GUDEADS-EPC8316-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
62
.1.3.6.1.4.1.28507.64.1.1.1.2 · 1 row entry · 2 columns
list of all Trap receiver
epc8316TrapIPEntry entry .1.3.6.1.4.1.28507.64.1.1.1.2.1
an entry containing management
informations regarding the list of trap
receivers
Indexes
epc8316TrapIPIndex
Column Syntax OID
epc8316TrapIPIndex
A unique value, greater than zero, for each receiver slot.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.28507.64.1.1.1.2.1.1
epc8316TrapAddr
DNS name or IP address specifying one Trap receiver slot.
A port can optionally be specified: 'name:port' An empty
string disables this slot.
OctetStringr/w
Constraints:
range: 0-99
.1.3.6.1.4.1.28507.64.1.1.1.2.1.2
.1.3.6.1.4.1.28507.64.1.3.1.2 · 1 row entry · 7 columns
list of all EPC Relay Ports
epc8316portEntry entry .1.3.6.1.4.1.28507.64.1.3.1.2.1
An entry containing management information applicable to a
particular relay port.
Indexes
epc8316PortIndex
Column Syntax OID
epc8316PortIndex
A unique value, greater than zero, for each Relay Port.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.28507.64.1.3.1.2.1.1
epc8316PortName
A textual string containing name of a Relay Port.
OctetStringr/w
Constraints:
range: 0-15
.1.3.6.1.4.1.28507.64.1.3.1.2.1.2
epc8316PortState
current state a Relay Port
Enumerationr/w
Enumerated Values:
0off
1on
.1.3.6.1.4.1.28507.64.1.3.1.2.1.3
epc8316PortSwitchCount
The total number of switch actions ocurred on a Relay Port.
Does not count switch commands which will not switch
the ralay state, so just real relay switches are displayed here.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.3.1.2.1.4
epc8316PortStartupMode
set Mode of startup sequence (off, on , remember last state)
Enumerationr/w
Enumerated Values:
0off
1on
2laststate
.1.3.6.1.4.1.28507.64.1.3.1.2.1.5
epc8316PortStartupDelay
Delay in sec for startup action
secondsSNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.3.1.2.1.6
epc8316PortRepowerTime
Delay in sec for repower port after switching off
secondsInteger32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.28507.64.1.3.1.2.1.7
.1.3.6.1.4.1.28507.64.1.5.1.2 · 1 row entry · 23 columns
All available Channel Interfaces.
epc8316PowerEntry entry .1.3.6.1.4.1.28507.64.1.5.1.2.1
An entry containing management information
applicable to a particular Power Channel.
Indexes
epc8316PowerIndex
Column Syntax OID
epc8316PowerIndex
Index of Power Channel entries
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.28507.64.1.5.1.2.1.1
epc8316ChanStatus
0 = data not active, 1 = data valid
Integer32
Constraints:
range: 0-1
.1.3.6.1.4.1.28507.64.1.5.1.2.1.2
epc8316AbsEnergyActive
Absolute Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.3
epc8316PowerActive
Active Power
WSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.1.2.1.4
epc8316Current
Actual Curent on Power Channel.
mASNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.5
epc8316Voltage
Actual Voltage on Power Channel
VSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.6
epc8316Frequency
Frequency of Power Channel
0.01 hzSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.7
epc8316PowerFactor
Power Factor of Channel between
-1.0 and 1.00
0.001SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.1.2.1.8
epc8316Pangle
Phase Angle between Voltage
and L Line Current between
-180.0 and 180.0
0.1 degreeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.1.2.1.9
epc8316PowerApparent
L Line Mean Apparent Power
VASNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.1.2.1.10
epc8316PowerReactive
L Line Mean Reactive Power
VARSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.1.2.1.11
epc8316AbsEnergyReactive
Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.12
epc8316AbsEnergyActiveResettable
Resettable Absolute Active Energy counter.
Writing '0' resets all resettable counter.
WhSNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.13
epc8316AbsEnergyReactiveResettable
Resettable Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.14
epc8316ResetTime
Time in seconds since last Energy
Counter reset.
sSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.15
epc8316ForwEnergyActive
Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.16
epc8316ForwEnergyReactive
Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.17
epc8316ForwEnergyActiveResettable
Resettable Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.18
epc8316ForwEnergyReactiveResettable
Resettable Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.19
epc8316RevEnergyActive
Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.20
epc8316RevEnergyReactive
Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.21
epc8316RevEnergyActiveResettable
Resettable Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.22
epc8316RevEnergyReactiveResettable
Resettable Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.1.2.1.23
.1.3.6.1.4.1.28507.64.1.5.5.2 · 1 row entry · 23 columns
All available Single Port Power Channel Interfaces.
Indices 0-5 mean Ports A1 to A6, 6-11 are Ports B1 to B6.
This table may not be present on devices that have no
measurement on every port.
epc8316spPowerEntry entry .1.3.6.1.4.1.28507.64.1.5.5.2.1
An entry containing management information applicable
to a particular Single Port Power Channel.
Indexes
epc8316spPowerIndex
Column Syntax OID
epc8316spPowerIndex
Index of Single Port Power Channel entries.
Indices 0-5 mean Ports A1 to A6, 6-11 are Ports B1 to B6.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.28507.64.1.5.5.2.1.1
epc8316spChanStatus
0 = data not active, 1 = data valid
Integer32
Constraints:
range: 0-1
.1.3.6.1.4.1.28507.64.1.5.5.2.1.2
epc8316spAbsEnergyActive
Absolute Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.3
epc8316spPowerActive
Active Power
WSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.5.2.1.4
epc8316spCurrent
Actual Curent on Power Channel.
mASNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.5
epc8316spVoltage
Actual Voltage on Power Channel
VSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.6
epc8316spFrequency
Frequency of Power Channel
0.01 hzSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.7
epc8316spPowerFactor
Power Factor of Channel between
-1.0 and 1.00
0.001SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.5.2.1.8
epc8316spPangle
Phase Angle between Voltage
and L Line Current between
-180.0 and 180.0
0.1 degreeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.5.2.1.9
epc8316spPowerApparent
L Line Mean Apparent Power
VASNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.5.2.1.10
epc8316spPowerReactive
L Line Mean Reactive Power
VARSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.5.5.2.1.11
epc8316spAbsEnergyReactive
Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.12
epc8316spAbsEnergyActiveResettable
Resettable Absolute Active Energy counter.
Writing '0' resets all resettable counter.
WhSNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.13
epc8316spAbsEnergyReactiveResettable
Resettable Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.14
epc8316spResetTime
Time in seconds since last Energy
Counter reset.
sSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.15
epc8316spForwEnergyActive
Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.16
epc8316spForwEnergyReactive
Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.17
epc8316spForwEnergyActiveResettable
Resettable Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.18
epc8316spForwEnergyReactiveResettable
Resettable Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.19
epc8316spRevEnergyActive
Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.20
epc8316spRevEnergyReactive
Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.21
epc8316spRevEnergyActiveResettable
Resettable Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.22
epc8316spRevEnergyReactiveResettable
Resettable Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.64.1.5.5.2.1.23
.1.3.6.1.4.1.28507.64.1.6.1 · 1 row entry · 7 columns
epc8316SensorEntry entry .1.3.6.1.4.1.28507.64.1.6.1.1
Indexes
epc8316SensorIndex
Column Syntax OID
epc8316SensorIndex Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.28507.64.1.6.1.1.1
epc8316TempSensor
actual temperature, a value of -9999 indicates
that data is not available
0.1 degree CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.6.1.1.2
epc8316HygroSensor
actual humidity
0.1 percent humiditySNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.6.1.1.3
epc8316InputSensor
logical state of input sensor
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.28507.64.1.6.1.1.4
epc8316AirPressure
actual air pressure
1 hPA (hectopascal) ~ 1 milibarSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.6.1.1.5
epc8316DewPoint
dew point for actual temperature and humidity
0.1 degree CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.6.1.1.6
epc8316DewPointDiff
difference between dew point and actual
temperature (Temp - DewPoint)
0.1 degree CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.64.1.6.1.1.7