DELL-STORAGE-SC-MIB

        The MIB is for monitoring the status of Storage
Center products from Dell Storage.
    
storageCenterModule 1.3.6.1.4.1.674.11000.2000.500.1.1
Imported Objects
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-CONF MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-MIB sysName
SNMPv2-SMI enterprises MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE Unsigned32
SNMPv2-TC DateAndTime TEXTUAL-CONVENTION TruthValue
Type Definitions (2)
ScHardwareType Enumeration
fan(1)
powersupply(2)
tempsensor(3)
voltagesensor(4)
iomodule(5)
audiblealarm(6)
ScStatus Enumeration
up(1)
down(2)
degraded(3)
Objects (268)
dellEnterprise .1.3.6.1.4.1.674
dellEnterpriseBranch .1.3.6.1.4.1.674.11000
dellStorageSubBranch .1.3.6.1.4.1.674.11000.2000
compellentEnterprise .1.3.6.1.4.1.674.11000.2000.500
storageCenter .1.3.6.1.4.1.674.11000.2000.500.1
storageCenterModule .1.3.6.1.4.1.674.11000.2000.500.1.1
storageCenterObjects .1.3.6.1.4.1.674.11000.2000.500.1.2
productIDDisplayName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.1
scIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.10
scTestString SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.11
scMiscAlertString SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.12
scCtlrTable .1.3.6.1.4.1.674.11000.2000.500.1.2.13
scCtlrEntry scCtlrIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1
scCtlrIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.1
scCtlrIPv6Eth0IP SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.10
scCtlrIPv6Eth0IPPrefix Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.11
scCtlrLeader SNMPv2-TCTruthValue .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.12
scCtlrNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.2
scCtlrStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.3
scCtlrName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.4
scCtlrIpAddr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.5
scCtlrForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.6
scCtlrModel SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.7
scCtlrServiceTag SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.8
scCtlrAssetTag SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.13.1.9
scDiskTable .1.3.6.1.4.1.674.11000.2000.500.1.2.14
scDiskEntry scDiskIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1
scDiskIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.1
scDiskIoPortType Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.10
scDiskEnclosure Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.11
scDiskNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.2
scDiskStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.3
scDiskNamePosition SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.4
scDiskHealthy SNMPv2-TCTruthValue .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.5
scDiskStatusMsg SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.6
scDiskApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.7
scDiskForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.8
scDiskSize Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.14.1.9
scEnclTable .1.3.6.1.4.1.674.11000.2000.500.1.2.15
scEnclEntry scEnclIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1
scEnclIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.1
scEnclAssetTag SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.10
scEnclApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.11
scEnclNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.2
scEnclStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.3
scEnclName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.4
scEnclStatusDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.5
scEnclType SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.6
scEnclModel SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.7
scEnclForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.8
scEnclServiceTag SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.15.1.9
scCtlrFanTable .1.3.6.1.4.1.674.11000.2000.500.1.2.16
scCtlrFanEntry scCtlrIndexscCtlrFanIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1
scCtlrFanIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.1
scCtlrFanCritLwrRpm Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.10
scCtlrFanCritUprRpm Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.11
scCtlrFanForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.12
scCtlrFanApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.13
scCtlrFanNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.2
scCtlrFanStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.3
scCtlrFanName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.4
scCtlrFanCurrentRpm Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.5
scCtlrFanNormMaxRpm Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.6
scCtlrFanNormMinRpm Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.7
scCtlrFanWarnLwrRpm Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.8
scCtlrFanWarnUprRpm Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.16.1.9
scCtlrPowerTable .1.3.6.1.4.1.674.11000.2000.500.1.2.17
scCtlrPowerEntry scCtlrIndexscCtlrPowerIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1
scCtlrPowerIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.1
scCtlrPowerNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.2
scCtlrPowerStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.3
scCtlrPowerName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.4
scCtlrPowerForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.17.1.5
scCtlrVoltageTable .1.3.6.1.4.1.674.11000.2000.500.1.2.18
scCtlrVoltageEntry scCtlrIndexscCtlrVoltageIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1
scCtlrVoltageIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.1
scCtlrVoltageCritLwrV SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.10
scCtlrVoltageCritUprV SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.11
scCtlrVoltageForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.12
scCtlrVoltageNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.2
scCtlrVoltageStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.3
scCtlrVoltageName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.4
scCtlrVoltageCurrentV SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.5
scCtlrVoltageNormMaxV SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.6
scCtlrVoltageNormMinV SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.7
scCtlrVoltageWarnLwrV SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.8
scCtlrVoltageWarnUprV SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.18.1.9
scCtlrTempTable .1.3.6.1.4.1.674.11000.2000.500.1.2.19
scCtlrTempEntry scCtlrIndexscCtlrTempIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1
scCtlrTempIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.1
scCtlrTempCritLwrC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.10
scCtlrTempCritUprC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.11
scCtlrTempForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.12
scCtlrTempNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.2
scCtlrTempStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.3
scCtlrTempName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.4
scCtlrTempCurrentC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.5
scCtlrTempNormMaxC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.6
scCtlrTempNormMinC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.7
scCtlrTempWarnLwrC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.8
scCtlrTempWarnUprC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.19.1.9
productIDDescription SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.2
scEnclFanTable .1.3.6.1.4.1.674.11000.2000.500.1.2.20
scEnclFanEntry scEnclIndexscEnclFanIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.20.1
scEnclFanIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.1
scEnclFanNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.2
scEnclFanStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.3
scEnclFanLocation SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.4
scEnclFanCurrentS SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.5
scEnclFanForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.20.1.6
scEnclPowerTable .1.3.6.1.4.1.674.11000.2000.500.1.2.21
scEnclPowerEntry scEnclIndexscEnclPowerIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.21.1
scEnclPowerIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.21.1.1
scEnclPowerNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.21.1.2
scEnclPowerStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.21.1.3
scEnclPowerPosition SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.21.1.4
scEnclPowerForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.21.1.5
scEnclIoModTable .1.3.6.1.4.1.674.11000.2000.500.1.2.22
scEnclIoModEntry scEnclIndexscEnclIoModIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.22.1
scEnclIoModIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.22.1.1
scEnclIoModNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.22.1.2
scEnclIoModStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.22.1.3
scEnclIoModPosition SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.22.1.4
scEnclIoModForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.22.1.5
scEnclTempTable .1.3.6.1.4.1.674.11000.2000.500.1.2.23
scEnclTempEntry scEnclIndexscEnclTempIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.23.1
scEnclTempIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.1
scEnclTempNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.2
scEnclTempStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.3
scEnclTempLocation SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.4
scEnclTempCurrentC Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.5
scEnclTempForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.23.1.6
scEnclAlarmTable .1.3.6.1.4.1.674.11000.2000.500.1.2.24
scEnclAlarmEntry scEnclIndexscEnclAlarmIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.24.1
scEnclAlarmIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.24.1.1
scEnclAlarmNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.24.1.2
scEnclAlarmStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.24.1.3
scEnclAlarmName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.24.1.4
scEnclAlarmForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.24.1.5
scDiskFolderTable .1.3.6.1.4.1.674.11000.2000.500.1.2.25
scDiskFolderEntry scDiskFolderIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1
scDiskFolderIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.1
scDiskFolderNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.2
scDiskFolderStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.3
scDiskFolderName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.4
scDiskFolderCapcty deprecated Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.5
scDiskFolderAlrtThr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.6
scDiskFolderApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.7
scDiskFolderForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.8
scDiskFolderCapcty2 Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.25.1.9
scVolumeTable .1.3.6.1.4.1.674.11000.2000.500.1.2.26
scVolumeEntry scVolumeIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.26.1
scVolumeIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.1
scVolumeNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.2
scVolumeStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.3
scVolumeName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.4
scVolumeApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.5
scVolumeForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.26.1.6
scServerTable .1.3.6.1.4.1.674.11000.2000.500.1.2.27
scServerEntry scServerIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1
scServerIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.1
scServerNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.2
scServerStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.3
scServerName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.4
scServerCnctvy Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.5
scServerPathCount Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.6
scServerApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.7
scServerForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.27.1.8
scCacheTable .1.3.6.1.4.1.674.11000.2000.500.1.2.28
scCacheEntry scCacheIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1
scCacheIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.1
scCacheNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.2
scCacheStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.3
scCacheName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.4
scCacheBatStat Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.5
scCacheBatExpr SNMPv2-TCDateAndTime .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.6
scCacheForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.28.1.7
scScTable .1.3.6.1.4.1.674.11000.2000.500.1.2.29
scScEntry scScIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1
scScIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.1
scScForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.10
scScIPv6MgmtIP SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.11
scScIPv6MgmtIPPrefix Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.12
scScNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.2
scScStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.3
scScName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.4
scScContact SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.5
scScLocation SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.6
scScPortsBal SNMPv2-TCTruthValue .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.7
scScMgmtIP SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.8
scScSerial Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.29.1.9
productIDVendor SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.3
scUPSTable .1.3.6.1.4.1.674.11000.2000.500.1.2.30
scUPSEntry scUPSIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1
scUPSIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.1
scUPSNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.2
scUPSStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.3
scUPSName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.4
scUPSBatLife SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.5
scUPSStatusDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.6
scUPSApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.7
scUPSForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.30.1.8
scObjCntTable .1.3.6.1.4.1.674.11000.2000.500.1.2.31
scObjCntEntry scObjCntIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1
scObjCntIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.1
scObjCntNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.2
scObjCntDevsInUse Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.3
scObjCntReplays Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.4
scObjCntDisks Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.5
scObjCntServers Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.6
scObjCntVolumes Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.31.1.7
scDiskFolderSUTable .1.3.6.1.4.1.674.11000.2000.500.1.2.32
scDiskFolderSUEntry scDiskFolderSUIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1
scDiskFolderSUIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.1
scDiskFolderSUNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.2
scDiskFolderSUTotalSpace deprecated Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.3
scDiskFolderSUUsedSpace deprecated Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.4
scDiskFolderSUTotalSpace2 Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.5
scDiskFolderSUUsedSpace2 Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.6
scDiskFolderSUAllocSpace Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.7
scDiskFolderSUFreeSpace Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.8
scDiskFolderSUSpareSpace Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.32.1.9
scSIDeviceType Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.33
scSIDeviceStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.34
scHWCompStatus ScStatus .1.3.6.1.4.1.674.11000.2000.500.1.2.35
scHWCompName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.36
scHWCompPosition SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.37
scHWCompType ScHardwareType .1.3.6.1.4.1.674.11000.2000.500.1.2.38
scHWCompState SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.39
productIDVersion SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.4
scTrapAction SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.40
scAlertMsg SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.41
scForceTrap r/w SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.42
scTrapNormalized SNMPv2-TCTruthValue .1.3.6.1.4.1.674.11000.2000.500.1.2.43
scLastWorstAlert Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.44
scDiskConfigTable .1.3.6.1.4.1.674.11000.2000.500.1.2.45
scDiskConfigEntry scDiskConfigIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1
scDiskConfigIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.1
scDiskConfigNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.2
scDiskConfigSerial SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.3
scDiskConfigVendor SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.4
scDiskConfigProduct SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.5
scDiskConfigModel SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.6
scDiskConfigRev SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.7
scDiskConfigApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.45.1.8
scAlertTable .1.3.6.1.4.1.674.11000.2000.500.1.2.46
scAlertEntry scCtlrIndexscAlertIndex .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1
scAlertIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.1
scAlertAcknowledged SNMPv2-TCTruthValue .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.10
scAlertActive SNMPv2-TCTruthValue .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.11
scAlertNbr Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.2
scAlertStatus Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.3
scAlertApiIndex Unsigned32 .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.4
scAlertDefinition SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.5
scAlertCategory Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.6
scAlertCreateTime SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.7
scAlertMessage SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.8
scAlertType Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.46.1.9
productIDSerialNumber SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.5
productIDGlobalStatus Enumeration .1.3.6.1.4.1.674.11000.2000.500.1.2.6
productIDBuildNumber SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.7
productIDURL SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.8
scAlertDef SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.674.11000.2000.500.1.2.9
storageCenterTrapsNotif .1.3.6.1.4.1.674.11000.2000.500.1.251
trapSevPrefix .1.3.6.1.4.1.674.11000.2000.500.1.251.0
storageCenterConformance .1.3.6.1.4.1.674.11000.2000.500.1.3
storageCenterCompliances .1.3.6.1.4.1.674.11000.2000.500.1.3.1
storageCenterGroups .1.3.6.1.4.1.674.11000.2000.500.1.3.2
Notifications / Traps (24)
NameOIDDescription
trapStatusOkay
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.1
Deprecated: Storage Center Trap in Okay state.
trapStatusTest
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.100
Deprecated: Storage Center Trap in Test state.
trapStatusTestSpecific
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.101
Deprecated: Storage Center Trap in Test Specific state.
trapStatusDegraded
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.2
Deprecated: Storage Center Trap in Degraded state.
scTestTrap .1.3.6.1.4.1.674.11000.2000.500.1.251.0.200
Test Trap.
scMiscAlert .1.3.6.1.4.1.674.11000.2000.500.1.251.0.201
This trap is used for all alerts that have no
other specific trap definition associated with them
scDiskStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.202
Disk status change.
scCtlrStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.203
Controller status change.
scCtlrCompStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.204
Controller Component status change.
scHWCompState contains current component state
when scHWCompType = tempsensor, voltagesensor,
or fan.
scEnclStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.205
Enclosure status change.
scEnclCompStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.206
Enclosure Component status change.
scHWCompState contains current temperature
when scHWCompType = tempsensor.
scDiskFolderStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.207
Disk Folder status change.
scVolumeStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.208
Volume status change.
scServerStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.209
Managed Server status change.
scCacheStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.210
Cache status change.
scLocalPortCondStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.211
Local Front-end Port Condition status change.
scMonitoredUPSStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.212
Monitored UPS status change.
scSIDeviceStatusChange .1.3.6.1.4.1.674.11000.2000.500.1.251.0.213
SCSI Initiator Device status change.
trapStatusDown
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.3
Deprecated: Storage Center Trap in Down state.
trapStatusInform
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.4
Deprecated: Storage Center Trap in Inform state.
trapStatusCritical
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.5
Deprecated: Storage Center Trap in Critical state.
trapStatusComplete
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.6
Deprecated: Storage Center Trap in Complete state.
trapStatusEmergency
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.7
Deprecated: Storage Center Trap in Emergency state.
trapStatusUnavailable
SNMPv2-MIBsysName
.1.3.6.1.4.1.674.11000.2000.500.1.251.0.8
Deprecated: Storage Center Trap in Unavailable state.