CISCO-FLOW-MONITOR-TC-MIB
This MIB module defines textual conventions used by the MIB
modules defining objects describing flow monitoring.
GLOSSARY
============
Alarm Action - a method used by the device to signal changes in
an alarm condition.
Alarm Aggregation - a technique used to efficiently monitor the
same standing condition for a flow set.
Alarm Condition - a standing condition for which the device
signals changes in state.
Alarm Group - a flow set for which the device monitors a
configured standing condition, raising an alarm when a
configured number of flows in the flow set assert the
standing standing.
Alarm Severity - the relative disposition of an alarm condition
when raised by the device. For example, a provider may
regard a flow stop alarm as having a higher severity than a
flow's loss fraction exceeding a configured threshold.
Flow Monitor - a hardware or software entity that classifies
traffic flows, collects flow data, and periodically
computes flow metrics.
Flow Metric - a measurement that reflects the quality of a
traffic flow.
Flow Point - represents the ingress or egress of a traffic flow.
Flow Set - a group of traffic flows.
Measurement Interval - the length of time over which a flow
monitor collects data related to a traffic flow, after which
the flow monitor computes flow metrics using the collected
data.
Standing Condition - represents a lasting error, fault, or
warning resulting from the application of a set of criteria
to the state of an entity, such as a flow monitor or traffic
flow. For example, a flow monitor may assert a standing
condition if the number of traffic flows that expire in a
meansurement interval exceeds a configured threshold.
Traffic Flow - a unidirectional stream of packets conforming to
a classifier. For example, packets having a particular
source IP address, destination IP address, protocol type,
source port number, and destination port number.
ciscoFlowMonitorTcMIB
1.3.6.1.4.1.9.9.688
Imported Objects
| CISCO-SMI | ciscoMgmt |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION |
Type Definitions (18)
| FlowBitRateUnits | Enumeration |
bps(1)kbps(2)mbps(3)gbps(4) |
| FlowCfgRateType | Enumeration |
auto(1)ipPktRate(2)ipBitRate(3)mediaRate(4) |
| FlowIdentifier | Unsigned32 |
range: 1..4294967295 |
| FlowMetricPrecision | Integer32 |
range: -8..-1range: 1..9 |
| FlowMetrics | Bits |
mdi(0)rtp(1)ipCbr(2) |
| FlowMetricScale | Enumeration |
yocto(1)zepto(2)atto(3)femto(4)pico(5)nano(6)micro(7)milli(8)units(9)kilo(10)mega(11)giga(12)tera(13)exa(14)peta(15)zetta(16)yotta(17) |
| FlowMetricValue | Integer32 |
range: -1000000000..1000000000 |
| FlowMonitorAlarmGroupIdentifier | Unsigned32 |
range: 1..4294967295 |
| FlowMonitorConditionIdentifier | Unsigned32 |
range: 0..2039 |
| FlowMonitorConditions | OctetString |
range: 0..255 |
| FlowMonitorConditionsProfile | Unsigned32 |
range: 1..4294967295 |
| FlowMonitorConditionsProfileOrZero | Unsigned32 |
range: 0..4294967295 |
| FlowMonitorIdentifier | Unsigned32 |
range: 1..4294967295 |
| FlowPointDot1qVlan | OctetString |
range: 6 |
| FlowPointIdentifier | OctetString |
range: 0..255 |
| FlowPointInterface | OctetString |
range: 4 |
| FlowPointType | Enumeration |
other(1)unknown(2)none(3)interface(4)dot1qVlan(5) |
| FlowSetIdentifier | Unsigned32 |
range: 1..4294967295 |
Objects (1)
|
|
.1.3.6.1.4.1.9.9.688 |