DMOS-HW-MONITOR-NOTIFICATIONS-MIB
This MIB file constains the definition of DmOS notifications related to the hardware monitoring.
dmosHwMonNotificationsMIB
1.3.6.1.4.1.3709.3.6.3.3.2
Imported Objects
| DMOS-NOTIFICATIONS-MIB | alarmNotifications notificationAlarmState notificationInfo notificationName notificationSeverity notificationSourceType notificationSourceValue notificationTime |
| SNMPv2-CONF | NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
Objects (5)
|
|
.1.3.6.1.4.1.3709.3.6.3.3.2 |
|
|
|
.1.3.6.1.4.1.3709.3.6.3.3.2.1 |
|
|
|
Integer32 | .1.3.6.1.4.1.3709.3.6.3.3.2.1.1 |
|
|
Integer32 | .1.3.6.1.4.1.3709.3.6.3.3.2.1.2 |
|
|
.1.3.6.1.4.1.3709.3.6.3.3.2.2 |
Notifications / Traps (8)
| Name | OID | Description |
|---|---|---|
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState dmosHwMonValue dmosHwMonLimitValue
|
.1.3.6.1.4.1.3709.3.6.3.3.2.10 |
Alarm for critical temperature of the device. |
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState dmosHwMonValue dmosHwMonLimitValue
|
.1.3.6.1.4.1.3709.3.6.3.3.2.3 |
Alarm for fan speed above the safe rpm speed. |
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState dmosHwMonValue dmosHwMonLimitValue
|
.1.3.6.1.4.1.3709.3.6.3.3.2.4 |
Alarm for fan speed below the safe rpm speed. |
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState
|
.1.3.6.1.4.1.3709.3.6.3.3.2.5 |
Alarm for fan in a fail condition. The fan must be checked. |
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState
|
.1.3.6.1.4.1.3709.3.6.3.3.2.6 |
Alarm to report that an error happened on fan status reading. |
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState dmosHwMonValue dmosHwMonLimitValue
|
.1.3.6.1.4.1.3709.3.6.3.3.2.7 |
Alarm for high temperature of the device. |
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState dmosHwMonValue dmosHwMonLimitValue
|
.1.3.6.1.4.1.3709.3.6.3.3.2.8 |
Alarm for low temperature of the device. |
|
DMOS-NOTIFICATIONS-MIBnotificationTime DMOS-NOTIFICATIONS-MIBnotificationName DMOS-NOTIFICATIONS-MIBnotificationSourceType DMOS-NOTIFICATIONS-MIBnotificationSourceValue DMOS-NOTIFICATIONS-MIBnotificationSeverity DMOS-NOTIFICATIONS-MIBnotificationInfo DMOS-NOTIFICATIONS-MIBnotificationAlarmState
|
.1.3.6.1.4.1.3709.3.6.3.3.2.9 |
It was not possible to read the temperature sensor. |