CTTRAPLOG-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
27

configTable

table mandatory
.1.3.6.1.4.1.52.4.1.44.2 · 1 row entry · 7 columns
configTableEntry entry .1.3.6.1.4.1.52.4.1.44.2.1
Each entry allows a user to configure the alarm table
for a specific slot. Objects such as Current Entry,
MaxEntries Allowed, and an Enable/Disable switch are
available.
Indexes
slotInChassis
Column Syntax OID
slotInChassis mandatory
Each Slot can be separately configured. This is the
slot number for the configuration entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.1
numEntriesLoggeds mandatory
This is the total number of entries looged for this
slot.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.2.1.2
numEntriesRequested mandatory
Maximum number of entries to store before wrapping
the log on this slot.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.3
numEntriesAllocated mandatory
This is the number of entries allocated to log alarms
on this slot. It will always be less than or equal
to the requested number of entries.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.4
lastLoggedEntryLogId mandatory
This is the log id of the last entry logged for this
slot.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.5
logCommand mandatory
Allows the user to send the log the commands
specified in the enumeration.
Enumerationr/w
Enumerated Values:
1clearLog
.1.3.6.1.4.1.52.4.1.44.2.1.6
wrap mandatory
This is whether or not this configuration has
wrapped or not.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.7

trapLogTable

table mandatory
.1.3.6.1.4.1.52.4.1.44.3 · 1 row entry · 10 columns
trapLogEntry entry .1.3.6.1.4.1.52.4.1.44.3.1
Each alarm entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply.
Indexes
slotChassis logId
Column Syntax OID
logId mandatory
Each slot has a maximium number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number
of entries for a slot is reached, the log wraps. Each
new en…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.1
nvmpId mandatory
This contains the nvmp id of the trap that occurred.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.2
trapLogAcknowledged mandatory
This field is set to 2 if a trap as been acknowledged
from the EM.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.3
trapLogVarBind mandatory
This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap.
OctetString
Constraints:
range: 0-1500
.1.3.6.1.4.1.52.4.1.44.3.1.4
trapLogDescription mandatory
This is an internally defined string used to describe
an alarm. Its primary use is for display on the EMs
LCD. A default value will be used for the old trap
calls.
OctetString
Constraints:
range: 0-80
.1.3.6.1.4.1.52.4.1.44.3.1.5
timeLogged mandatory
The time the entry was logged. This will be date and
time if possible.
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.3.1.6
filterId mandatory
This will be used to filter certain alarms. The
criteria is TBD. An example of classification:
informational - requires no intervention. warning -
Does not require immediate intervention. e.g. static
risk severe - Requi…
Enumeration
Enumerated Values:
1informational
2warning
3severe
4fatal
5existing
.1.3.6.1.4.1.52.4.1.44.3.1.7
slotChassis mandatory
Slot of this trap log.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.8
trapOID mandatory
This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.44.3.1.9
z80Time mandatory
This is the time that the Z80 has been up for the
board that sent this trap.
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.3.1.10

filterTable

table mandatory
.1.3.6.1.4.1.52.4.1.44.4 · 1 row entry · 10 columns
filterEntry entry .1.3.6.1.4.1.52.4.1.44.4.1
Each filter entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply.
Indexes
filterSlotInChassis filterFilterId filterLogId
Column Syntax OID
filterLogId mandatory
Each slot has a maximum number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number of
entries for a slot is reached, the log wraps. Each new
ent…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.1
filterNvmpId mandatory
This contains the nvmp id of the trap that was
generated.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.2
filterTrapLogAcknowledged mandatory
This field is non-zero if a trap has been acknowleged
from the EM.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.3
filterTrapLogVarBind mandatory
This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap.
OctetString
Constraints:
range: 0-1500
.1.3.6.1.4.1.52.4.1.44.4.1.4
filterTrapLogDescription mandatory
This is an internally defined string used to
describe an alarm. It's primary use is for display
on the EMs LCD. A default value will be used for
the old trap calls.
OctetString
Constraints:
range: 0-80
.1.3.6.1.4.1.52.4.1.44.4.1.5
filterTimeLogged mandatory
The time the entry was logged. This will be date
and time if possible.
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.4.1.6
filterFilterId mandatory
This will be used tofilter certain alarms. The
criteria is TBD. An example of classification:
informational-requires no intervention. warning -
Does not require immediate intervention. e.g.
statis risk severe - Requir…
Enumeration
Enumerated Values:
1informational
2warning
3severe
4fatal
5existing
.1.3.6.1.4.1.52.4.1.44.4.1.7
filterSlotInChassis mandatory
Slot of this filter entry.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.8
filterTrapOID mandatory
This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.44.4.1.9
filterZ80Time mandatory
The number of time ticks that have passed since
this boards Z80 processor has been up.
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.4.1.10