CISCO-FIREPOWER-DIAG-MIB

        MIB representation of the Cisco Firepower
DIAG management information model package
    
cfprDiagObjects 1.3.6.1.4.1.9.9.826.1.16
Imported Objects
CISCO-FIREPOWER-MIB CfprManagedObjectDn CfprManagedObjectId ciscoFirepowerMIBObjects
CISCO-FIREPOWER-TC-MIB CfprDiagAdminState CfprDiagBladeTestType CfprDiagFailureAction CfprDiagNetworkTestType CfprDiagSrvCtrlType CfprDiagStatus CfprDiagStatusIssues CfprDiagSuccessAction CfprDiagTestOrder CfprNetworkSwitchId CfprPolicyPolicyOwner
CISCO-SMI ciscoMgmt
CISCO-TC CiscoAlarmSeverity CiscoInetAddressMask CiscoNetworkAddress TimeIntervalSec Unsigned64
INET-ADDRESS-MIB InetAddressIPv4 InetAddressIPv6
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-SMI Counter32 Counter64 Gauge32 MODULE-IDENTITY OBJECT-TYPE TimeTicks Unsigned32
SNMPv2-TC DateAndTime DisplayString MacAddress RowPointer TEXTUAL-CONVENTION TimeInterval TimeStamp TruthValue
Objects (75)
cfprDiagObjects .1.3.6.1.4.1.9.9.826.1.16
cfprDiagBladeTestTable .1.3.6.1.4.1.9.9.826.1.16.1
cfprDiagBladeTestEntry cfprDiagBladeTestInstanceId .1.3.6.1.4.1.9.9.826.1.16.1.1
cfprDiagBladeTestInstanceId CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.16.1.1.1
cfprDiagBladeTestDn CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.16.1.1.2
cfprDiagBladeTestRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.1.1.3
cfprDiagBladeTestLength SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.1.1.4
cfprDiagBladeTestOrder CISCO-FIREPOWER-TC-MIBCfprDiagTestOrder .1.3.6.1.4.1.9.9.826.1.16.1.1.5
cfprDiagBladeTestType CISCO-FIREPOWER-TC-MIBCfprDiagBladeTestType .1.3.6.1.4.1.9.9.826.1.16.1.1.6
cfprDiagNetworkTestTable .1.3.6.1.4.1.9.9.826.1.16.2
cfprDiagNetworkTestEntry cfprDiagNetworkTestInstanceId .1.3.6.1.4.1.9.9.826.1.16.2.1
cfprDiagNetworkTestInstanceId CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.16.2.1.1
cfprDiagNetworkTestDn CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.16.2.1.2
cfprDiagNetworkTestRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.2.1.3
cfprDiagNetworkTestLength SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.2.1.4
cfprDiagNetworkTestOrder CISCO-FIREPOWER-TC-MIBCfprDiagTestOrder .1.3.6.1.4.1.9.9.826.1.16.2.1.5
cfprDiagNetworkTestSwitchId CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId .1.3.6.1.4.1.9.9.826.1.16.2.1.6
cfprDiagNetworkTestType CISCO-FIREPOWER-TC-MIBCfprDiagNetworkTestType .1.3.6.1.4.1.9.9.826.1.16.2.1.7
cfprDiagRsltTable .1.3.6.1.4.1.9.9.826.1.16.3
cfprDiagRsltEntry cfprDiagRsltInstanceId .1.3.6.1.4.1.9.9.826.1.16.3.1
cfprDiagRsltInstanceId CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.16.3.1.1
cfprDiagRsltDn CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.16.3.1.2
cfprDiagRsltRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.3.1.3
cfprDiagRsltDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.3.1.4
cfprDiagRsltEndTs SNMPv2-TCDateAndTime .1.3.6.1.4.1.9.9.826.1.16.3.1.5
cfprDiagRsltId SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.3.1.6
cfprDiagRsltResult SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.3.1.7
cfprDiagRsltRsltStatus CISCO-FIREPOWER-TC-MIBCfprDiagStatus .1.3.6.1.4.1.9.9.826.1.16.3.1.8
cfprDiagRsltStartTs SNMPv2-TCDateAndTime .1.3.6.1.4.1.9.9.826.1.16.3.1.9
cfprDiagRunPolicyTable .1.3.6.1.4.1.9.9.826.1.16.4
cfprDiagRunPolicyEntry cfprDiagRunPolicyInstanceId .1.3.6.1.4.1.9.9.826.1.16.4.1
cfprDiagRunPolicyInstanceId CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.16.4.1.1
cfprDiagRunPolicySuccessAction CISCO-FIREPOWER-TC-MIBCfprDiagSuccessAction .1.3.6.1.4.1.9.9.826.1.16.4.1.10
cfprDiagRunPolicyDn CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.16.4.1.2
cfprDiagRunPolicyRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.4.1.3
cfprDiagRunPolicyDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.4.1.4
cfprDiagRunPolicyFailureAction CISCO-FIREPOWER-TC-MIBCfprDiagFailureAction .1.3.6.1.4.1.9.9.826.1.16.4.1.5
cfprDiagRunPolicyIntId SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.4.1.6
cfprDiagRunPolicyName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.4.1.7
cfprDiagRunPolicyPolicyLevel SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.4.1.8
cfprDiagRunPolicyPolicyOwner CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner .1.3.6.1.4.1.9.9.826.1.16.4.1.9
cfprDiagSrvCapProviderTable .1.3.6.1.4.1.9.9.826.1.16.5
cfprDiagSrvCapProviderEntry cfprDiagSrvCapProviderInstanceId .1.3.6.1.4.1.9.9.826.1.16.5.1
cfprDiagSrvCapProviderInstanceId CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.16.5.1.1
cfprDiagSrvCapProviderLoadWarnings SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.5.1.10
cfprDiagSrvCapProviderMgmtPlaneVer SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.5.1.11
cfprDiagSrvCapProviderModel SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.5.1.12
cfprDiagSrvCapProviderPromCardType SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.5.1.13
cfprDiagSrvCapProviderRevision SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.5.1.14
cfprDiagSrvCapProviderVendor SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.5.1.15
cfprDiagSrvCapProviderDn CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.16.5.1.2
cfprDiagSrvCapProviderRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.5.1.3
cfprDiagSrvCapProviderDeleted SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.826.1.16.5.1.4
cfprDiagSrvCapProviderDeprecated SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.826.1.16.5.1.5
cfprDiagSrvCapProviderElementLoadFailures SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.5.1.6
cfprDiagSrvCapProviderElementsLoaded SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.5.1.7
cfprDiagSrvCapProviderGencount SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.5.1.8
cfprDiagSrvCapProviderLoadErrors SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.826.1.16.5.1.9
cfprDiagSrvCtrlTable .1.3.6.1.4.1.9.9.826.1.16.6
cfprDiagSrvCtrlEntry cfprDiagSrvCtrlInstanceId .1.3.6.1.4.1.9.9.826.1.16.6.1
cfprDiagSrvCtrlInstanceId CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.16.6.1.1
cfprDiagSrvCtrlOperQualifier CISCO-FIREPOWER-TC-MIBCfprDiagStatusIssues .1.3.6.1.4.1.9.9.826.1.16.6.1.10
cfprDiagSrvCtrlOperState CISCO-FIREPOWER-TC-MIBCfprDiagStatus .1.3.6.1.4.1.9.9.826.1.16.6.1.11
cfprDiagSrvCtrlRunPolicyName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.6.1.12
cfprDiagSrvCtrlStartTs SNMPv2-TCDateAndTime .1.3.6.1.4.1.9.9.826.1.16.6.1.13
cfprDiagSrvCtrlStartTsM CISCO-TCUnsigned64 .1.3.6.1.4.1.9.9.826.1.16.6.1.14
cfprDiagSrvCtrlType CISCO-FIREPOWER-TC-MIBCfprDiagSrvCtrlType .1.3.6.1.4.1.9.9.826.1.16.6.1.15
cfprDiagSrvCtrlDn CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.16.6.1.2
cfprDiagSrvCtrlRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.6.1.3
cfprDiagSrvCtrlAdminState CISCO-FIREPOWER-TC-MIBCfprDiagAdminState .1.3.6.1.4.1.9.9.826.1.16.6.1.4
cfprDiagSrvCtrlEndTs SNMPv2-TCDateAndTime .1.3.6.1.4.1.9.9.826.1.16.6.1.5
cfprDiagSrvCtrlEndTsM CISCO-TCUnsigned64 .1.3.6.1.4.1.9.9.826.1.16.6.1.6
cfprDiagSrvCtrlErrorDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.6.1.7
cfprDiagSrvCtrlImgLoc SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.6.1.8
cfprDiagSrvCtrlImgName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.826.1.16.6.1.9