CISCO-WAN-BBIF-PORT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
29
.1.3.6.1.4.1.351.110.5.2.6.1.1.1 · 1 row entry · 10 columns
The Broadband Interface config table is for logical interface.
There will an entry for each of the logical partition of the 
physical line.
bbIfCnfPortGrpEntry entry .1.3.6.1.4.1.351.110.5.2.6.1.1.1.1
An entry for the logical interface. The interface may be further
be configured to be used as a virtual trunk OR as a UNI Port.
Indexes
bbIfNum
Column Syntax OID
bbIfNum
This is logical interface number within a physical line num.
In MGX PXM1 card, a physical port can have a maximum of 32 logical
interfaces.
Integer32
Constraints:
range: 1-32
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.1
bbIfRowStatus
This variable enables or disables the logical interface.
1 - enable
2 - disable
3 - modify
Enumerationr/w
Enumerated Values:
1add
2del
3mod
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.2
bbIfAdmin
This variable enables or disables the logical interface.
1 - up
2 - down
3 - writeOnly
Enumerationr/w
Enumerated Values:
1up
2down
3writeOnly
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.3
bbIfLineNum
The line number associated with the logical interface.
For PXM1, there is currently 4 physical lines.
Integer32r/w
Constraints:
range: 1-4
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.4
bbIfIngrPctBandwidth
The percentage of aggregate physical line bandwidth, available for
this broadband interface - Ingress. Default is 0 %.
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.5
bbIfEgrPctBandwidth
The percentage of aggregate physical line bandwidth, available for
this broadband interface - Egress . Default is 0 %.
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.6
bbIfMinVpi
The lower limit of VPI range to be reserved for
this logical interface.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.7
bbIfMaxVpi
The upper limit of VPI range to be reserved
for this logical interface.

For virtual trunks, bbIfMinVpi and bbIfMaxVpi should
be the same.
Integer32r/w
Constraints:
range: 0-4095
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.8
bbIfSpeed
The speed of the port in cells per second.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.9
bbIfMaxCellRatePct
The maximum cell rate allowed for the port in terms of
percentage. Must be greater than or equal to
bbIfIngrPctBandwidth.
The default is 100 percent.
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.351.110.5.2.6.1.1.1.1.10
.1.3.6.1.4.1.351.110.5.2.6.3.1 · 1 row entry · 5 columns
The state table for the logical  interface.
bbIfStateGrpEntry entry .1.3.6.1.4.1.351.110.5.2.6.3.1.1
An entry for each logical interface representing
the state.
Indexes
bbStateIfNum
Column Syntax OID
bbStateIfNum
This is logical interface number within a physical line num.
In MGX PXM1 card, a physical port can have a maximum of
32 logical interfaces.
Integer32
Constraints:
range: 1-32
.1.3.6.1.4.1.351.110.5.2.6.3.1.1.1
bbIfState
This variable indicates the status of the logical interface.

The following values are not supported for the logical interface.

remoteloopback (3),
outofcelldelineation (6),
localloopb…
Enumeration
Enumerated Values:
1notConfigured
2active
4linefailure
5signallingfailure
6inactive
7lineinloopback
.1.3.6.1.4.1.351.110.5.2.6.3.1.1.2
bbIfOversubscribed
This variable indicates the whether the logical interface is
over subscribed or not.
Enumeration
Enumerated Values:
1false
2true
.1.3.6.1.4.1.351.110.5.2.6.3.1.1.3
bbIfIngrPercentUtil
Percentage Utilization of the interface in the
Ingress direction.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.351.110.5.2.6.3.1.1.4
bbIfEgrPercentUtil
Percentage Utilization of the interface in
the Egress direction.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.351.110.5.2.6.3.1.1.5
.1.3.6.1.4.1.351.110.5.2.6.4.1.1 · 1 row entry · 14 columns
The Broadband Interface Count table is for logical interface.
There will an entry for each of the logical partition of the
physical line.
bbIfCntGrpEntry entry .1.3.6.1.4.1.351.110.5.2.6.4.1.1.1
An entry for logical interface.
Indexes
bbCntIfNum
Column Syntax OID
bbCntIfNum
Refers to the logical interface index.
Integer32
Constraints:
range: 1-32
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.1
bbIfTotalCells
Total number of cells (VC plus Qbin) that belong
to this Interface. This maps on to the virtual interface of QE.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.2
bbIfRcvValidOAMCells
Total number of OAM cell received.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.3
bbIfRcvRmCells
Total number of RM cells Received.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.4
bbIfRcvClp0Cells
Total number of CLP-0 cells Received.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.5
bbIfRcvClp1Cells
Total number of CLP-1 cells Received.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.6
bbIfRcvClp0DiscCells
Total number of CLP-0 cells discarded at Ingress.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.7
bbIfRcvClp1DiscCells
Total number of CLP-1 cells discarded at Ingress.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.8
bbIfXmtOAMCells
Total number of OAM cells transmitted.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.9
bbIfXmtRmCells
Total number of RM cells transmitted.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.10
bbIfXmtClp0Cells
Total number of CLP-0 cells transmitted.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.11
bbIfXmtClp1Cells
Total number of CLP-1 cells transmitted.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.12
bbIfCntClrButton
Writing a value of 2 resets all the counters.
Enumerationr/w
Enumerated Values:
1noAction
2resetCounter32s
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.13
bbIfRcvErroredCells
Total number of cells with Invalid VPI VCI or
Invalid PTI fields This is a card level counter and
hence will be the same for all instances of the ports.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.351.110.5.2.6.4.1.1.1.14