hpEnvironment10
|
.1.3.6.1.4.1.11.2.23.45.0.10 |
One of the voltage sensors crossed its upper non-critical threshold.
|
hpSystemHW113
|
.1.3.6.1.4.1.11.2.23.45.0.113 |
A SCSI cable has been removed from the hot swap cage.
|
hpEnvironment12
|
.1.3.6.1.4.1.11.2.23.45.0.12 |
One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage
|
hpChassis26
|
.1.3.6.1.4.1.11.2.23.45.0.26 |
The chassis has been opened.
|
hpTemperature4
|
.1.3.6.1.4.1.11.2.23.45.0.4 |
One of the temperature sensors crossed its upper non-critical threshold.
|
hpTemperature5
|
.1.3.6.1.4.1.11.2.23.45.0.5 |
One of the temperature sensors crossed its upper critical threshold.
|
hpECCMemory518
|
.1.3.6.1.4.1.11.2.23.45.0.518 |
Uncorrectable multi-bit ECC error has occurred in memory module
|
hpTemperature6
|
.1.3.6.1.4.1.11.2.23.45.0.6 |
One of the temperature sensors crossed its upper non-recoverable threshold.
|
hpSystemFW699
|
.1.3.6.1.4.1.11.2.23.45.0.699 |
Machine Check Initiated
|
hpSystemFW700
|
.1.3.6.1.4.1.11.2.23.45.0.700 |
System firmware error
|
hpEnvironment704
|
.1.3.6.1.4.1.11.2.23.45.0.704 |
Voltage fault - Check all boards with this voltage
|
hpEnvironment705
|
.1.3.6.1.4.1.11.2.23.45.0.705 |
Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage
|
hpEnvironment706
|
.1.3.6.1.4.1.11.2.23.45.0.706 |
Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage
|
hpEnvironment707
|
.1.3.6.1.4.1.11.2.23.45.0.707 |
Voltage absent
|
hpFan710
|
.1.3.6.1.4.1.11.2.23.45.0.710 |
Fan speed lags
|
hpRedundantPower720
|
.1.3.6.1.4.1.11.2.23.45.0.720 |
Power supply failed or disconnected
|
hpRedundantPower722
|
.1.3.6.1.4.1.11.2.23.45.0.722 |
Power supply AC lost
|
hpPowerSupply726
|
.1.3.6.1.4.1.11.2.23.45.0.726 |
A/C Failed, disconnected, or out of range
|
hpEnvironment728
|
.1.3.6.1.4.1.11.2.23.45.0.728 |
Voltage degraded to critical level from less severe - Check all boards with this voltage
|
hpSystemHW729
|
.1.3.6.1.4.1.11.2.23.45.0.729 |
System shut-down or reset caused by sensor reading.
|
hpBmcFirmware730
|
.1.3.6.1.4.1.11.2.23.45.0.730 |
The BMC firmware did not detect the system firmware boot.
|
hpPowerSupply731
|
.1.3.6.1.4.1.11.2.23.45.0.731 |
A/C Failed, disconnected, or out of range
|
hpRedundantPower732
|
.1.3.6.1.4.1.11.2.23.45.0.732 |
The Power supply's sensors detect possible problems
|
hpSystemHW733
|
.1.3.6.1.4.1.11.2.23.45.0.733 |
Cooling unit warning
|
hpSystemHW734
|
.1.3.6.1.4.1.11.2.23.45.0.734 |
Cooling unit failure
|
hpSystemHW735
|
.1.3.6.1.4.1.11.2.23.45.0.735 |
BMC entering special mode
|
hpSystemHW736
|
.1.3.6.1.4.1.11.2.23.45.0.736 |
Watchdog timer expired - hard reset
|
hpSystemHW737
|
.1.3.6.1.4.1.11.2.23.45.0.737 |
Watchdog timer expired - power-off
|
hpSystemHW738
|
.1.3.6.1.4.1.11.2.23.45.0.738 |
Watchdog timer expired - power-cycle
|
hpSystemHW739
|
.1.3.6.1.4.1.11.2.23.45.0.739 |
Missing FRU device
|
hpSystemHW740
|
.1.3.6.1.4.1.11.2.23.45.0.740 |
Missing Entity
|
hpSystemHW744
|
.1.3.6.1.4.1.11.2.23.45.0.744 |
System event log almost full
|
hpSystemHW745
|
.1.3.6.1.4.1.11.2.23.45.0.745 |
TOC interrupt (crash dump)
|
hpSystemHW746
|
.1.3.6.1.4.1.11.2.23.45.0.746 |
INIT Initiated
|
hpSystemHW747
|
.1.3.6.1.4.1.11.2.23.45.0.747 |
PCI system error detected
|
hpSystemHW748
|
.1.3.6.1.4.1.11.2.23.45.0.748 |
OS run-time critical shutdown
|
hpSystemHW749
|
.1.3.6.1.4.1.11.2.23.45.0.749 |
ACPI state S5 (soft-off, entered by override)
|
hpSystemHW751
|
.1.3.6.1.4.1.11.2.23.45.0.751 |
PCI parity error detected
|
hpTempHighWarning752
|
.1.3.6.1.4.1.11.2.23.45.0.752 |
One of the temperature sensors crossed its lower non-critical threshold.
|
hpTempHighCritical753
|
.1.3.6.1.4.1.11.2.23.45.0.753 |
One of the temperature sensors crossed its upper critical threshold.
|
hpTempHighNonRecoverable754
|
.1.3.6.1.4.1.11.2.23.45.0.754 |
One of the temperature sensors crossed its upper non-recoverable threshold.
|
hpTemperature755
|
.1.3.6.1.4.1.11.2.23.45.0.755 |
A temperature inside the server has gone outside the factory specified range.
|
hpTemperature756
|
.1.3.6.1.4.1.11.2.23.45.0.756 |
One of the temperature sensors crossed its upper critical threshold.
|
hpRedundantPower757
|
.1.3.6.1.4.1.11.2.23.45.0.757 |
The Power Supply AC voltage was lost or is out of range.
|
hpRedundantPower758
|
.1.3.6.1.4.1.11.2.23.45.0.758 |
The AC voltage connected to the power supply is out of range.
|
hpEnvironment8
|
.1.3.6.1.4.1.11.2.23.45.0.8 |
One of the voltage sensors crossed its lower critical threshold.
|
hpEnvironment9
|
.1.3.6.1.4.1.11.2.23.45.0.9 |
One of the voltage sensors crossed its lower non-recoverable threshold.
|