ELTEX-MES-ISS-POE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
4
Rows
4
Columns
13
.1.3.6.1.4.1.35265.1.139.11.1.1.1
·
1 row entry
·
2 columns
A table of objects that control attributes of the PoE PSE group.
An entry in the eltMesIssPoeGlobalConfigTable.
Indexes
eltMesIssPoeGlobalConfigGroupIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
eltMesIssPoeGlobalConfigGroupIndex
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.1.1.1.1 |
||||
|
eltMesIssPoeInrushTest
This object controls PoE Inrush Test status.
If PoE Inrush Test is ENABLED, then at the initialization of the connection, less power is supplied to prevent damaging the connected device |
EltMesIssPoeInrushTestStatusr/w Textual Convention: EltMesIssPoeInrushTestStatus EnumerationType Values:
|
.1.3.6.1.4.1.35265.1.139.11.1.1.1.1.2 |
eltMesIssPoeStatTable
table.1.3.6.1.4.1.35265.1.139.11.1.2.1
·
1 row entry
·
2 columns
The table listing Temperature information for PoE PSE group.
An entry in the eltMEsIssPoeStatTable.
Indexes
eltMesIssPoeStatGroupIndex
| Column | Syntax | OID |
|---|---|---|
|
eltMesIssPoeStatGroupIndex
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.2.1.1.1 |
|
eltMesIssPoeTemperature
This object displays current temperature of the PoE controller.
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.2.1.1.2 |
.1.3.6.1.4.1.35265.1.139.11.1.3.1
·
1 row entry
·
3 columns
A table of objects that control attributes for Power Over Ethernet port.
An entry in the eltMesIssPoePortConfigTable.
Indexes
eltMesIssPoePortConfigGroupIndex eltMesIssPoePortConfigIfIndex
| Column | Syntax | OID |
|---|---|---|
|
eltMesIssPoePortConfigGroupIndex
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.3.1.1.1 |
|
eltMesIssPoePortConfigIfIndex
This variable uniquely identifies the PoE PSE port
within group eltMesIssPoePortUtilGroupIndex to which PoE PSE entry is connected. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.3.1.1.2 |
|
eltMesIssPoePortMaxPowerLimit
This variable indicates on the user configured power level in milli
watts which is available from eltMesIssPoePortConfigIfIndex. The special value of zero is used to set power level threshold according to… |
Integer32r/w Constraints: range: 0-31200 |
.1.3.6.1.4.1.35265.1.139.11.1.3.1.1.3 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1
·
1 row entry
·
6 columns
The table listing Current, Voltage and Power consumption information for Power Over Ethernet port.
An entry in the eltMesIssPoePortUtilTable.
Indexes
eltMesIssPoePortUtilGroupIndex eltMesIssPoePortUtilIfIndex
| Column | Syntax | OID |
|---|---|---|
|
eltMesIssPoePortUtilGroupIndex
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1.1.1 |
|
eltMesIssPoePortUtilIfIndex
This variable uniquely identifies the PoE PSE port
within group eltMesIssPoePortUtilGroupIndex to which PoE PSE entry is connected. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1.1.2 |
|
eltMesIssPoePortUtilOutputVoltage
This variable indicates on the output voltage level in volts.
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1.1.3 |
|
eltMesIssPoePortUtilOutputCurrent
This variable indicates on the output current level in milliamps.
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1.1.4 |
|
eltMesIssPoePortUtilOutputPower
This variable indicates on the output power level in milliwatts.
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1.1.5 |
|
eltMesIssPoePortUtilMaxPower
This variable indicates on the max power in milliwatts
that can be provided. |
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1.1.6 |