HPN-ICF-TRANSCEIVER-INFO-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
43
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1 · 1 row entry · 38 columns
This table show the information of transceiver on interface.
hpnicfTransceiverInfoEntry entry .1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1
The entry of the hpnicfTransceiverInfoTable.
Indexes
IF-MIBifIndex
Column Syntax OID
hpnicfTransceiverHardwareType
Hardware type of the interface, such as SM(single mode).
OctetString .1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.1
hpnicfTransceiverType
Type of the interface, such as SFP/XFP/GBIC.
OctetString .1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.2
hpnicfTransceiverWaveLength
Wave length of the interface, measured in nanometer.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.3
hpnicfTransceiverVendorName
Vendor name of the interface.
OctetString .1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.4
hpnicfTransceiverSerialNumber
Serial number of the interface.
OctetString .1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.5
hpnicfTransceiverFiberDiameterType
The diameter of the fiber, measured in micron.
fiber9 - 9 micron multi-mode fiber
fiber50 - 50 micron multi-mode fiber
fiber625 - 62.5 micron multi-mode fiber
copper - copper cable.
Enumeration
Enumerated Values:
1fiber9
2fiber50
3fiber625
4copper
65535unknown
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.6
hpnicfTransceiverTransferDistance
The maximal distance which the interface could transmit,
measured in meter.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.7
hpnicfTransceiverDiagnostic
Indicating the digital diagnostic monitoring function .
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.8
hpnicfTransceiverCurTXPower
Indicating the current transmitted power .
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.9
hpnicfTransceiverMaxTXPower
Indicating the maximal transmitted power .
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.10
hpnicfTransceiverMinTXPower
Indicating the minimal transmitted power .
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.11
hpnicfTransceiverCurRXPower
Indicating the current received power .
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.12
hpnicfTransceiverMaxRXPower
Indicating the maximal received power .
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.13
hpnicfTransceiverMinRXPower
Indicating the minimal received power .
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.14
hpnicfTransceiverTemperature
Indicating the current temperature.
The unit is Celsius centigrade.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.15
hpnicfTransceiverVoltage
Indicating the current voltage .
The unit is in hundredths of V
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.16
hpnicfTransceiverBiasCurrent
Indicating the current bias electric current .
The unit is in hundredths of mA
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.17
hpnicfTransceiverTempHiAlarm
Transceiver temperature high alarm threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.18
hpnicfTransceiverTempLoAlarm
Transceiver temperature low alarm threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.19
hpnicfTransceiverTempHiWarn
Transceiver temperature high warning threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.20
hpnicfTransceiverTempLoWarn
Transceiver temperature low warning threshold
limit in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.21
hpnicfTransceiverVccHiAlarm
Transceiver VCC high alarm threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.22
hpnicfTransceiverVccLoAlarm
Transceiver VCC low alarm threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.23
hpnicfTransceiverVccHiWarn
Transceiver VCC high warning threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.24
hpnicfTransceiverVccLoWarn
Transceiver VCC low warning threshold
limit in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.25
hpnicfTransceiverBiasHiAlarm
Transceiver bias high alarm threshold limit in microamps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.26
hpnicfTransceiverBiasLoAlarm
Transceiver bias low alarm threshold limit in microamps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.27
hpnicfTransceiverBiasHiWarn
Transceiver bias high warning threshold limit in microamps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.28
hpnicfTransceiverBiasLoWarn
Transceiver bias low warning threshold limit in microamps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.29
hpnicfTransceiverPwrOutHiAlarm
Transceiver transmit power high alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.30
hpnicfTransceiverPwrOutLoAlarm
Transceiver transmit power low alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.31
hpnicfTransceiverPwrOutHiWarn
Transceiver transmit power high warning
threshold limit in tenths of microwatts
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.32
hpnicfTransceiverPwrOutLoWarn
Transceiver transmit power low warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.33
hpnicfTransceiverRcvPwrHiAlarm
Transceiver receive power high alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.34
hpnicfTransceiverRcvPwrLoAlarm
Transceiver receive power low alarm
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.35
hpnicfTransceiverRcvPwrHiWarn
Transceiver receive power high warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.36
hpnicfTransceiverRcvPwrLoWarn
Transceiver receive power low warning
threshold limit in tenths of microwatts.
As an example: 10000 is 1 milliwatt.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.37
hpnicfTransceiverErrors
Bitmask indicating transceiver errors.
Transceiver information I/O error(0)
Transceiver information checksum error(1)
Transceiver type and port configuration mismatch(2)
Transceiver type not supported by port hardware(3…
Bits
Enumerated Values:
0xcvrIOError
1xcvrChecksum
2xcvrTypeAndPortConfigMismatch
3xcvrTypeNotSupported
4wisLocalFault
5rcvOpticalPowerFault
6pmapmdReceiverLocalFault
7pcsReceiveLocalFault
8phyXSReceiveLocalFault
9laserBiasCurrentFault
10laserTemperatureFault
11laserOutputPowerFault
12txFault
13pmapmdTransmitterLocalFault
14pcsTransmitLocalFault
15phyXSTransmitLocalFault
16rxLossOfSignal
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.1.1.38
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.2 · 1 row entry · 5 columns
This table provides statistics about transceiver with multi-channel.
hpnicfTransceiverChannelEntry entry .1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1
The entry of the hpnicfTransceiverChannelTable.
Indexes
IF-MIBifIndex hpnicfTransceiverChannelIndex
Column Syntax OID
hpnicfTransceiverChannelIndex
The channel index of transceiver.
Indicating one channel of the interface.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.1
hpnicfTransceiverChannelCurTXPower
Indicating the current transmission power.
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.2
hpnicfTransceiverChannelCurRXPower
Indicating the current received power.
The unit is in hundredths of dBM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.3
hpnicfTransceiverChannelTemperature
Indicating the current temperature.
The unit is Celsius centigrade.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.4
hpnicfTransceiverChannelBiasCurrent
Indicating the current bias electric current.
The unit is in hundredths of mA.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.14.11.15.2.70.1.2.1.5