FORTINET-FORTIMAIL-MIB
Add fmlMailQueueStatistics listing mail queues and
number of emails and size of emails in queues
fnFortiMailMib
1.3.6.1.4.1.12356.105
Imported Objects
| FORTINET-CORE-MIB | FnBoolState FnIndex FnSessionProto fortinet |
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Gauge32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
Type Definitions (6)
| FmlHAEventIdVal | Enumeration |
masterUnitSwitch(1)slaveUnitSwitch(2)unitShutdown(3) |
| FmlHAModeVal | Enumeration |
off(0)master(1)slave(2)configMaster(3)configSlave(4) |
| FmlIpv6Address | OctetString |
range: 16 |
| FmlOpMode | Enumeration |
gateway(1)transparent(2)server(3) |
| FmlRAIDCodeVal | Enumeration |
degradedArray(1)sparesMissing(2)rebuildStarted(3)rebuildFinished(4)fail(5)failSpare(6)spareActive(7) |
| FmlSysEventCodeVal | Enumeration |
systemHalt(1)systemReboot(2)systemReload(3)systemUpgrade(4)guiUpgrade(5)logdiskFormat(6)maildiskFormat(7)avDBUpdateSuccess(8)avDBUpdateNetworkError(9)avDBUpdateFailure(10) |
Objects (56)
|
|
.1.3.6.1.4.1.12356.105 |
|
|
|
.1.3.6.1.4.1.12356.105.0 |
|
|
|
.1.3.6.1.4.1.12356.105.1 |
|
|
|
OctetString | .1.3.6.1.4.1.12356.105.1.1 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.10 |
|
|
.1.3.6.1.4.1.12356.105.1.101 |
|
|
|
Integer32 | .1.3.6.1.4.1.12356.105.1.101.1 |
|
|
Integer32 | .1.3.6.1.4.1.12356.105.1.101.2 |
|
|
.1.3.6.1.4.1.12356.105.1.102 |
|
|
|
.1.3.6.1.4.1.12356.105.1.102.2 |
|
|
|
.1.3.6.1.4.1.12356.105.1.102.2.1 |
|
|
|
FORTINET-CORE-MIBFnIndex | .1.3.6.1.4.1.12356.105.1.102.2.1.1 |
|
|
FORTINET-CORE-MIBFnSessionProto | .1.3.6.1.4.1.12356.105.1.102.2.1.2 |
|
|
SNMPv2-SMIIpAddress | .1.3.6.1.4.1.12356.105.1.102.2.1.3 |
|
|
FmlIpv6Address | .1.3.6.1.4.1.12356.105.1.102.2.1.4 |
|
|
Integer32 | .1.3.6.1.4.1.12356.105.1.102.2.1.5 |
|
|
SNMPv2-SMIIpAddress | .1.3.6.1.4.1.12356.105.1.102.2.1.6 |
|
|
FmlIpv6Address | .1.3.6.1.4.1.12356.105.1.102.2.1.7 |
|
|
Integer32 | .1.3.6.1.4.1.12356.105.1.102.2.1.8 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.102.2.1.9 |
|
|
.1.3.6.1.4.1.12356.105.1.103 |
|
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.103.1 |
|
|
.1.3.6.1.4.1.12356.105.1.103.2 |
|
|
|
.1.3.6.1.4.1.12356.105.1.103.2.1 |
|
|
|
FORTINET-CORE-MIBFnIndex | .1.3.6.1.4.1.12356.105.1.103.2.1.1 |
|
|
SNMPv2-TCDisplayString | .1.3.6.1.4.1.12356.105.1.103.2.1.2 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.103.2.1.3 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.103.2.1.4 |
|
|
FmlSysEventCodeVal | .1.3.6.1.4.1.12356.105.1.11 |
|
|
.1.3.6.1.4.1.12356.105.1.110 |
|
|
|
Integer32 | .1.3.6.1.4.1.12356.105.1.110.1 |
|
|
.1.3.6.1.4.1.12356.105.1.110.2 |
|
|
|
.1.3.6.1.4.1.12356.105.1.110.2.1 |
|
|
|
FORTINET-CORE-MIBFnIndex | .1.3.6.1.4.1.12356.105.1.110.2.1.1 |
|
|
SNMPv2-TCDisplayString | .1.3.6.1.4.1.12356.105.1.110.2.1.2 |
|
|
SNMPv2-TCDisplayString | .1.3.6.1.4.1.12356.105.1.110.2.1.3 |
|
|
Enumeration | .1.3.6.1.4.1.12356.105.1.110.2.1.4 |
|
|
FmlRAIDCodeVal | .1.3.6.1.4.1.12356.105.1.12 |
|
|
OctetString | .1.3.6.1.4.1.12356.105.1.13 |
|
|
FmlHAEventIdVal | .1.3.6.1.4.1.12356.105.1.14 |
|
|
SNMPv2-SMIIpAddress | .1.3.6.1.4.1.12356.105.1.15 |
|
|
OctetString | .1.3.6.1.4.1.12356.105.1.16 |
|
|
OctetString | .1.3.6.1.4.1.12356.105.1.2 |
|
|
.1.3.6.1.4.1.12356.105.1.200 |
|
|
|
FmlHAModeVal | .1.3.6.1.4.1.12356.105.1.200.1 |
|
|
FmlHAModeVal | .1.3.6.1.4.1.12356.105.1.200.2 |
|
|
OctetString | .1.3.6.1.4.1.12356.105.1.3 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.30 |
|
|
Enumeration | .1.3.6.1.4.1.12356.105.1.31 |
|
|
OctetString | .1.3.6.1.4.1.12356.105.1.4 |
|
|
FmlOpMode | .1.3.6.1.4.1.12356.105.1.5 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.6 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.7 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.8 |
|
|
SNMPv2-SMIGauge32 | .1.3.6.1.4.1.12356.105.1.9 |
|
|
.1.3.6.1.4.1.12356.105.600 |
Notifications / Traps (13)
| Name | OID | Description |
|---|---|---|
|
|
.1.3.6.1.4.1.12356.105.0.101 |
Trap being sent if CPU usage becomes too high, which is defined in FORTINET-CORE-MIB |
|
|
.1.3.6.1.4.1.12356.105.0.102 |
Trap being sent if memory usage becomes too high, which is defined in FORTINET-CORE-MIB |
|
|
.1.3.6.1.4.1.12356.105.0.103 |
Trap being sent if Log disk usage becomes too high, which is defined in FORTINET-CORE-MIB |
|
|
.1.3.6.1.4.1.12356.105.0.104 |
Trap being sent if Mailbox disk usage becomes too high |
|
|
.1.3.6.1.4.1.12356.105.0.105 |
Trap being sent if Mail server deferred emails becomes too high |
|
|
.1.3.6.1.4.1.12356.105.0.106 |
Trap being sent when detected virus number reaches the threshold |
|
|
.1.3.6.1.4.1.12356.105.0.107 |
Trap being sent when detected spam email number reaches the threshold |
|
|
.1.3.6.1.4.1.12356.105.0.108 |
Trap being sent when detected a power suply unit failure, which is defined in FORTINET-CORE-MIB |
|
|
.1.3.6.1.4.1.12356.105.0.201 |
Trap being sent when system component halt, reboot, upgrade etc., |
|
|
.1.3.6.1.4.1.12356.105.0.202 |
Trap being sent for RAID operation |
|
|
.1.3.6.1.4.1.12356.105.0.203 |
Trap being sent when HA event occurs |
|
|
.1.3.6.1.4.1.12356.105.0.205 |
Trap being sent when status of the remote storage changes |
|
|
.1.3.6.1.4.1.12356.105.0.301 |
Trap being sent when IP address of the specified interface has been changed, which is defined in FORTINET-CORE-MIB |