DAMOCLES-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
32
.1.3.6.1.4.1.21796.3.4.1
·
1 row entry
·
6 columns
A list of binary input entries.
An entry containing information applicable
to a particular binary input.
to a particular binary input.
Indexes
inpIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
inpIndex
mandatory
The binary input index.
|
PositiveInteger Textual Convention: PositiveInteger Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.21796.3.4.1.1.1 |
||||||
|
inpValue
mandatory
The binary input value.
|
OnOff Textual Convention: OnOff EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.1.1.2 |
||||||
|
inpName
mandatory
The binary input name.
|
IONamer/w Textual Convention: IOName OctetStringType Constraints: range: 0..20 |
.1.3.6.1.4.1.21796.3.4.1.1.3 |
||||||
|
inpAlarmSetup
mandatory
You can enable alarm for this binary input.
Alarm can be inactive or active for On/Off state. |
InputAlarmSetupr/w Textual Convention: InputAlarmSetup EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.1.1.4 |
||||||
|
inpAlarmState
mandatory
The binary input alarm state.
|
InputAlarmState Textual Convention: InputAlarmState EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.1.1.5 |
||||||
|
inpCounter
mandatory
Number of pulses on this input.
Entering edge is used to increment this counter. Only pulses longer than sampling interval are counted. |
NonNegativeIntegerr/w Textual Convention: NonNegativeInteger Integer32Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.21796.3.4.1.1.6 |
.1.3.6.1.4.1.21796.3.4.2
·
1 row entry
·
6 columns
A list of binary output entries.
An entry containing information applicable
to a particular binary output.
to a particular binary output.
Indexes
outIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
outIndex
mandatory
The binary output index.
|
PositiveInteger Textual Convention: PositiveInteger Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.21796.3.4.2.1.1 |
||||||||||
|
outValue
mandatory
The binary output value. 0 off(open), 1 on(close)
|
OnOffr/w Textual Convention: OnOff EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.2.1.2 |
||||||||||
|
outName
mandatory
The binary output name.
|
IONamer/w Textual Convention: IOName OctetStringType Constraints: range: 0..20 |
.1.3.6.1.4.1.21796.3.4.2.1.3 |
||||||||||
|
outType
mandatory
The binary output type. 0 relay (off, on), 1 rts (-10,+10V), 2 dtr (0,10V)
|
OutputType Textual Convention: OutputType EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.2.1.4 |
||||||||||
|
outMode
mandatory
The binary output mode. 0 manual, 1 autoAlarm,
2 autoTriggerEq, 3 autoTriggerHi, 4 autoTriggerLo |
OutputModer/w Textual Convention: OutputMode EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.2.1.5 |
||||||||||
|
outInit
mandatory
The binary output value after power-up. 0 off(open), 1 on(close)
|
OnOffr/w Textual Convention: OnOff EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.2.1.6 |
.1.3.6.1.4.1.21796.3.4.3
·
1 row entry
·
9 columns
A list of sensor table entries. The number of entries corresponds with number of detected sensors.
An entry containing information applicable to a
particular sensor.
particular sensor.
Indexes
sensIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sensIndex
mandatory
The sensor index.
|
PositiveInteger Textual Convention: PositiveInteger Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.21796.3.4.3.1.1 |
||||||||||||||||||||||||||
|
sensName
mandatory
The sensor name.
|
SensorName Textual Convention: SensorName OctetStringType Constraints: range: 0..15 |
.1.3.6.1.4.1.21796.3.4.3.1.2 |
||||||||||||||||||||||||||
|
sensState
mandatory
The sensor state.
|
SensorState Textual Convention: SensorState EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.3.1.4 |
||||||||||||||||||||||||||
|
sensString
mandatory
The string representation of sensor value.
|
SensorString Textual Convention: SensorString OctetStringType Constraints: range: 0..10 |
.1.3.6.1.4.1.21796.3.4.3.1.5 |
||||||||||||||||||||||||||
|
sensValue
mandatory
The integer (decimal * 10) representation
of sensor value. |
SensorValue Textual Convention: SensorValue Integer32 |
.1.3.6.1.4.1.21796.3.4.3.1.6 |
||||||||||||||||||||||||||
|
sensValueRaw
mandatory
The original raw value of sensor
(it differs for each sensor type, especially 1-Wire sensors have different precisions). |
SensorValue Textual Convention: SensorValue Integer32 |
.1.3.6.1.4.1.21796.3.4.3.1.7 |
||||||||||||||||||||||||||
|
sensID
mandatory
The sensor ID.
|
SensorID Textual Convention: SensorID Integer32Type Constraints: range: 0..65535 |
.1.3.6.1.4.1.21796.3.4.3.1.8 |
||||||||||||||||||||||||||
|
sensUnit
mandatory
The sensor unit.
|
UnitType Textual Convention: UnitType EnumerationType Values:
|
.1.3.6.1.4.1.21796.3.4.3.1.9 |
||||||||||||||||||||||||||
|
sensUnitString
mandatory
The string representation of sensor unit.
|
SensorUnitString Textual Convention: SensorUnitString OctetStringType Constraints: range: 0..4 |
.1.3.6.1.4.1.21796.3.4.3.1.10 |
.1.3.6.1.4.1.21796.3.4.50.2
·
1 row entry
·
5 columns
A list of alarm table entries. The table contains
zero, one, or many rows at any moment, depending upon
the number of alarm conditions in effect. The table
is initially empty at agent startup. The agent
creates a row in the table each time a condition is
detected and deletes that row when that condition no
longer pertains. The agent creates the first row with
tsAlarmId equal to 1, and increments the value of
tsAlarmId each time a new row is created, wrapping to
the first free value greater than or equal to 1 when
the maximum value of tsAlarmId would otherwise be
exceeded. Consequently, after multiple operations,
the table may become sparse, e.g., containing entries
for rows 95, 100, 101, and 203 and the entries should
not be assumed to be in chronological order because
tsAlarmId might have wrapped.
The number of rows in the table at any given time is
reflected by the value of tsAlarmsPresent.
An entry containing information applicable
to a particular alarm.
to a particular alarm.
Indexes
tsAlarmIdx
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
tsAlarmIdx
mandatory
An index to alarm table.
|
PositiveInteger Textual Convention: PositiveInteger Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.21796.3.4.50.2.1.1 |
||||
|
tsAlarmId
mandatory
A unique identifier for an alarm condition.
This value must remain constant. |
PositiveInteger Textual Convention: PositiveInteger Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.21796.3.4.50.2.1.2 |
||||
|
tsAlarmDescr
mandatory
Description of the alarm condition.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.21796.3.4.50.2.1.3 |
||||
|
tsAlarmSensName
mandatory
Name of sensor with alarm condition.
|
SensorName Textual Convention: SensorName OctetStringType Constraints: range: 0..15 |
.1.3.6.1.4.1.21796.3.4.50.2.1.4 |
||||
|
tsAlarmTime
mandatory
The value of sysUpTime when the alarm condition was
detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of tsAlarmTime shall equal 0. |
TimeStamp Textual Convention: TimeStamp Unsigned32 |
.1.3.6.1.4.1.21796.3.4.50.2.1.5 |
.1.3.6.1.4.1.21796.3.4.99.1.2
·
1 row entry
·
6 columns
A list of sensor table setup entries. The number of entries corresponds with number of detected sensors.
An entry containing setup information
for a particular sensor.
for a particular sensor.
Indexes
sensSetupIndex
| Column | Syntax | OID |
|---|---|---|
|
sensSetupIndex
mandatory
The sensor setup table index.
|
PositiveInteger Textual Convention: PositiveInteger Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.21796.3.4.99.1.2.1.1 |
|
sensSetupName
mandatory
The sensor name.
|
SensorNamer/w Textual Convention: SensorName OctetStringType Constraints: range: 0..15 |
.1.3.6.1.4.1.21796.3.4.99.1.2.1.2 |
|
sensFlags
mandatory
The behaviour of sensor
- 0x01: range or level detection - 0x02: enable trap sending -- 0x04: output set (thermostat) - 0x08: sensor enabled - 0x10: enable SMS sending - 0x20: enable email sending. |
SensorFlagsr/w Textual Convention: SensorFlags Integer32 |
.1.3.6.1.4.1.21796.3.4.99.1.2.1.5 |
|
sensLimitMin
mandatory
The sensor low limit.
|
SensorValuer/w Textual Convention: SensorValue Integer32 |
.1.3.6.1.4.1.21796.3.4.99.1.2.1.6 |
|
sensLimitMax
mandatory
The sensor high limit.
|
SensorValuer/w Textual Convention: SensorValue Integer32 |
.1.3.6.1.4.1.21796.3.4.99.1.2.1.7 |
|
sensHysteresis
mandatory
The sensor hysteresis.
|
SensorValuer/w Textual Convention: SensorValue Integer32 |
.1.3.6.1.4.1.21796.3.4.99.1.2.1.8 |