.1.3.6.1.4.1.28507.62.1.1.1.2 · 1 row entry · 2 columns
list of all Trap receiver
pdu8311TrapIPEntry entry .1.3.6.1.4.1.28507.62.1.1.1.2.1
an entry containing management
informations regarding the list of trap
receivers
Indexes
pdu8311TrapIPIndex
Column Syntax OID
pdu8311TrapIPIndex
A unique value, greater than zero, for each receiver slot.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.28507.62.1.1.1.2.1.1
pdu8311TrapAddr
DNS name or IP address specifying one Trap receiver slot.
A port can optionally be specified: 'name:port' An empty
string disables this slot.
OctetStringr/w
Constraints:
range: 0-99
.1.3.6.1.4.1.28507.62.1.1.1.2.1.2
.1.3.6.1.4.1.28507.62.1.5.1.2 · 1 row entry · 24 columns
All available Channel Interfaces.
pdu8311PowerEntry entry .1.3.6.1.4.1.28507.62.1.5.1.2.1
An entry containing management information
applicable to a particular Power Channel.
Indexes
pdu8311PowerIndex
Column Syntax OID
pdu8311PowerIndex
Index of Power Channel entries
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.28507.62.1.5.1.2.1.1
pdu8311ChanStatus
0 = data not active, 1 = data valid
Integer32
Constraints:
range: 0-1
.1.3.6.1.4.1.28507.62.1.5.1.2.1.2
pdu8311AbsEnergyActive
Absolute Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.3
pdu8311PowerActive
Active Power
WSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.5.1.2.1.4
pdu8311Current
Actual Current on Power Channel.
mASNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.5
pdu8311Voltage
Actual Voltage on Power Channel
VSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.6
pdu8311Frequency
Frequency of Power Channel
0.01 hzSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.7
pdu8311PowerFactor
Power Factor of Channel between
-1.0 and 1.00
0.001SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.5.1.2.1.8
pdu8311Pangle
Phase Angle between Voltage
and L Line Current between
-180.0 and 180.0
0.1 degreeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.5.1.2.1.9
pdu8311PowerApparent
L Line Mean Apparent Power
VASNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.5.1.2.1.10
pdu8311PowerReactive
L Line Mean Reactive Power
VARSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.5.1.2.1.11
pdu8311AbsEnergyReactive
Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.12
pdu8311AbsEnergyActiveResettable
Resettable Absolute Active Energy counter.
Writing '0' resets all resettable counter.
WhSNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.13
pdu8311AbsEnergyReactiveResettable
Resettable Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.14
pdu8311ResetTime
Time in seconds since last Energy
Counter reset.
sSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.15
pdu8311ForwEnergyActive
Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.16
pdu8311ForwEnergyReactive
Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.17
pdu8311ForwEnergyActiveResettable
Resettable Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.18
pdu8311ForwEnergyReactiveResettable
Resettable Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.19
pdu8311RevEnergyActive
Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.20
pdu8311RevEnergyReactive
Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.21
pdu8311RevEnergyActiveResettable
Resettable Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.22
pdu8311RevEnergyReactiveResettable
Resettable Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.23
pdu8311ResidualCurrent
Actual Residual Current on Power Channel.
According Typ A IEC 60755. Only visible on
models that support this feature.
mASNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.62.1.5.1.2.1.24
.1.3.6.1.4.1.28507.62.1.6.1 · 1 row entry · 7 columns
pdu8311SensorEntry entry .1.3.6.1.4.1.28507.62.1.6.1.1
Indexes
pdu8311SensorIndex
Column Syntax OID
pdu8311SensorIndex Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.28507.62.1.6.1.1.1
pdu8311TempSensor
actual temperature
0.1 degree CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.6.1.1.2
pdu8311HygroSensor
actual humidity
0.1 percent humiditySNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.6.1.1.3
pdu8311InputSensor
logical state of input sensor
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.28507.62.1.6.1.1.4
pdu8311AirPressure
actual air pressure
1 hPA (hectopascal) ~ 1 milibarSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.6.1.1.5
pdu8311DewPoint
dew point for actual temperature and humidity
0.1 degree CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.6.1.1.6
pdu8311DewPointDiff
difference between dew point and actual
temperature (Temp - DewPoint)
0.1 degree CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.62.1.6.1.1.7