receiving seizure signal
and sending wink signal. The default value is 500 milliseconds.
Integer32r/w
Constraints:
range: 100-5000
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.4
hwVoDigitalIfEMTimerWinkRising
This object expresses the max time between sending seizure signal and
receiving wink signal. The default value is 1000 milliseconds.
Integer32r/w
Constraints:
range: 100-5000
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.5
hwVoDigitalIfEMTimerWinkHold
This object expresses the max duration for sending wink signal.
The default value is 500 milliseconds.
Integer32r/w
Constraints:
range: 100-3000
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.6
hwVoDigitalIfEMTimerDialoutDelay
This object expresses max time sending called digits. The
default value is 300 milliseconds.
Integer32r/w
Constraints:
range: 50-5000
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.7
hwVoDigitalIfEMTimerRising
This object expresses the wait duration between receiveing seizure
signal and sending delay signal. The default value is 300 milliseconds.
Integer32r/w
Constraints:
range: 20-2000
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.8
hwVoDigitalIfEMTimerHold
This object expresses the max time sending delay signal.
The default value is 400 milliseconds.
Integer32r/w
Constraints:
range: 100-5000
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.9
hwVoDigitalIfEMTimerDtmf
This object expresses outgoing dtmf digit duration of the digital
e&m interface. The default value is 120 milliseconds
Integer32r/w
Constraints:
range: 50-500
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.10
hwVoDigitalIfEMTimerDtmfInterval
This object expresses outgoing dtmf inter-digit duration of the digital
e&m interface. The default value is 120 milliseconds
Integer32r/w
Constraints:
range: 50-500
.1.3.6.1.4.1.2011.5.25.1.4.2.4.1.11
.1.3.6.1.4.1.2011.5.25.1.4.3.1 · 1 row entry · 64 columns
The voice digital interface r2 configuration table contains information
about configuration parameters for digital r2 voice interface.
hwVoDigitalIfR2CfgEntry entry .1.3.6.1.4.1.2011.5.25.1.4.3.1.1
An entry in the voice digital interface r2 configuration table.
The entry is automatically created when a digital voice interface is
configed for digital r2 signal.
Indexes
hwVoDigitalIfR2CfgPortNumber hwVoDigitalIfR2CfgGroupNumber
Column Syntax OID
hwVoDigitalIfR2CfgPortNumber
Index of voice digital interface r2 config table. It identify the
number of the voice port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.1
hwVoDigitalIfR2CfgGroupNumber
Index of voice digital interface r2 config table. It identify the
number of the ds0 group.
Integer32
Constraints:
range: 0-30
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.2
hwVoDigitalIfR2CfgAniSwitch deprecated
This object expresses the ANI funtion is enable or disable.
The default value is disable.
Enumeration
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.3
hwVoDigitalIfR2CallerDigits deprecated
This object expresses how many digits will be collected befor sending A6.
The default value of this object is 1.
Integer32r/w
Constraints:
range: 1-10
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.4
hwVoDigitalIfR2DebounceTime deprecated
This object expresses the minimus duration the line signal to persist.
The default value of this object is 40.
Integer32r/w
Constraints:
range: 10-40
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.5
hwVoDigitalIfR2Ka deprecated
This object expresses the code of KA signal.
The default value is 1.
Integer32r/w
Constraints:
range: 1-15
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.6
hwVoDigitalIfR2Kd deprecated
This object expresses the code of KD signal.
The default value is 3.
Integer32r/w
Constraints:
range: 1-15
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.7
hwVoDigitalIfR2SeizureAckTime deprecated
This object expresses the longgest time to wait the seizure
acknowldge signal. The default value is 1000 milliseconds.
Integer32r/w
Constraints:
range: 200-3000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.8
hwVoDigitalIfR2SelectMode deprecated
This object expresses the trunk mode to be selected.
max set select trunk mode to max-mode
maxpoll set select trunk mode to max-poll-mode
min set select trunk mode to min-mode
minpoll …
Enumerationr/w
Enumerated Values:
1max
2maxpoll
3min
4minpoll
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.9
hwVoDigitalIfR2TimeoutKb deprecated
This object expresses the maxinum time to wait kb signal.
The default value of this object is 5000 milliseconds.
Integer32r/w
Constraints:
range: 1000-50000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.10
hwVoDigitalIfR2TimeoutKd deprecated
This object expresses the maxinum time to wait kd signal.
The default value of this object is 5000 milliseconds.
Integer32r/w
Constraints:
range: 1000-50000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.11
hwVoDigitalIfR2TimeoutNextNumber deprecated
This object expresses the maxinum time to wait next number.
The default value of this object is 5000 milliseconds.
Integer32r/w
Constraints:
range: 1000-50000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.12
hwVoDigitalIfR2TimeoutReleaseApprove deprecated
This object expresses the maxinum time to wait release approve.
The default value of this object is 1000 milliseconds.
Integer32r/w
Constraints:
range: 200-3000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.13
hwVoDigitalIfR2TimeoutRing deprecated
This object expresses the maxinum time to wait the end of ring.
The default value is 30000 milliseconds.
Integer32r/w
Constraints:
range: 1000-240000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.14
hwVoDigitalIfR2TimeoutSendAnswer deprecated
This object expresses the maxinum time to wait Answer signal.
The default value is 500 milliseconds.
Integer32r/w
Constraints:
range: 50-1000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.15
hwVoDigitalIfR2CfgBillingCategory
This object expresses the value of signal BillingCategory.
The default value is 2.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.16
hwVoDigitalIfR2CfgCallingCategory
This object expresses the value of signal CallingCategory.
The default value is 1.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.17
hwVoDigitalIfR2CfgCongestion
This object expresses the value of signal Congestion.
The default value is 4.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.18
hwVoDigitalIfR2CfgDemandRefused
This object expresses the value of signal DemandRefused.
The default value is 12.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.19
hwVoDigitalIfR2CfgDigitEnd
This object expresses the value of signal DigitEnd.
The default value is 15.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.20
hwVoDigitalIfR2CfgNullnum
This object expresses the value of signal Nullnum.
The default value is 5.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.21
hwVoDigitalIfR2CfgReqBillingCategory
This object expresses the value of signal requesting BillingCategory.
The default value is 16.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.22
hwVoDigitalIfR2CfgReqCallingCategory
This object expresses the value of signal requesting CallingCategory.
The default value is 5.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.23
hwVoDigitalIfR2CfgReqCurrentdigit
This object expresses the value of signal requesting Currentdigit.
The default value is 16.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.24
hwVoDigitalIfR2CfgReqFirstCallingnum
This object expresses the value of signal requesting FirstCallingnum.
The default value is 5.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.25
hwVoDigitalIfR2CfgReqFirstDigit
This object expresses the value of signal requesting FirstDigit.
The default value is 16.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.26
hwVoDigitalIfR2CfgReqNextCallednum
This object expresses the value of signal requesting NextCallednum.
The default value is 1.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.27
hwVoDigitalIfR2CfgReqNextCallingnum
This object expresses the value of signal requesting NextCallingnum.
The default value is 5.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.28
hwVoDigitalIfR2CfgReqLastFirstDigit
This object expresses the value of signal requesting LastFirstDigit.
The default value is 2.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.29
hwVoDigitalIfR2CfgReqLastSecondDigit
This object expresses the value of signal requesting LastSecondDigit.
The default value is 7.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.30
hwVoDigitalIfR2CfgReqLastThirdDigit
This object expresses the value of signal requesting LastFirstDigit.
The default value is 8.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.31
hwVoDigitalIfR2CfgReqSwitchGroupB
This object expresses the value of signal requesting SwitchGroupB.
The default value is 3.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.32
hwVoDigitalIfR2CfgSubscriberIdle
This object expresses the value of signal SubscriberIdle.
The default value is 6.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.33
hwVoDigitalIfR2CfgSubscriberBusy
This object expresses the value of signal SubscriberBusy.
The default value is 3.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.34
hwVoDigitalIfR2CfgDebounceTime
This object expresses the minimus duration the line signal to persist.
The default value of this object is 10.
Integer32r/w
Constraints:
range: 10-40
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.35
hwVoDigitalIfR2CfgSendringBackTime
This object expresses the minimus duration the back-ring to persist.
The default value of this object is 60000.
Integer32r/w
Constraints:
range: 1000-90000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.36
hwVoDigitalIfR2CfgSendringBusyTime
This object expresses the minimus duration the busy-ring to persist.
The default value of this object is 30000.
Integer32r/w
Constraints:
range: 1000-90000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.37
hwVoDigitalIfR2CfgPulseSignalPersistenceTime
This object expresses the value of PulseSignalPersistence-Timer.
The default value is 150.
Integer32r/w
Constraints:
range: 50-3000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.38
hwVoDigitalIfR2CfgDlAnswerTime
This object expresses the value of Answer-Timer.
The default value is 60000.
Integer32r/w
Constraints:
range: 100-120000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.39
hwVoDigitalIfR2CfgDlClearBackTime
This object expresses the value of ClearBack-Timer.
The default value is 1000.
Integer32r/w
Constraints:
range: 100-60000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.40
hwVoDigitalIfR2CfgDlClearForwardTime
This object expresses the value of ClearForward-Timer.
The default value is 1000.
Integer32r/w
Constraints:
range: 100-60000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.41
hwVoDigitalIfR2CfgDlSeizureTime
This object expresses the value of Seize-Timer.
The default value is 1000.
Integer32r/w
Constraints:
range: 100-5000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.42
hwVoDigitalIfR2CfgDlReanswerTime
This object expresses the value of ReAnswer-Timer.
The default value is 1000.
Integer32r/w
Constraints:
range: 100-60000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.43
hwVoDigitalIfR2CfgDlReleaseGuardTime
This object expresses the value of ReleaseGuard-Timer.
The default value is 1000.
Integer32r/w
Constraints:
range: 100-60000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.44
hwVoDigitalIfR2CfgMfcGroupBTime
This object expresses the value of GroupB-Timer.
The default value is 30000.
Integer32r/w
Constraints:
range: 100-90000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.45
hwVoDigitalIfR2CfgAniEnable
This object expresses the ANI is enable or disable.
The default value is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.46
hwVoDigitalIfR2CfgGroupBEnable
This object expresses the GroupB-Process is enable or disable .
The default value is enable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.47
hwVoDigitalIfR2CfgClearForwardAckEnable
This object expresses the ClearForwardAck-Signal is enable or disable .
The default value is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.48
hwVoDigitalIfR2CfgDlSeizureAckEnable
This object expresses the SeizureAck-Signal is enable or disable .
The default value is enable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.49
hwVoDigitalIfR2CfgDTMFEnable
This object expresses the DTMF is enable or disable .
The default value is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.50
hwVoDigitalIfR2CfgAnswerEnable
This object expresses the Answer-Signal is enable or disable .
The default value is enable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.51
hwVoDigitalIfR2CfgReanswerEnable
This object expresses the ReAnswer-Signal is enable or disable .
The default value is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.52
hwVoDigitalIfR2CfgFinalCallnumEnable
This object expresses the FinalCallnum-Signal is enable or disable .
The default value is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.53
hwVoDigitalIfR2CfgForceMeteringEnable
This object expresses the Metering-Signal is enable or disable .
The default value is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.54
hwVoDigitalIfR2CfgSendRingBackEnable
This object expresses the SendRingBack is enable or disable .
The default value is enable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.55
hwVoDigitalIfR2CfgSendRingBusyEnable
This object expresses the SendRingBusy is enable or disable .
The default value is enable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.56
hwVoDigitalIfR2CfgReqCategoryOffset
This object expresses the value of CategoryOffset .
The default value is 1.
Integer32r/w
Constraints:
range: 1-10
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.57
hwVoDigitalIfR2CfgReqCallingnumOffset
This object expresses the value of CallingnumOffset .
The default value is 1.
Integer32r/w
Constraints:
range: 1-10
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.58
hwVoDigitalIfR2CfgCountryMode
This object expresses the value of CountryMode .
The default value is 9.
Enumerationr/w
Enumerated Values:
0argentina
1australia
2bengal
3brazil
4china
5customer
6hongkong
7india
8indonesia
9itu-t
10korea
11malaysia
12mexico
13newzealand
14singapore
15thailand
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.59
hwVoDigitalIfR2CfgSpecialCharacter
This object expresses the SpecialCharacter(A,B,C,D,#,*).
The default value is NULL.
Enumerationr/w
Enumerated Values:
0null
35pound
42asterisk
65a
66b
67c
68d
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.60
hwVoDigitalIfR2CfgSpecialSignal
This object expresses the signal of SpecialCharacter.
The default value is 16.
Integer32r/w
Constraints:
range: 11-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.61
hwVoDigitalIfR2CfgSelectMode
This object expresses the trunk mode to be selected.
max set select trunk mode to max-mode
maxpoll set select trunk mode to max-poll-mode
min set select trunk mode to min-mode
minpoll …
Enumerationr/w
Enumerated Values:
1min
2max
3minpoll
4maxpoll
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.62
hwVoDigitalIfR2CfgDTMFTime
This object expresses the value of DTMF-Timer.
The default value is 0.
Integer32r/w
Constraints:
range: 0-10000
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.63
hwVoDigitalIfR2CfgReqCallCreate
This object expresses the value of signal callcreate in group-a.
The default value is 6.
Integer32r/w
Constraints:
range: 1-16
.1.3.6.1.4.1.2011.5.25.1.4.3.1.1.64
.1.3.6.1.4.1.2011.5.25.1.4.3.2 · 1 row entry · 20 columns
The voice digital interface r2 abcd configuration table contains information
about abcd bits configuration parameters for digital r2 voice interface.
hwVoDigitalIfR2ABCDCfgEntry entry .1.3.6.1.4.1.2011.5.25.1.4.3.2.1
An entry in the voice digital interface r2 abcd configuration table.
The entry is automatically created when a digital voice interface is
configed for digital r2 signal.
Indexes
hwVoDigitalIfR2ABCDCfgPortNumber hwVoDigitalIfR2ABCDCfgGroupNumber
Column Syntax OID
hwVoDigitalIfR2ABCDCfgPortNumber
Index of voice digital interface r2 abcd config table. It identify the
number of the voice port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.1
hwVoDigitalIfR2ABCDCfgGroupNumber
Index of voice digital interface r2 abcd config table. It identify the
number of the ds0 group.
Integer32
Constraints:
range: 0-30
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.2
hwVoDigitalIfR2ABCDReverseABCD
This object expresses whether or not the a b c d bits should be invert.
'0' : disable invert.
'1' : enable invert.
The default value is '0000'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.3
hwVoDigitalIfR2ABCDRenewABCD
This object expresses the unused a b c d bits to be sent. The default value
is '1111'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.4
hwVoDigitalIfR2ABCDRxIdle
This object expresses the idle line signal bits to be received. The default value
is '1001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.5
hwVoDigitalIfR2ABCDTxIdle
This object expresses the idle line signal bits to be sent. The default value
is '1001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.6
hwVoDigitalIfR2ABCDRxSeizure
This object expresses the seizure line signal bits to be received. The default value
is '0001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.7
hwVoDigitalIfR2ABCDTxSeizure
This object expresses the seizure line signal bits to be sent. The default value
is '0001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.8
hwVoDigitalIfR2ABCDRxSeizureAck
This object expresses the seizureAck line signal bits to be received. The default value
is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.9
hwVoDigitalIfR2ABCDTxSeizureAck
This object expresses the seizureAck line signal bits to be sent. The default value
is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.10
hwVoDigitalIfR2ABCDRxAnswer
This object expresses the answer line signal bits to be received. The default value
is '0101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.11
hwVoDigitalIfR2ABCDTxAnswer
This object expresses the answer line signal bits to be sent. The default value
is '0101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.12
hwVoDigitalIfR2ABCDRxClearForward
This object expresses the ClearForward line signal bits to be received. The default value
is '1001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.13
hwVoDigitalIfR2ABCDTxClearForward
This object expresses the ClearForward line signal bits to be sent. The default value
is '1001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.14
hwVoDigitalIfR2ABCDRxClearBack
This object expresses the ClearBackward line signal bits to be received. The default value
is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.15
hwVoDigitalIfR2ABCDTxClearBack
This object expresses the ClearBackward line signal bits to be sent. The default value
is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.16
hwVoDigitalIfR2ABCDRxReleaseGuard
This object expresses the ReleaseGuard line signal bits to be received. The default value
is '1001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.17
hwVoDigitalIfR2ABCDTxReleaseGuard
This object expresses the ReleaseGuard line signal bits to be sent. The default value
is '1001'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.18
hwVoDigitalIfR2ABCDRxBlocking
This object expresses the Blocking line signal bits to be received. The default value
is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.19
hwVoDigitalIfR2ABCDTxBlocking
This object expresses the Blocking line signal bits to be sent. The default value
is '1101'.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.2011.5.25.1.4.3.2.1.20