CISCO-FLOW-MONITOR-TC-MIB

        This MIB module defines textual conventions used by the MIB
modules defining objects describing flow monitoring.
        
GLOSSARY
============
        
Alarm Action - a method used by the device to signal changes in
    an alarm condition.
        
Alarm Aggregation - a technique used to efficiently monitor the
    same standing condition for a flow set.
        
Alarm Condition - a standing condition for which the device
    signals changes in state.
        
Alarm Group - a flow set for which the device monitors a
    configured standing condition, raising an alarm when a
    configured number of flows in the flow set assert the
    standing standing.
        
Alarm Severity - the relative disposition of an alarm condition
    when raised by the device.  For example, a provider may
    regard a flow stop alarm as having a higher severity than a
    flow's loss fraction exceeding a configured threshold.
        
Flow Monitor - a hardware or software entity that classifies
    traffic flows, collects flow data, and periodically
    computes flow metrics.
        
Flow Metric - a measurement that reflects the quality of a
    traffic flow.
        
Flow Point - represents the ingress or egress of a traffic flow.
        
Flow Set - a group of traffic flows.
        
Measurement Interval - the length of time over which a flow
    monitor collects data related to a traffic flow, after which
    the flow monitor computes flow metrics using the collected
    data.
        
Standing Condition - represents a lasting error, fault, or
    warning resulting from the application of a set of criteria
    to the state of an entity, such as a flow monitor or traffic
    flow.  For example, a flow monitor may assert a standing
    condition if the number of traffic flows that expire in a
    meansurement interval exceeds a configured threshold.
        
Traffic Flow - a unidirectional stream of packets conforming to
    a classifier.  For example, packets having a particular 
    source IP address, destination IP address, protocol type,
    source port number, and destination port number.
    
ciscoFlowMonitorTcMIB 1.3.6.1.4.1.9.9.688
Imported Objects
CISCO-SMI ciscoMgmt
SNMPv2-SMI Integer32 MODULE-IDENTITY Unsigned32
SNMPv2-TC TEXTUAL-CONVENTION
Type Definitions (18)
FlowBitRateUnits Enumeration
bps(1)
kbps(2)
mbps(3)
gbps(4)
FlowCfgRateType Enumeration
auto(1)
ipPktRate(2)
ipBitRate(3)
mediaRate(4)
FlowIdentifier Unsigned32 range: 1..4294967295
FlowMetricPrecision Integer32 range: -8..-1range: 1..9
FlowMetrics Bits
mdi(0)
rtp(1)
ipCbr(2)
FlowMetricScale Enumeration
yocto(1)
zepto(2)
atto(3)
femto(4)
pico(5)
nano(6)
micro(7)
milli(8)
units(9)
kilo(10)
mega(11)
giga(12)
tera(13)
exa(14)
peta(15)
zetta(16)
yotta(17)
FlowMetricValue Integer32 range: -1000000000..1000000000
FlowMonitorAlarmGroupIdentifier Unsigned32 range: 1..4294967295
FlowMonitorConditionIdentifier Unsigned32 range: 0..2039
FlowMonitorConditions OctetString range: 0..255
FlowMonitorConditionsProfile Unsigned32 range: 1..4294967295
FlowMonitorConditionsProfileOrZero Unsigned32 range: 0..4294967295
FlowMonitorIdentifier Unsigned32 range: 1..4294967295
FlowPointDot1qVlan OctetString range: 6
FlowPointIdentifier OctetString range: 0..255
FlowPointInterface OctetString range: 4
FlowPointType Enumeration
other(1)
unknown(2)
none(3)
interface(4)
dot1qVlan(5)
FlowSetIdentifier Unsigned32 range: 1..4294967295
Objects (1)
ciscoFlowMonitorTcMIB .1.3.6.1.4.1.9.9.688