DGS-6600-EQUIPMENT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
43
.1.3.6.1.4.1.171.10.120.100.1.2.1.1 · 1 row entry · 6 columns
TBD.
chassisControlModuleLEDInfoEntry entry .1.3.6.1.4.1.171.10.120.100.1.2.1.1.1
TBD.
Indexes
chassisControlModuleLEDInfoIndex
Column Syntax OID
chassisControlModuleLEDInfoIndex
This object indicates the slot index of Control Module.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.1
chassisControlModuleLEDInfoConsole
This object indicates the console type. There are two different interfaces:
1: RS232.
2: USB.
Enumeration
Enumerated Values:
1rs232
2usb
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.2
chassisControlModuleLEDInfoMaster
This object indicates whether this control module is master or not?
1: This control module is active CM.
2: This control module is standby CM.
Enumeration
Enumerated Values:
1active
2standby
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.3
chassisControlModuleLEDInfoCPUUtilization
This object indicates the CPU utilization(in percentage) of this control module.
Enumeration
Enumerated Values:
0zero-LED
1one-LED
2two-LEDs
3three-LEDs
4four-LEDs
5five-LEDs
6six-LEDs
7seven-LEDs
8eight-LEDs
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.4
chassisControlModuleLEDInfoMgmtPortStatus
This object indicates the management port status.
Enumeration
Enumerated Values:
1off
2steady-green
3blinking-green
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.5
chassisControlModuleLEDInfoMgmtPortSpeed
This object indicates the management port link speed.
Enumeration
Enumerated Values:
1link-0
2link-100
3link-1000
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.6
.1.3.6.1.4.1.171.10.120.100.1.2.2.1 · 1 row entry · 7 columns
TBD.
chassisPowerInfoEntry entry .1.3.6.1.4.1.171.10.120.100.1.2.2.1.1
TBD.
Indexes
chassisPowerIndex
Column Syntax OID
chassisPowerIndex
This object indicates the PSU index.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.1
chassisPowerExist
This object indicates whether the specified PSU is exist or not.
1: The PSU is not exist.
2: The PSU is installed.
Enumeration
Enumerated Values:
1empty
2exist
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.2
chassisPowerAlive
This object indicates whether the specified PSU is alive or not.
1: The PSU is not available.
2: The PSU is working normally.
Enumeration
Enumerated Values:
1failed
2in-operation
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.4
chassisPowerVoltage
This object indicates the output voltage(V) of the specified PSU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.5
chassisPowerCurrent
This object indicates the output current(mA) of the specified PSU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.6
chassisPowerPowerWatt
This object indicates the output power(W) of the specified PSU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.7
chassisPowerFanSpeed
This object indicates the internal fan speed(rpm) of specified PSU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.8
.1.3.6.1.4.1.171.10.120.100.1.2.3.2 · 1 row entry · 3 columns
TBD.
chassisFanInfoEntry entry .1.3.6.1.4.1.171.10.120.100.1.2.3.2.1
TBD.
Indexes
chassisFanIndex
Column Syntax OID
chassisFanIndex
This object indicates the fan tray index.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.1
chassisFanStatus
This object indicates the fan status(ok or failed).
Enumeration
Enumerated Values:
1failed
2ok
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.2
chassisFanSpeed
This object indicates the fan speed in RPM.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.3
.1.3.6.1.4.1.171.10.120.100.1.2.4.1 · 1 row entry · 12 columns
TBD.
chassisSlotInfoEntry entry .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1
TBD.
Indexes
chassisSlotIndex
Column Syntax OID
chassisSlotIndex
This object indicates the slot index.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.1
chassisSlotState
This object indicates the slot state:
1: The slot has no card installed.
2: The card which installed at this slot is not powered up.
3: The card which installed at this slot is failed.
4: The card which installed at thi…
Enumeration
Enumerated Values:
1empty
2no-power
3failed
4booting
5in-operation
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.2
chassisSlotLEDPoEModeEnabled
This object indicates whether the PoE mode is enabled or not?
Enumeration
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.3
chassisSlotModel
This object indicates the card model name.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.4
chassisSlotSerialNumber
This object indicates the serial number of the installed card.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.5
chassisSlotHwVersion
This object indicates the HW version of the installed card.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.6
chassisSlotPCBAVersion
This object indicates the PCBA version of the installed card.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.7
chassisSlotBootloaderVersion
This object indicates the PCBA version of the installed card.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.8
chassisSlotRuntimeVersion
This object indicates the runtime version of the installed card.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.9
chassisSlotCPLDVersion
This object indicates the CPLD version of the installed card.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.10
chassisSlotFirsMacAddress
This object indicates the first MAC address of the installed card.
SNMPv2-TCMacAddress
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.11
chassisSlotNumberOfMacAddress
This object indicates the number of MAC address of the installed card.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.12
.1.3.6.1.4.1.171.10.120.100.1.2.5.1 · 1 row entry · 10 columns
TBD.
chassisTemperatureInfoEntry entry .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1
TBD.
Indexes
chassisTemperatureSlotIndex
Column Syntax OID
chassisTemperatureSlotIndex
This object indicates the slot number which is currently querying.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.1
chassisTemperatureInletCurrent
This object displays the current temperature of Inlet sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.2
chassisTemperatureInletOverheat
This object displays the overheat threshold of Inlet sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.3
chassisTemperatureInletHeatdown
This object displays the heatdown threshold of Inlet sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.4
chassisTemperatureCenterCurrent
This object displays the current temperature of Center sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.5
chassisTemperatureCenterOverheat
This object displays the overheat threshold of Center sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.6
chassisTemperatureCenterHeatdown
This object displays the heatdown threshold of Center sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.7
chassisTemperatureOutletCurrent
This object displays the current temperature of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.8
chassisTemperatureOutletOverheat
This object displays the overheat threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.9
chassisTemperatureOutletHeatdown
This object displays the outlet threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.10
.1.3.6.1.4.1.171.10.120.100.1.2.6.1 · 1 row entry · 5 columns
TBD.
chassisPortLEDInfoEntry entry .1.3.6.1.4.1.171.10.120.100.1.2.6.1.1
TBD.
Indexes
chassisPortLEDIFIndex
Column Syntax OID
chassisPortLEDIFIndex
This object indicates the interface index.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.1
chassisPortLEDIFName
This object indicates the interface name.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.2
chassisPortLEDStatus
This object indicates the port LED status:
1: The port LED status of the interface index is off.
2: The port LED status of the interface index is steady-amber.
3: The port LED status of the interface index is steady-gr…
Enumeration
Enumerated Values:
1off
2steady-amber
3steady-green
4blinking-amber
5blinking-green
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.3
chassisPortLEDMode
This object indicates the port LED mode:
1: The port LED is in Ethernet mode.
2: The poer LED is in PoE mode.
Enumeration
Enumerated Values:
1ethernet
2poe
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.4
chassisPortLEDMediumType
This object indicates the port LED medium type:
1: The medium type of port LED is copper.
2: The medium type of port LED is fiber.
Enumeration
Enumerated Values:
1copper
2fiber
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.5