DASAN-NOTIFICATION-V1

Imported Objects
DASAN-GEPON-MIB dsPonCount dsPonDirection dsPonOltIndex dsPonOnuIndex dsPonOnuMacAddress dsPonPortIndex dsPonQueueIndex dsPonState dsPonTaggedLabel
DASAN-SMI dasanEvents
DASAN-SWITCH-MIB dsFanIndex dsFanstatus dsFreeMem dsPortInstallStatus dsPortModuleIndex dsPortPortIndex dsPowerIndex dsPowerstatus dsSubnetConfName dsSwitchAtMacAddress dsSwitchAtNetAddress dsSwitchAtVID dsSystemUpgradePath dsSystemUpgradeStorage dsTemperatureStatus dsUserMacAddress1 dsUserMacAddress2 dsUserMacAddress3 dsUserMacAddress4
DASAN-USER-MANAGEMENT-MIB dsUserLoginIpAddress dsUserLoginName
IF-MIB ifIndex
SNMPv2-MIB sysDescr sysUpTime
SNMPv2-SMI enterprises MODULE-IDENTITY OBJECT-IDENTITY
Objects (0)
Notifications / Traps (223)
NameOIDDescription
portInstalledTrap
IF-MIBifIndex DASAN-SWITCH-MIBdsPortInstallStatus
.1.3.6.1.4.1.6296.0.0.1
portInstalled trap send when portInstallStatus is enabled.
fanRemovedTrap
DASAN-SWITCH-MIBdsFanIndex
.1.3.6.1.4.1.6296.0.0.10
Fan removed trap when fan was removed.
clockModuleInstalled .1.3.6.1.4.1.6296.0.0.105
clockModuleInstalled trap send when sleClockModuleInstallStatus is installed.
clockModuleRemoved .1.3.6.1.4.1.6296.0.0.106
clockModuleRemoved trap send when sleClockModuleInstallStatus is removed.
clockModuleInitOk .1.3.6.1.4.1.6296.0.0.107
clockModuleInitOk trap send when sleClockModuleInitStatus is ok.
clockModuleInitFail .1.3.6.1.4.1.6296.0.0.108
clockModuleInitFail trap send when sleClockModuleInitStatus is failure.
interfaceAdminUp .1.3.6.1.4.1.6296.0.0.109
This trap indicates the interface admin up.
bcastOverTrap
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.11
Broadcast packet over trap when Rx broadcast packet is over the given limit.
interfaceAdminDown .1.3.6.1.4.1.6296.0.0.110
This trap indicates the interface admin down.
powerMonEventDetected .1.3.6.1.4.1.6296.0.0.111
This trap indicates the power monitoring detects voltage change of slot.
ntpConnectionFail .1.3.6.1.4.1.6296.0.0.112
This trap indicates the ntp connection is lost.
fanSpeedFallUnderThreshold .1.3.6.1.4.1.6296.0.0.113
This trap indicates the fan speed is under the threshold.
fanSpeedRisingOverThreshold .1.3.6.1.4.1.6296.0.0.114
This trap indicates the fan speed is over the threshold.
userLoginFail
DASAN-USER-MANAGEMENT-MIBdsUserLoginName DASAN-USER-MANAGEMENT-MIBdsUserLoginIpAddress
.1.3.6.1.4.1.6296.0.0.115
This trap indicates the user fail to login.
bfdSessionStateChanged .1.3.6.1.4.1.6296.0.0.116
This trap indicates that BFD session state is changed.
clockModuleOPModeChanged .1.3.6.1.4.1.6296.0.0.117
This trap indicate that slot Operation mode is changed.
clockModuleRefrencesChanged .1.3.6.1.4.1.6296.0.0.118
This trap indicate that slot reference ntr is changed.
cpuLoadOverThresholdTrap
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.12
The cpuLoadoverThreshold trap is sentwhen cpuLoad is over the given limit.
portRxOverThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.121
Port Rx traffic over HighThreshold trap when port traffic is over the given limit.
portRxFallThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.122
Port Rx traffic fall under HighThreshold trap when port traffic falls below the given limit.
portTxOverThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.123
Port Tx traffic over HighThreshold trap when port traffic is over the given limit.
portTxFallThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.124
Port Tx traffic fall under HighThreshold trap when port traffic falls below the given limit.
clockModuleInSrcStatusChanged .1.3.6.1.4.1.6296.0.0.125
This trap indicate that BFD reference ntr is changed.
clockModuleInSrcAISStatusChanged .1.3.6.1.4.1.6296.0.0.126
This trap indicate that BFD reference ntr is changed.
clockModuleInSrcLoSStatusChanged .1.3.6.1.4.1.6296.0.0.127
This trap indicate that BFD reference ntr is changed.
clockModuleInSrcLDSCStatus .1.3.6.1.4.1.6296.0.0.128
This trap indicate that BFD reference ntr is changed.
clockModuleInSrcNtrClockchanged .1.3.6.1.4.1.6296.0.0.129
This trap indicate that BFD reference ntr is changed.
cpuLoadFallThresholdTrap
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.13
The cpuLoadfallThreshold trap is sent when cpuLoad fall under the given limit.
dhcpLeaseShortageTrap .1.3.6.1.4.1.6296.0.0.14
DHCP User IP pool shortage when User's DHCPDISCOVER message arrive.
portOverThresholdTrap
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.15
Port traffic over HighThreshold trap when port traffic is over the given limit.
ponLinkFault
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.151
ONU reports a Link Fault via the flag in the 802.3ah OAM header.No further information about the fault is available..
ponLos
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.152
Loss of Signal is detected by the PHY device for OLT Network  interface, and PON interfaces on  the OLT and ONU.
ponTransmitFail
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.153
Transmitted output does not match input, as reported by EPON optics
ponTransmitDegrade
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.154
Transmitted output has a high error level, but not so high as to cause - Failure. Optionallyreported by EPON optical module..
ponQueueOverflow
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.155
One of the queues for the link has dropped frames due to becoming full
ponMacLearningTableOverflow
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.156
MAC address learning table is full, not in overwrite mode, and a new MAC address wasencountered
ponDuplicateMacRegistration
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.157
MPCP register request received for MAC that is registered and in-service
ponReportTimeout
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.158
ONU does not respond to grants from the OLT
ponGateTimeout
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.159
Excessive interval between MPCP gates.
portFallThresholdTrap
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.16
Port traffic fall under HighThreshold trap when port traffic fall under the given limit.
ponOAMKeepaliveTimeout
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.160
OAM KeepaliveTimeout - OAM layer does not receive periodic messages from its peer
ponKeyExchangeFailure
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.161
The link peer has failed to generate a new key message, or to switch to the new key, in the timeallotted by the key exchange timer for this link. Encryption remains in force using the old key, and the key exchange process continues.The alarm will clear when a new key is established.
ponAutoNegotiation
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.162
OLT Network port fails to auto-negotiate with the peer (if auto-negotiation feature is enabled).
ponLinkLoopback
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.163
The link is currently in the loopback state
ponStandardDyingGasp
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.164
ONU reports Dying Gasp via that bit in 802.3ah OAM header
ponPowerFail
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.165
Power supply failure
ponTemperature
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.166
Operating temperature range exceeded
ponAuthenticationInformationUnavailable
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.167
ONU is configured to use external authentication device, and that device is not present
temperatureOverThresholdTrap
DASAN-SWITCH-MIBdsTemperatureStatus
.1.3.6.1.4.1.6296.0.0.17
TemperatureOverThreshold Trap is sent when temperature is over the certain threshold.
ponOctetsTransferred
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.171
Octets Transferred
ponTotalFramesTransferred
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.172
Total frames transferred
ponUnicastFramesTransferred
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.173
Unicast frames transferred
ponBroadcastFramesTransferred
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.174
Broadcast frames transferred
ponMulticastFramesTransferred
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.175
Multicast frames transferred
ponCRC32Errors
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.176
CRC-32 Errors
ponUndersizeFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.177
Undersize Frames
ponOversizeFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.178
Oversize Frames
ponCollisions
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.179
Collisions
systemRestartTrap
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.18
SystemRestart Trap is sent when system is restarted by user.
pon64OctetFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.180
64 Octet Frames
pon127OctetFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.181
65-127 Octet Frames
pon255OctetFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.182
128-255 Octet Frames
pon511OctetFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.183
256-511 Octet Frames
pon1023OctetFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.184
512-1023 Octet Frames
pon1518OctetFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.185
1024-1518 Octet Frames
pon1519OverOctetFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.186
1519+ Octet Frames
ponFramesDropped
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.187
Frames dropped
ponOctetsDropped
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.188
Octets dropped
ponOctetsDelayed
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.189
Octets delayed
mfgdBlockedTrap
DASAN-SWITCH-MIBdsSwitchAtMacAddress DASAN-SWITCH-MIBdsSwitchAtNetAddress DASAN-SWITCH-MIBdsSwitchAtVID
.1.3.6.1.4.1.6296.0.0.19
mfgdblocked Trap is sent when a certain mac address is denied by mac-flood-guard mechanism.
ponOctetsGranted
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.190
Octets granted
ponOctetsGrantedButUnused
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.191
Octets granted but unused
ponMaximumDelay
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.192
Maximum Delay (units of 100usec)
ponCRC8Errors
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.193
CRC-8 (preamble) Errors
ponLineCodeErrors
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.194
Line code errors
ponPauseFrames
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.195
Pause Frames
ponErroredFrameSeconds
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.196
Errored Frame Seconds
ponErroredFramePeriod
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.197
Errored Frame Period
ponErroredFrameSecondsSummary
DASAN-GEPON-MIBdsPonOltIndex DASAN-GEPON-MIBdsPonOnuIndex DASAN-GEPON-MIBdsPonOnuMacAddress DASAN-GEPON-MIBdsPonTaggedLabel DASAN-GEPON-MIBdsPonPortIndex DASAN-GEPON-MIBdsPonQueueIndex DASAN-GEPON-MIBdsPonDirection DASAN-GEPON-MIBdsPonState DASAN-GEPON-MIBdsPonCount
.1.3.6.1.4.1.6296.0.0.198
Errored Frame Seconds Summary
portRemovedTrap
IF-MIBifIndex DASAN-SWITCH-MIBdsPortInstallStatus
.1.3.6.1.4.1.6296.0.0.2
portInstalled trap send when portInstallStatus is disabled.
mfgdReleasedTrap
DASAN-SWITCH-MIBdsSwitchAtMacAddress DASAN-SWITCH-MIBdsSwitchAtNetAddress DASAN-SWITCH-MIBdsSwitchAtVID
.1.3.6.1.4.1.6296.0.0.20
mfgdblocked Trap is sent when a certain mac address is permitted again by mac-flood-guard mechanism.
gponOnuRegistered .1.3.6.1.4.1.6296.0.0.200
Registered Onu Information
gponOnuDeregistered .1.3.6.1.4.1.6296.0.0.201
Deregistered Onu Information
swWatchdogDetectError .1.3.6.1.4.1.6296.0.0.202
S/W Watchdog Detect Error
swWatchdogClearError .1.3.6.1.4.1.6296.0.0.203
S/W Watchdog Clear Error
swWatchdogNormalState .1.3.6.1.4.1.6296.0.0.204
S/W Watchdog Normal State
swWatchdogAbnormalState .1.3.6.1.4.1.6296.0.0.205
S/W Watchdog Abnormal State
gponOnuUpgradeCompleted .1.3.6.1.4.1.6296.0.0.206
Upgrade Completed Onu Informations
gponOltCableDown .1.3.6.1.4.1.6296.0.0.207
GPON Cable down event is detected
gponOnuAutoToManual .1.3.6.1.4.1.6296.0.0.208
GPON Onu is auto-to-manual
slotActionEvent .1.3.6.1.4.1.6296.0.0.209
This trap indicates the slot action event
ipConflictTrap
DASAN-SWITCH-MIBdsSwitchAtNetAddress DASAN-SWITCH-MIBdsSwitchAtMacAddress
.1.3.6.1.4.1.6296.0.0.21
ipConflict Trap is sent when a certain IP address is shared among different users.
slotStateChanged .1.3.6.1.4.1.6296.0.0.210
This trap indicates the slot state is changed
gponNoAuthONU .1.3.6.1.4.1.6296.0.0.211
No authenticated ONU
gponDuplicateONU .1.3.6.1.4.1.6296.0.0.212
Duplicated ONU
gponDyingGasp .1.3.6.1.4.1.6296.0.0.213
Dying Gasp of GPON ONU
gponRogueOnu .1.3.6.1.4.1.6296.0.0.214
Found Rogue ONU.
gponOnuBatteryEvent .1.3.6.1.4.1.6296.0.0.215
Battery Event.
gponOnuBatteryEventCleared .1.3.6.1.4.1.6296.0.0.216
Battery Event is cleared.
gponOnuPortOperStatus .1.3.6.1.4.1.6296.0.0.217
This trap indicates state of ONU Port Operation.
gponTransceiverChanged .1.3.6.1.4.1.6296.0.0.218
This trap indicates GPON transceiver changed.
gponOltLosOn .1.3.6.1.4.1.6296.0.0.219
This trap indicates state of OLT Log Of Signal (on).
dhcpIllegalEntryTrap
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.22
dhcpIllegalEntry trap is sent when illegal dhcp user is found.
gponOltLosOff .1.3.6.1.4.1.6296.0.0.220
This trap indicates state of OLT Log Of Signal (off).
gponOltLosiOn .1.3.6.1.4.1.6296.0.0.221
This trap indicates state of OLT Log Of Signal for ONUi (on).
gponOltLosiOff .1.3.6.1.4.1.6296.0.0.222
This trap indicates state of OLT Log Of Signal for ONUi (off).
gponDyingGaspOn .1.3.6.1.4.1.6296.0.0.223
This trap indicates Dying Gasp of GPON ONU (on).
gponDyingGaspOff .1.3.6.1.4.1.6296.0.0.224
This trap indicates Dying Gasp of GPON ONU (off).
slotErrorLEDChanged .1.3.6.1.4.1.6296.0.0.225
This trap indicates slot error LED changed.
nmsConnectionTypeChanged .1.3.6.1.4.1.6296.0.0.226
This trap indicates NMS connection type changed.
gponOntOSUpgradeStatus .1.3.6.1.4.1.6296.0.0.227
This trap indicates ONT OS upgrade status changes.
gponOntBLUpgradeStatus .1.3.6.1.4.1.6296.0.0.228
This trap indicates ONT BL upgrade status changes.
gponOntRxPowerLoss .1.3.6.1.4.1.6296.0.0.229
This trap indicates ONT port failed to detect Rx Power.
optionModuleInstalledTrap
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.23
optionModuleInstalled Trap is sent when option Module was installed.
gponOntRxPowerDetected .1.3.6.1.4.1.6296.0.0.230
This trap indicates ONT port detected Rx Power.
gponOnuTemperatureHighOverThreshold .1.3.6.1.4.1.6296.0.0.231
This trap indicates the temperature of ONU is over high threshold.
gponOnuTemperatureHighFallThreshold .1.3.6.1.4.1.6296.0.0.232
This trap indicates the temperature of ONU falls under high threshold.
gponOnuTemperatureLowOverThreshold .1.3.6.1.4.1.6296.0.0.233
This trap indicates the temperature of ONU is over low threshold.
gponOnuTemperatureLowFallThreshold .1.3.6.1.4.1.6296.0.0.234
This trap indicates the temperature of ONU falls under low threshold.
gponOnuCpuOverThreshold .1.3.6.1.4.1.6296.0.0.235
This trap indicates the CPU-load of ONU is over threshold.
gponOnuCpuFallThreshold .1.3.6.1.4.1.6296.0.0.236
This trap indicates the CPU-load of ONU falls under threshold.
gponOnuMemoryOverThreshold .1.3.6.1.4.1.6296.0.0.237
This trap indicates the memory-utilization of ONU is over threshold.
gponOnuMemoryFallThreshold .1.3.6.1.4.1.6296.0.0.238
This trap indicates the memory-utilization of ONU falls under threshold.
gponOnuI2cFail .1.3.6.1.4.1.6296.0.0.239
This trap indicates that detect ONU's i2c fail.
optionModuleRemovedTrap
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.24
optionModuleRemoved Trap is sent when option Module was removed.
gponOnuRxOpticPowerLowThreshAlarmOn .1.3.6.1.4.1.6296.0.0.240
This trap indicates that ONU's low threshold Rx Optic power Alarm is On.
gponOnuRxOpticPowerLowThreshAlarmOff .1.3.6.1.4.1.6296.0.0.241
This trap indicates that ONU's low threshold Rx Optic power Alarm is Off.
gponOnuRxOpticPowerHighThreshAlarmOn .1.3.6.1.4.1.6296.0.0.242
This trap indicates that ONU's high threshold Rx Optic power Alarm is On.
gponOnuRxOpticPowerHighThreshAlarmOff .1.3.6.1.4.1.6296.0.0.243
This trap indicates that ONU's high threshold Rx Optic power Alarm is Off.
gponOltLOFIOn .1.3.6.1.4.1.6296.0.0.244
Description
gponOltLOFIOff .1.3.6.1.4.1.6296.0.0.245
Description
gponOltDOWOn .1.3.6.1.4.1.6296.0.0.246
Description
gponOltDOWOff .1.3.6.1.4.1.6296.0.0.247
Description
gponOltSFOn .1.3.6.1.4.1.6296.0.0.248
Description
gponOltSFOff .1.3.6.1.4.1.6296.0.0.249
Description
memoryOverThresholdTrap
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.25
Memory over HighThreshold trap when used memory size is over the given limit.
gponOltSDOn .1.3.6.1.4.1.6296.0.0.250
Description
gponOltSDOff .1.3.6.1.4.1.6296.0.0.251
Description
gponOltLCDGIOn .1.3.6.1.4.1.6296.0.0.252
Description
gponOltLCDGIOff .1.3.6.1.4.1.6296.0.0.253
Description
gponOltRDOn .1.3.6.1.4.1.6296.0.0.254
Description
gponOltRDOff .1.3.6.1.4.1.6296.0.0.255
Description
gponOltSUFOn .1.3.6.1.4.1.6296.0.0.256
Description
gponOltSUFOff .1.3.6.1.4.1.6296.0.0.257
Description
gponOltLOAOn .1.3.6.1.4.1.6296.0.0.258
Description
gponOltLOAOff .1.3.6.1.4.1.6296.0.0.259
Description
memoryFallThresholdTrap
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.26
Memory fall under HighThreshold trap when used memory size fall under the given limit.
gponOltLOAMIOn .1.3.6.1.4.1.6296.0.0.260
Description
gponOltLOAMIOff .1.3.6.1.4.1.6296.0.0.261
Description
gponOltMEMOn .1.3.6.1.4.1.6296.0.0.262
Description
gponOltMEMOff .1.3.6.1.4.1.6296.0.0.263
Description
gponOltPEEOn .1.3.6.1.4.1.6296.0.0.264
Description
gponOltPEEOff .1.3.6.1.4.1.6296.0.0.265
Description
gponOltPSTOn .1.3.6.1.4.1.6296.0.0.266
Description
gponOltPSTOff .1.3.6.1.4.1.6296.0.0.267
Description
gponOltERROn .1.3.6.1.4.1.6296.0.0.268
Description
gponOltERROff .1.3.6.1.4.1.6296.0.0.269
Description
slotInstalledTrap
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.27
slotInstalledTrap Trap is sent when Board was installed.
gponOltREIOn .1.3.6.1.4.1.6296.0.0.270
Description
gponOltREIOff .1.3.6.1.4.1.6296.0.0.271
Description
slotRemovedTrap
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.28
slotRemovedTrap Trap is sent when Board was removed.
slotStateChangeTrap
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.29
slotStateChangeTrap Trap is sent when Board State change.
powerOkTrap
DASAN-SWITCH-MIBdsPowerIndex DASAN-SWITCH-MIBdsPowerstatus
.1.3.6.1.4.1.6296.0.0.3
Power status OK trap when powerStatus change from disable to enable.
portCRCOverThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.30
CRC Load over HighThreshold trap when crcLoad is over the given limit.
portCRCFallThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.31
CRC Load fall under HighThreshold trap when crcLoad fall under the given limit.
temperatureHighOverThreshold
DASAN-SWITCH-MIBdsTemperatureStatus
.1.3.6.1.4.1.6296.0.0.32
The temperatureHighOverThreshold Trap is sent when temperature is over the high-threshold.
temperatureHighFallThreshold
DASAN-SWITCH-MIBdsTemperatureStatus
.1.3.6.1.4.1.6296.0.0.33
The temperatureHighFallThreshold Trap is sent when temperature fall the high-threshold.
temperatureLowOverThreshold
DASAN-SWITCH-MIBdsTemperatureStatus
.1.3.6.1.4.1.6296.0.0.34
The temperatureLowOverThreshold Trap is sent when 1st temperature is over the low-threshold.
temperatureLowFallThreshold
DASAN-SWITCH-MIBdsTemperatureStatus
.1.3.6.1.4.1.6296.0.0.35
The temperatureLowFallThreshold Trap is sent when temperature fall under the low-threshold.
userLogIn
DASAN-USER-MANAGEMENT-MIBdsUserLoginName DASAN-USER-MANAGEMENT-MIBdsUserLoginIpAddress
.1.3.6.1.4.1.6296.0.0.36
The user-login trap is sent when user login.
userLogOut
DASAN-USER-MANAGEMENT-MIBdsUserLoginName DASAN-USER-MANAGEMENT-MIBdsUserLoginIpAddress
.1.3.6.1.4.1.6296.0.0.37
The user-logout trap is sent when user logout.
restoreFactory
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.38
The restoreFactory trap is sent when user initialize as factory defaults.
cpuLoadHighOverThreshold
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.39
The cpuloadHighOverThreshold Trap is sent when cpuload is over the high-threshold.
powerFailTrap
DASAN-SWITCH-MIBdsPowerIndex DASAN-SWITCH-MIBdsPowerstatus
.1.3.6.1.4.1.6296.0.0.4
Power status fail trap when powerStatus change from enable to disable.
cpuLoadHighFallThreshold
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.40
The cpuloadHighFallThreshold Trap is sent when cpuload fall the high-threshold.
cpuLoadLowOverThreshold
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.41
The cpuloadLowOverThreshold Trap is sent when 1st cpuload is over the low-threshold.
cpuLoadLowFallThreshold
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.42
The cpuloadLowFallThreshold Trap is sent when cpuload fall under the low-threshold.
igmpSnoopingChanged .1.3.6.1.4.1.6296.0.0.43
dsSystemUpgradeChanged
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.44
System NOS Upgrade status
fanOkTrap
DASAN-SWITCH-MIBdsFanIndex DASAN-SWITCH-MIBdsFanstatus
.1.3.6.1.4.1.6296.0.0.5
Fan status OK trap when fanStatus change from disable to enable.
adslAtucPerfLofsThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.51
Loss of Framing threshold reached(ATUC)
adslAtucPerfLossThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.52
Loss of signal threshold reached(ATUC)
adslAtucPerfLprsThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.53
Loss of power threshold reached (ATUC)
adslAtucPerfESsThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.54
Errored Seconds threshold reached (ATUC)
adslAtucRateChangeTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.55
Changed atuc rate
adslAtucPerfLolsThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.56
Loss of Link threshold reached (ATUC)
fanFailTrap
DASAN-SWITCH-MIBdsFanIndex DASAN-SWITCH-MIBdsFanstatus
.1.3.6.1.4.1.6296.0.0.6
Fan status fail trap when fanStatus change from enable to disable.
adslAturPerfLofsThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.61
Loss of Framing threshold reached(ATUR)
adslAturPerfLossThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.62
Loss of signal threshold reached(ATUR)
adslAturPerfLprsThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.63
Loss of power threshold reached (ATUR)
adslAturPerfESsThreshTrap
SNMPv2-MIBsysUpTime
.1.3.6.1.4.1.6296.0.0.64
Errored Seconds threshold reached (ATUR)
vdslCPEChangeInfoTrap
SNMPv2-MIBsysDescr ipAdEntAddr dsVdslPortIndex vdslPhysInvSerialNumber DASAN-SWITCH-MIBdsUserMacAddress1 DASAN-SWITCH-MIBdsUserMacAddress2 DASAN-SWITCH-MIBdsUserMacAddress3 DASAN-SWITCH-MIBdsUserMacAddress4
.1.3.6.1.4.1.6296.0.0.65
Trap is sent with CPE Serial No., Mac Address of CPE, after CPE serial change.
powerInstalledTrap
DASAN-SWITCH-MIBdsPowerIndex
.1.3.6.1.4.1.6296.0.0.7
Power Installed trap when power was installed.
cfgdBlocked
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.71
Cfgdblocked Trap is sent when a certain port is blocked by cpu-flood-guard mechanism.
cfgdReleased
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.72
CfgdReleased Trap is sent when a certain port is non-blocked by cpu-flood-guard mechanism.
cfgdOverThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.73
CfgdOverThreshold Trap is sent when a certain port is over the threshold by cpu-flood-guard mechanism.
cfgdUnderThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.74
CfgdUnderThreshold Trap is sent when a certain port fall under the threshold by cpu-flood-guard mechanism
sfgdBlocked
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.75
Sfgdblocked Trap is sent when a certain port is blocked by system-flood-guard mechanism.
sfgdReleased
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.76
SfgdReleased Trap is sent when a certain port is non-blocked by system-flood-guard mechanism.
sfgdOverThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.77
SfgdOverThreshold Trap is sent when a certain port is over the threshold by system-flood-guard mechanism.
sfgdUnderThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.78
SfgdUnderThreshold Trap is sent when a certain port fall under the threshold by system-flood-guard mechanism
ppsControlBlocked
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.79
ppsControlBlocked Trap is sent when a certain port is blocked by PPS-Control mechanism.
powerRemovedTrap
DASAN-SWITCH-MIBdsPowerIndex
.1.3.6.1.4.1.6296.0.0.8
Power removed trap when power was removed.
ppsControlReleased
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.80
ppsControlReleased Trap is sent when a certain port is non-blocked by PPS-Control mechanism.
ppsControlOverThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.81
ppsControlOverThreshold Trap is sent when a certain port is over the threshold by PPS-Control mechanism.
ppsontrolUnderThreshold
IF-MIBifIndex
.1.3.6.1.4.1.6296.0.0.82
ppsControlUnderThreshold Trap is sent when a certain port fall under the threshold by PPS-Control mechanism
nosRemoteUpgradeRequest
SNMPv2-MIBsysDescr DASAN-SWITCH-MIBdsSystemUpgradePath DASAN-SWITCH-MIBdsSystemUpgradeStorage
.1.3.6.1.4.1.6296.0.0.83
This trap indicates that the system received nos-remote-upgrade command.
nosRemoteUpgradeSuccess
SNMPv2-MIBsysDescr DASAN-SWITCH-MIBdsSystemUpgradePath DASAN-SWITCH-MIBdsSystemUpgradeStorage
.1.3.6.1.4.1.6296.0.0.84
This trap indicates that the NOS succeeded to upgrade NOS.
nosRemoteUpgradeFailAbort
SNMPv2-MIBsysDescr DASAN-SWITCH-MIBdsSystemUpgradePath DASAN-SWITCH-MIBdsSystemUpgradeStorage
.1.3.6.1.4.1.6296.0.0.85
This trap indicates that the system failed to download NOS by user interrup.
nosRemoteUpgradeFailHeaderError
SNMPv2-MIBsysDescr DASAN-SWITCH-MIBdsSystemUpgradePath DASAN-SWITCH-MIBdsSystemUpgradeStorage
.1.3.6.1.4.1.6296.0.0.86
This trap indicates that the system failed to download NOS, for NOS header-error.
nosRemoteUpgradeFailDownloadError
SNMPv2-MIBsysDescr DASAN-SWITCH-MIBdsSystemUpgradePath DASAN-SWITCH-MIBdsSystemUpgradeStorage
.1.3.6.1.4.1.6296.0.0.87
This trap indicates that the system failed to download NOS, for NOS checksum-error.
nosRemoteUpgradeFailFlashError
SNMPv2-MIBsysDescr DASAN-SWITCH-MIBdsSystemUpgradePath DASAN-SWITCH-MIBdsSystemUpgradeStorage
.1.3.6.1.4.1.6296.0.0.88
This trap indicates that the system failed to download NOS, for flash operation.
nosRemoteUpgradeStart
SNMPv2-MIBsysDescr DASAN-SWITCH-MIBdsSystemUpgradePath DASAN-SWITCH-MIBdsSystemUpgradeStorage
.1.3.6.1.4.1.6296.0.0.89
This trap indicates that the upgrade NOS process was started.
fanInstalledTrap
DASAN-SWITCH-MIBdsFanIndex
.1.3.6.1.4.1.6296.0.0.9
Fan Installed trap when fan was installed.
systemDyingGasp
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.90
This trap indicates that Dying-gasp for power fault.
attackGuardBlock
DASAN-SWITCH-MIBdsPortModuleIndex DASAN-SWITCH-MIBdsPortPortIndex
.1.3.6.1.4.1.6296.0.0.91
This trap indicates that some port is blocked by attack-guard.
attackGuardUnBlock
DASAN-SWITCH-MIBdsPortModuleIndex DASAN-SWITCH-MIBdsPortPortIndex
.1.3.6.1.4.1.6296.0.0.92
This trap indicates that some port is unblocked by attack-guard.
fanPeriodicFault
DASAN-SWITCH-MIBdsFanIndex DASAN-SWITCH-MIBdsFanstatus
.1.3.6.1.4.1.6296.0.0.93
This trap indicates the fan status is fault in some period.
remoteOamDyingGasp .1.3.6.1.4.1.6296.0.0.94
This trap indicates the remote oam entity is in dying-gasp.
remoteOamDyingGaspRestoration .1.3.6.1.4.1.6296.0.0.95
This trap indicates the remote oam entity is restored.
arpInspectInvalid .1.3.6.1.4.1.6296.0.0.96
This trap indicates the ARP inspection is invalided.
systemSwitchover
SNMPv2-MIBsysDescr
.1.3.6.1.4.1.6296.0.0.97
This trap indicates the system is switchover.
boardChangeState .1.3.6.1.4.1.6296.0.0.98
This trap indicates the board state is changed.