omsOperationCommandAlarm
|
.1.3.6.1.4.1.34300.3.20.1 |
mcTrapLParam1 = command <upload=1, download=2, apply=3, confirm=4, save=5>;
mcTrapLParam2 = filetype <pattern=1, private=2, binary=3>
mcTrapDescr = Description of operarion:
DeviceName,
command <upload, download, apply, confirm, save>,
tftp host,
config filename,
status=Error,
cause of error
|
omsOperationCommandOk
|
.1.3.6.1.4.1.34300.3.21.1 |
mcTrapLParam1 = command <upload=1, download=2, apply=3, confirm=4, save=5>;
mcTrapLParam2 = filetype <pattern=1, private=2, binary=3>
mcTrapDescr = Description of operarion:
DeviceName,
command <upload, download, apply, confirm, save>,
tftp host,
config filename,
status=Ok
|
mc240StreamAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.1 |
mc-240 stream alarm trap. Severity: alert
|
mc240SensAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.10 |
mc240 sensor alarm trap (mcTrapExState = sensors bit mask, param1=temp,C, param2=Hum,%)
|
dslamLinkDownTrap
|
.1.3.6.1.4.1.34300.3.3.11 |
dslam link down trap (mcTrapExState = link state, param1 = ADSLport)
|
dslamDSRateAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.12 |
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)
|
dslamUSRateAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.13 |
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)
|
ponONUAuthAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.14 |
Bad registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')
|
ponEthAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.15 |
Eth Link Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down'
|
ponOpticalAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.16 |
The optical link N (mcTrapLParam1) has no active devices
|
dslamOverheatAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.17 |
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)
|
dslamVoltageAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.18 |
when voltage deviation become more 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )
|
dslamSessionAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.19 |
Trap sending when connection happen, mcTrapLParam1 - means connection from (0)-CLI (1)->Webs (2)->SNMP
|
mc240SyncAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.2 |
mc-240 sync alarm trap. Severity: warning
|
dslamEthLinkAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.20 |
Trap sending when switch port link DOWN, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1
|
mc240ss7LinkAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.3 |
mc-240 ss7 link alarm trap. Severity: alert
|
mc240ss7LinksetAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.4 |
mc-240 ss7 linkset alarm trap. Severity: critical
|
mc240FileAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.5 |
mc-240 file alarm trap. Severity: critical
|
mc240CardAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.6 |
mc-240 card alarm trap. Severity: critical
|
mxlDPSAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.7 |
mxl DSL DP system alarm trap
|
mxlTELEAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.8 |
mxl DSL DP system alarm trap
|
mc240UPSAlarmTrap
|
.1.3.6.1.4.1.34300.3.3.9 |
mc240 UPS alarm trap
|
mc240StreamOkTrap
|
.1.3.6.1.4.1.34300.3.4.1 |
mc-240 stream ok trap. Severity: alert
|
mc240SensOkTrap
|
.1.3.6.1.4.1.34300.3.4.10 |
mc240 sensor alarm trap (normal state)
|
dslamLinkUpTrap
|
.1.3.6.1.4.1.34300.3.4.11 |
dslam link up trap (mcTrapExState = link state == 0, param1 = ADSLport)
|
dslamDSRateOkTrap
|
.1.3.6.1.4.1.34300.3.4.12 |
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)
|
dslamUSRateOkTrap
|
.1.3.6.1.4.1.34300.3.4.13 |
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)
|
ponONUAuthOkTrap
|
.1.3.6.1.4.1.34300.3.4.14 |
Normal registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')
|
ponEthOkTrap
|
.1.3.6.1.4.1.34300.3.4.15 |
Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up'
|
ponOpticalOkTrap
|
.1.3.6.1.4.1.34300.3.4.16 |
The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices
|
dslamOverheatOkTrap
|
.1.3.6.1.4.1.34300.3.4.17 |
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)
|
dslamVoltageOkTrap
|
.1.3.6.1.4.1.34300.3.4.18 |
when voltage deviation become less 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )
|
dslamSessionOkTrap
|
.1.3.6.1.4.1.34300.3.4.19 |
Trap sending when connection closed, mcTrapLParam1 - means disconnection from (0)-CLI (1)->Webs (2)->SNMP
|
mc240SyncOkTrap
|
.1.3.6.1.4.1.34300.3.4.2 |
mc-240 sync ok trap. Severity: warning
|
dslamEthLinkOkTrap
|
.1.3.6.1.4.1.34300.3.4.20 |
Trap sending when switch port link UP, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1
|
mc240ss7LinkOkTrap
|
.1.3.6.1.4.1.34300.3.4.3 |
mc-240 ss7 link ok trap. Severity: alert
|
mc240ss7LinksetOkTrap
|
.1.3.6.1.4.1.34300.3.4.4 |
mc-240 ss7 linkset ok trap. Severity: critical
|
mc240FileOkTrap
|
.1.3.6.1.4.1.34300.3.4.5 |
mc-240 file ok trap. Severity: critical
|
mc240CardOkTrap
|
.1.3.6.1.4.1.34300.3.4.6 |
mc-240 card trap. Severity: critical
|
mxlDPSOkTrap
|
.1.3.6.1.4.1.34300.3.4.7 |
mxl DSL DP system alarm trap (normal state)
|
mxlTELEOkTrap
|
.1.3.6.1.4.1.34300.3.4.8 |
mxl DSL DP system alarm trap (normal state)
|
mc240UPSOkTrap
|
.1.3.6.1.4.1.34300.3.4.9 |
mc240 UPS alarm trap (normal state)
|
mp800mkMPStatusAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.1 |
MP operation error.
|
mp800mkDVcellAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.10 |
Battery cell voltage spread is out of range.
|
mp800mkACVAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.11 |
AC voltage is out of range.
|
mp800mkBatChargeAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.12 |
Battery is close to total discharge.
|
mp800mkIloadAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.13 |
Load current is out of range.
|
mp800mkIbatChAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.14 |
Battery charge current is too high.
|
mp800mkSuppAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.15 |
Power supply from battery.
|
mp800mkBatConnAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.16 |
Battery is disconnected from MPs' output.
|
mp800mkInpParmAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.2 |
Incorrect input parameters.
|
mp800mkUEPConfAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.3 |
UEP configuration error.
|
mp800mkTMAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.4 |
Temperature measurement error.
|
mp800mkACVMAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.5 |
ACV measurement error.
|
mp800mkIbatMAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.6 |
Battery current measurement error.
|
mp800mkVbatMAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.7 |
Battery voltage measurement error.
|
mp800mkVbatChAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.8 |
Can't change (increase or decrease) battery voltage.
|
mp800mkRlsDevAlarmTrap
|
.1.3.6.1.4.1.34300.3.8.9 |
Release device is off (battery disconnected).
|
mp800mkMPStatusOkTrap
|
.1.3.6.1.4.1.34300.3.9.1 |
MP operation OK.
|
mp800mkDVcellOkTrap
|
.1.3.6.1.4.1.34300.3.9.10 |
Battery cell voltage spread is in range.
|
mp800mkACVOkTrap
|
.1.3.6.1.4.1.34300.3.9.11 |
AC voltage is in range.
|
mp800mkBatChargeOkTrap
|
.1.3.6.1.4.1.34300.3.9.12 |
Battery charge status is OK.
|
mp800mkIloadOkTrap
|
.1.3.6.1.4.1.34300.3.9.13 |
Load current is in range.
|
mp800mkIbatChOkTrap
|
.1.3.6.1.4.1.34300.3.9.14 |
Battery charge current is in range.
|
mp800mkSuppOkTrap
|
.1.3.6.1.4.1.34300.3.9.15 |
Power supply from MPs.
|
mp800mkBatConnOkTrap
|
.1.3.6.1.4.1.34300.3.9.16 |
Battery is connected to MPs' output.
|
mp800mkInpParmOkTrap
|
.1.3.6.1.4.1.34300.3.9.2 |
Input parameters OK.
|
mp800mkUEPConfOkTrap
|
.1.3.6.1.4.1.34300.3.9.3 |
UEP configuration OK.
|
mp800mkTMOkTrap
|
.1.3.6.1.4.1.34300.3.9.4 |
Temperature measurement OK.
|
mp800mkACVMOkTrap
|
.1.3.6.1.4.1.34300.3.9.5 |
ACV measurement OK.
|
mp800mkIbatMOkTrap
|
.1.3.6.1.4.1.34300.3.9.6 |
Battery current measurement OK.
|
mp800mkVbatMOkTrap
|
.1.3.6.1.4.1.34300.3.9.7 |
Battery voltage measurement OK.
|
mp800mkVbatChOkTrap
|
.1.3.6.1.4.1.34300.3.9.8 |
Battery voltage changing OK.
|
mp800mkRlsDevOkTrap
|
.1.3.6.1.4.1.34300.3.9.9 |
Release device is on.
|