HM2-PWRMGMT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
21
.1.3.6.1.4.1.248.11.11.1.1.1 · 1 row entry · 2 columns
This table contains all variables related to the power supply
units of the chassis/switch. For each power supply slot exists
one instance.
hm2PSEntry entry .1.3.6.1.4.1.248.11.11.1.1.1.1
The entry of the hm2PSTable.
Indexes
hm2PSID
Column Syntax OID
hm2PSID
This index is used to identify the associated power supply
unit.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.248.11.11.1.1.1.1.1
hm2PSState
Indicates the operational state of the associated power
supply. If the value of this variable changes, a hm2PowerSupply
trap is sent.
Enumeration
Enumerated Values:
1present
2defective
3notInstalled
4unknown
.1.3.6.1.4.1.248.11.11.1.1.1.1.2
.1.3.6.1.4.1.248.11.11.1.1.10 · 1 row entry · 10 columns
This table contains all EEPROM variables related to the power supply
slot modules of the chassis/switch. For each power supply slot module exists
one instance.
hm2PSUSlotInfoEntry entry .1.3.6.1.4.1.248.11.11.1.1.10.1
The entry of the hm2PSUSlotInfoTable.
Indexes
hm2PSUSlotIndex
Column Syntax OID
hm2PSUSlotIndex
This index is used to identify the associated power supply
slot module.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.248.11.11.1.1.10.1.1
hm2PSUSlotChassisTypeId
The chassis type id of the associated power supply
slot module.
Enumeration
Enumerated Values:
0other
1mach1020
2mach4000
3railswitch
4grs
.1.3.6.1.4.1.248.11.11.1.1.10.1.2
hm2PSUSlotManufacturerId
The manufacturer id of the associated power supply
slot module.
Enumeration
Enumerated Values:
0other
1hirschmann
.1.3.6.1.4.1.248.11.11.1.1.10.1.3
hm2PSUSlotManufacturerDate obsolete
The manufacturer date of the associated power supply
slot module.
*** NOTE this is set to OBSOLETE ***
SNMP-FRAMEWORK-MIBSnmpAdminString
Textual Convention: SNMP-FRAMEWORK-MIBSnmpAdminString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.4
hm2PSUSlotSerialNumber
The serial number of the associated power supply
slot module.
SNMP-FRAMEWORK-MIBSnmpAdminString
Textual Convention: SNMP-FRAMEWORK-MIBSnmpAdminString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.5
hm2PSUSlotProductCode
The product code of the associated power supply
slot module.
SNMP-FRAMEWORK-MIBSnmpAdminString
Textual Convention: SNMP-FRAMEWORK-MIBSnmpAdminString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.6
hm2PSUSlotDescription
The description of the associated power supply
slot module.
SNMP-FRAMEWORK-MIBSnmpAdminString
Textual Convention: SNMP-FRAMEWORK-MIBSnmpAdminString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.7
hm2PSUSlotCombinationType
The combination type of the associated power supply
slot module.
Enumeration
Enumerated Values:
0only-on-psu1
1psu1-sys-psu2-poe
2psu1-poe-psu2-sys
3two-separate-psus
.1.3.6.1.4.1.248.11.11.1.1.10.1.8
hm2PSUSlotTemperatureRange
The temperature range of the associated power supply
slot module.
Enumeration
Enumerated Values:
0tr-0-60
1tr-minus40-60
2tr-minus40-70
3tr-minus40-70cc
4tr-minus40-85
5tr-minus40-85cc
.1.3.6.1.4.1.248.11.11.1.1.10.1.9
hm2PSUSlotRevisionId
Hardware revision of the PSU
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.248.11.11.1.1.10.1.10
.1.3.6.1.4.1.248.11.11.1.1.20 · 1 row entry · 9 columns
This table contains all EEPROM variables related to the power supply
slot module units. For each power supply slot module exists
up to two instances.
hm2PSUUnitInfoEntry entry .1.3.6.1.4.1.248.11.11.1.1.20.1
The entry of the hm2PSUUnitInfoTable.
Indexes
hm2PSUSlotIndex hm2PSUUnitIndex
Column Syntax OID
hm2PSUUnitIndex
The number of PSU units on the associated power supply
slot module.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.248.11.11.1.1.20.1.1
hm2PSUUnitConverterType
The converter type of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
1ac
2dc
.1.3.6.1.4.1.248.11.11.1.1.20.1.2
hm2PSUUnitNumberOfInputs
The number of inputs of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.248.11.11.1.1.20.1.3
hm2PSUUnitOutputType
The output type of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
1system
2both
3poe
.1.3.6.1.4.1.248.11.11.1.1.20.1.4
hm2PSUUnitSystemBudget
The system budget of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.248.11.11.1.1.20.1.5
hm2PSUUnitPoeBudget
The PoE budget of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.248.11.11.1.1.20.1.6
hm2PSUUnitFanCount
The fan count of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.248.11.11.1.1.20.1.7
hm2PSUUnitVoltageRange
The voltage range of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
0vr-18-60vdc
1vr-24-60vdc
2vr-24-48vdc
3vr-60-250vdc-110-240vac
4vr-48-54vdc-poe
.1.3.6.1.4.1.248.11.11.1.1.20.1.8
hm2PSUUnitPowerInterruption
The power interruption value of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.248.11.11.1.1.20.1.9