cePfePerfConfigTable
table.1.3.6.1.4.1.9.9.265.1.1.1
·
1 row entry
·
8 columns
This table contains configuration information on a PFE pipeline.
An entry will exist for each entry in the entPhysicalTable
that correspond to an active PFE pipeline.
that correspond to an active PFE pipeline.
Indexes
ENTITY-MIBentPhysicalIndex
| Column | Syntax | OID |
|---|---|---|
|
cePfePerfConfigTimeElapsed
The number of seconds that have elapsed since the beginning
of the current 15 min interval. If for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value,… |
secondsUnsigned32 Constraints: range: 0-899 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.1 |
|
cePfePerfConfigValidIntervals
The number of completed 15 min intervals for which valid
PFE performance data has been collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be … |
Unsigned32 Constraints: range: 0-96 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.2 |
|
cePfePerfConfigThldUtilization
This object contains the threshold value for the
cePfePerfCurrentUtilization object. If during the last 5 second measurement period the cePfePerfCurrentUtilization object becomes greater than or equal to this threshold… |
Percentager/w Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.3 |
|
cePfePerfConfigThldEfficiency
This object contains the threshold value for the
cePfePerfCurrentEffciency object. If during the last 5 second measurement period the cePfePerfCurrentEfficiency object becomes less than or equal to this threshold valu… |
Percentager/w Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.4 |
|
cePfePerfConfigThld1MinUtilization
This object contains the threshold value for the
cePfePerfCurrent1MinUtilization object. If during the last 1 minute measurement period the cePfePerfCurrent1MinUtilization object becomes greater than or equal to this t… |
Percentager/w Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.5 |
|
cePfePerfConfigThld1MinEfficiency
This object contains the threshold value for the
cePfePerfCurrent1MinEfficiency object. If during the last 1 minute measurement period the cePfePerfCurrent1MinEfficiency object becomes less than or equal to this thres… |
Percentager/w Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.6 |
|
cePfePerfConfigThld5MinUtilization
This object contains the threshold value for the
cePfePerfCurrent5MinUtilization object. If during the last 5 minute measurement period the cePfePerfCurrent5MinUtilization object becomes greater than or equal to this t… |
Percentager/w Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.7 |
|
cePfePerfConfigThld5MinEfficiency
This object contains the threshold value for the
cePfePerfCurrent5MinEfficiency object. If during the last 5 minute measurement period the cePfePerfCurrent5MinEfficiency object becomes less than or equal to this thres… |
Percentager/w Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.1.1.8 |
cePfePerfCurrentTable
table.1.3.6.1.4.1.9.9.265.1.1.2
·
1 row entry
·
6 columns
This table maintains PFE current running performance, which are collected at various measurement periods.
An entry containing performance information applicable to
a particular PFE pipeline.
a particular PFE pipeline.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
cePfePerfCurrentUtilization
This object provides the actual PFE percentage utilization.
It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline. |
CurrentUtilization Textual Convention: CurrentUtilization Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.2.1.1 |
|
cePfePerfCurrentEfficiency
This object provides the actual PFE percentage efficiency.
It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal co… |
CurrentEfficiency Textual Convention: CurrentEfficiency Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.2.1.2 |
|
cePfePerfCurrent1MinUtilization
This object provides the PFE percentage utilization over the
previous 1 minute period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported … |
CurrentUtilization Textual Convention: CurrentUtilization Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.2.1.3 |
|
cePfePerfCurrent1MinEfficiency
This object provides the PFE percentage efficiency over the
previous 1 minute period. It is determined by the totalnumber of contexts per second divided by maximum theoretical contexts per second supported by the PFE p… |
CurrentEfficiency Textual Convention: CurrentEfficiency Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.2.1.4 |
|
cePfePerfCurrent5MinUtilization
This object provides the PFE percentage utilization over the
previous 5 minutes period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supporte… |
CurrentUtilization Textual Convention: CurrentUtilization Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.2.1.5 |
|
cePfePerfCurrent5MinEfficiency
This object provides the PFE percentage efficiency over the
previous 5 minutes period. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PF… |
CurrentEfficiency Textual Convention: CurrentEfficiency Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.2.1.6 |
cePfePerfIntervalTable
table.1.3.6.1.4.1.9.9.265.1.1.3
·
1 row entry
·
3 columns
This table contains performance statistics for completed 15 minutes intervals, specifically up to 96 such intervals over a 24 hours of operation.
An entry containing performance information applicable to
a particular PFE pipeline at a specific interval.
a particular PFE pipeline at a specific interval.
Indexes
ENTITY-MIBentPhysicalIndex cePfePerfIntervalNumber
| Column | Syntax | OID |
|---|---|---|
|
cePfePerfIntervalNumber
An interval number between 1 and 96, where 1 is the most
recently completed 15 min interval and 96 is the 15 min interval completed 23 hours and 45 minutes prior to interval 1. |
Unsigned32 Constraints: range: 1-96 |
.1.3.6.1.4.1.9.9.265.1.1.3.1.1 |
|
cePfePerfIntervalUtilization
The percentage of processor utilization by the PFE pipeline
during this completed 15 min interval. |
IntervalUtilization Textual Convention: IntervalUtilization Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.3.1.2 |
|
cePfePerfIntervalEfficiency
The percentage of processor efficiency by the PFE pipeline
during this completed 15 min interval. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it … |
IntervalEfficiency Textual Convention: IntervalEfficiency Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.3.1.3 |
cePfePerfTotalTable
table.1.3.6.1.4.1.9.9.265.1.1.4
·
1 row entry
·
2 columns
This table contains the running utilization and efficiency of the PFE pipeline for the 24 hour period preceding the current interval. If the agent was restarted less than 24 hours ago, i.e., when there are less than 96 intervals in the cePfePerfIntervalTable, it will contain the running utiliza- tion and efficiency up to the last collected 15 minute inter- val.
An entry containing performance information applicable to
a particular PFE pipeline at the end of each interval in the
cePfePerfIntervalTable.
a particular PFE pipeline at the end of each interval in the
cePfePerfIntervalTable.
Indexes
ENTITY-MIBentPhysicalIndex
| Column | Syntax | OID |
|---|---|---|
|
cePfePerfTotalUtilization
The running utilization by the PFE pipeline for the prece-
ding 24 hrs. |
TotalUtilization Textual Convention: TotalUtilization Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.4.1.1 |
|
cePfePerfTotalEfficiency
The running efficiency by the PFE pipeline for the preceding
24 hrs. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero. |
TotalEfficiency Textual Convention: TotalEfficiency Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.1.4.1.2 |
cePfeHistTable
table.1.3.6.1.4.1.9.9.265.1.2.4
·
1 row entry
·
7 columns
This table contains a history of events generated by the agent.
An entry will exist for each event that has occured while
cePfeHistNotifiesEnable object is set to 'log(2)' or
'logAndNotify(4)'.
cePfeHistNotifiesEnable object is set to 'log(2)' or
'logAndNotify(4)'.
Indexes
cePfeHistIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cePfeHistIndex
An integer value uniquely identifying the entry in the table.
The value of this object starts at '1' and monotonically increases for each event condition transition monitored by the agent. If the value of this object … |
Unsigned32 Constraints: range: 1-4294967295 |
.1.3.6.1.4.1.9.9.265.1.2.4.1.1 |
||||||||||||||
|
cePfeHistEntPhysIndex
The value in this object is equal to the value of the
entPhysicalIndex, from the Physical Entity Table (RFC 2037), that is associated with the PFE pipeline that has caused this event. |
ENTITY-MIBPhysicalIndex Textual Convention: ENTITY-MIBPhysicalIndex Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.9.9.265.1.2.4.1.2 |
||||||||||||||
|
cePfeHistType
This object describes the type of event that has occurred.
|
HistEventType Textual Convention: HistEventType EnumerationType Values:
|
.1.3.6.1.4.1.9.9.265.1.2.4.1.3 |
||||||||||||||
|
cePfeHistThld
The configured value of the specific threshold.
|
Percentage Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.2.4.1.4 |
||||||||||||||
|
cePfeHistValue
The actual value of the specific performance objects, at the
time of the sample, which is related to the threshold event. |
Percentage Textual Convention: Percentage Unsigned32Type Constraints: range: 0..100 |
.1.3.6.1.4.1.9.9.265.1.2.4.1.5 |
||||||||||||||
|
cePfeHistRestartReason
The reason for which the PFE pipeline has restarted.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.265.1.2.4.1.6 |
||||||||||||||
|
cePfeHistTimeStamp
This object specifies the value of the sysUpTime object at
the time the event was generated. |
SNMPv2-TCTimeStamp Textual Convention: SNMPv2-TCTimeStamp Unsigned32 |