CPQN54NN-MIB

Imported Objects
RFC-1212 OBJECT-TYPE
RFC-1215 TRAP-TYPE
RFC1155-SMI enterprises
RFC1213-MIB sysDescr sysUpTime
Objects (19)
compaq .1.3.6.1.4.1.232
cpqGigaSwitch .1.3.6.1.4.1.232.111
cpqGigaSwitchProd .1.3.6.1.4.1.232.111.1
cpqGigaSwitchId5422 .1.3.6.1.4.1.232.111.1.1
cpqGigaSwitchId5411 .1.3.6.1.4.1.232.111.1.2
cpqOids .1.3.6.1.4.1.232.111.2
cpqMauType .1.3.6.1.4.1.232.111.2.1
cpqMauType1000BaseSX .1.3.6.1.4.1.232.111.2.1.1
cpqMauType1000BaseLX .1.3.6.1.4.1.232.111.2.1.2
cpqMauType1000BaseCX .1.3.6.1.4.1.232.111.2.1.3
cpqMauType1000BaseSXFD .1.3.6.1.4.1.232.111.2.1.4
cpqMauType1000BaseLXFD .1.3.6.1.4.1.232.111.2.1.5
cpqMauType1000BaseCXFD .1.3.6.1.4.1.232.111.2.1.6
cpqGigaSwitchMib .1.3.6.1.4.1.232.111.3
cpqGigaSwitchSystem .1.3.6.1.4.1.232.111.3.1
cpqSaveConfiguration mandatory r/w Enumeration .1.3.6.1.4.1.232.111.3.1.3
cpqSaveStatus mandatory Enumeration .1.3.6.1.4.1.232.111.3.1.4
cpqCurrentConfigInUse mandatory Enumeration .1.3.6.1.4.1.232.111.3.1.5
cpqConfigToUseOnReboot mandatory r/w Enumeration .1.3.6.1.4.1.232.111.3.1.6
Notifications / Traps (8)
NameOIDDescription
powerSupplyFail
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.10
One or more sources of power to this agent has failed.
Presumably a redundant power-supply has taken over.
powerSupplyGood
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.11
One or more previously bad sources of power to this agent
has come back to life without causing an agent restart.
rpsAlarm
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.12
Attached Redundant Power Supply device is indicating
an alarm condition.
rpsNoAlarm
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.13
Attached Redundant Power Supply device is no longer
indicating an alarm condition.
overheat
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.6
A overheat trap indicates that the on board
tempature sensor has reported a overheat
condition.  System will shutdown until unit has
 sufficiently cooled such that operation may begin
again.  A cold start trap will be issued when
the unit has come back on line.
fanfailed
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.7
A fan failed trap indicates one or more of the
cooling fans inside the device has failed.  A
fanOK trap will be sent once the fan has attained
normal operation.
fanOK
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.8
A fan has transitioned out of a failure state and
is now operating correctly.
invalidLoginAttempt
RFC1213-MIBsysUpTime RFC1213-MIBsysDescr
.1.3.6.1.4.1.232.111.0.9
A user attempted to login to console or by telnet but was refused
access due to incorrect username or password