CISCO-ENTITY-PFE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
26
.1.3.6.1.4.1.9.9.265.1.1.1 · 1 row entry · 8 columns
This table contains configuration information on a PFE 
pipeline.
cePfePerfConfigEntry entry .1.3.6.1.4.1.9.9.265.1.1.1.1
An entry will exist for each entry in the entPhysicalTable
that correspond to an active PFE pipeline.
Indexes
ENTITY-MIBentPhysicalIndex
Column Syntax OID
cePfePerfConfigTimeElapsed
The number of seconds that have elapsed since the beginning
of the current 15 min interval. If for some reason, such as
an adjustment in the system's time-of-day clock, the current
interval exceeds the maximum value,…
secondsUnsigned32
Constraints:
range: 0-899
.1.3.6.1.4.1.9.9.265.1.1.1.1.1
cePfePerfConfigValidIntervals
The number of completed 15 min intervals for which valid
PFE performance data has been collected. The value
will be 96 unless the interface was brought online within the
last 24 hours, in which case the value will be …
Unsigned32
Constraints:
range: 0-96
.1.3.6.1.4.1.9.9.265.1.1.1.1.2
cePfePerfConfigThldUtilization
This object contains the threshold value for the
cePfePerfCurrentUtilization object. If during the last 5
second measurement period the cePfePerfCurrentUtilization
object becomes greater than or equal to this threshold…
Percentager/w
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.1.1.3
cePfePerfConfigThldEfficiency
This object contains the threshold value for the
cePfePerfCurrentEffciency object. If during the last 5
second measurement period the cePfePerfCurrentEfficiency
object becomes less than or equal to this threshold valu…
Percentager/w
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.1.1.4
cePfePerfConfigThld1MinUtilization
This object contains the threshold value for the
cePfePerfCurrent1MinUtilization object. If during the last 1
minute measurement period the cePfePerfCurrent1MinUtilization
object becomes greater than or equal to this t…
Percentager/w
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.1.1.5
cePfePerfConfigThld1MinEfficiency
This object contains the threshold value for the
cePfePerfCurrent1MinEfficiency object. If during the last 1
minute measurement period the cePfePerfCurrent1MinEfficiency
object becomes less than or equal to this thres…
Percentager/w
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.1.1.6
cePfePerfConfigThld5MinUtilization
This object contains the threshold value for the
cePfePerfCurrent5MinUtilization object. If during the last 5
minute measurement period the cePfePerfCurrent5MinUtilization
object becomes greater than or equal to this t…
Percentager/w
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.1.1.7
cePfePerfConfigThld5MinEfficiency
This object contains the threshold value for the
cePfePerfCurrent5MinEfficiency object. If during the last 5
minute measurement period the cePfePerfCurrent5MinEfficiency
object becomes less than or equal to this thres…
Percentager/w
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.1.1.8
.1.3.6.1.4.1.9.9.265.1.1.2 · 1 row entry · 6 columns
This table maintains PFE current running performance, which 
are collected at various measurement periods.
cePfePerfCurrentEntry entry .1.3.6.1.4.1.9.9.265.1.1.2.1
An entry containing performance information applicable to
a particular PFE pipeline.
Indexes
No indexes recorded
Column Syntax OID
cePfePerfCurrentUtilization
This object provides the actual PFE percentage utilization.
It is determined by the number of new work contexts + feedback
contexts divided by total number of contexts that can be
supported by the PFE pipeline.
CurrentUtilization
Textual Convention: CurrentUtilization Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.2.1.1
cePfePerfCurrentEfficiency
This object provides the actual PFE percentage efficiency.
It is determined by the total number of contexts per second
divided by maximum theoretical contexts per second supported
by the PFE pipeline. Under normal co…
CurrentEfficiency
Textual Convention: CurrentEfficiency Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.2.1.2
cePfePerfCurrent1MinUtilization
This object provides the PFE percentage utilization over the
previous 1 minute period. It is determined by the number of new
work contexts + feedback contexts divided by total number of
contexts that can be supported …
CurrentUtilization
Textual Convention: CurrentUtilization Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.2.1.3
cePfePerfCurrent1MinEfficiency
This object provides the PFE percentage efficiency over the
previous 1 minute period. It is determined by the totalnumber
of contexts per second divided by maximum theoretical contexts
per second supported by the PFE p…
CurrentEfficiency
Textual Convention: CurrentEfficiency Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.2.1.4
cePfePerfCurrent5MinUtilization
This object provides the PFE percentage utilization over the
previous 5 minutes period. It is determined by the number of
new work contexts + feedback contexts divided by total number
of contexts that can be supporte…
CurrentUtilization
Textual Convention: CurrentUtilization Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.2.1.5
cePfePerfCurrent5MinEfficiency
This object provides the PFE percentage efficiency over the
previous 5 minutes period. It is determined by the total number
of contexts per second divided by maximum theoretical contexts
per second supported by the PF…
CurrentEfficiency
Textual Convention: CurrentEfficiency Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.2.1.6
.1.3.6.1.4.1.9.9.265.1.1.3 · 1 row entry · 3 columns
This table contains performance statistics for completed 
15 minutes intervals, specifically up to 96 such intervals
over a 24 hours of operation.
cePfePerfIntervalEntry entry .1.3.6.1.4.1.9.9.265.1.1.3.1
An entry containing performance information applicable to
a particular PFE pipeline at a specific interval.
Indexes
ENTITY-MIBentPhysicalIndex cePfePerfIntervalNumber
Column Syntax OID
cePfePerfIntervalNumber
An interval number between 1 and 96, where 1 is the most
recently completed 15 min interval and 96 is the 15 min
interval completed 23 hours and 45 minutes prior to interval
1.
Unsigned32
Constraints:
range: 1-96
.1.3.6.1.4.1.9.9.265.1.1.3.1.1
cePfePerfIntervalUtilization
The percentage of processor utilization by the PFE pipeline
during this completed 15 min interval.
IntervalUtilization
Textual Convention: IntervalUtilization Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.3.1.2
cePfePerfIntervalEfficiency
The percentage of processor efficiency by the PFE pipeline
during this completed 15 min interval. Under normal conditions,
this number will be 100 and when efficiency starts degrading,
it will start going down until it …
IntervalEfficiency
Textual Convention: IntervalEfficiency Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.3.1.3
.1.3.6.1.4.1.9.9.265.1.1.4 · 1 row entry · 2 columns
This table contains the running utilization and efficiency 
of the PFE pipeline for the 24 hour period preceding the 
current interval. If the agent was restarted less than 24
hours ago, i.e., when there are less than 96 intervals in the
cePfePerfIntervalTable, it will contain the running utiliza-
tion and efficiency up to the last collected 15 minute inter-
val.
cePfePerfTotalEntry entry .1.3.6.1.4.1.9.9.265.1.1.4.1
An entry containing performance information applicable to
a particular PFE pipeline at the end of each interval in the
cePfePerfIntervalTable.
Indexes
ENTITY-MIBentPhysicalIndex
Column Syntax OID
cePfePerfTotalUtilization
The running utilization by the PFE pipeline for the prece-
ding 24 hrs.
TotalUtilization
Textual Convention: TotalUtilization Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.4.1.1
cePfePerfTotalEfficiency
The running efficiency by the PFE pipeline for the preceding
24 hrs. Under normal conditions, this number will be 100 and
when efficiency starts degrading, it will start going down
until it reaches zero.
TotalEfficiency
Textual Convention: TotalEfficiency Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.1.4.1.2
.1.3.6.1.4.1.9.9.265.1.2.4 · 1 row entry · 7 columns
This table contains a history of events generated by the 
agent.
cePfeHistEntry entry .1.3.6.1.4.1.9.9.265.1.2.4.1
An entry will exist for each event that has occured while
cePfeHistNotifiesEnable object is set to 'log(2)' or
'logAndNotify(4)'.
Indexes
cePfeHistIndex
Column Syntax OID
cePfeHistIndex
An integer value uniquely identifying the entry in the table.
The value of this object starts at '1' and monotonically
increases for each event condition transition monitored by the
agent. If the value of this object …
Unsigned32
Constraints:
range: 1-4294967295
.1.3.6.1.4.1.9.9.265.1.2.4.1.1
cePfeHistEntPhysIndex
The value in this object is equal to the value of the
entPhysicalIndex, from the Physical Entity Table (RFC 2037),
that is associated with the PFE pipeline that has caused
this event.
ENTITY-MIBPhysicalIndex
Textual Convention: ENTITY-MIBPhysicalIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.9.9.265.1.2.4.1.2
cePfeHistType
This object describes the type of event that has occurred.
HistEventType
Textual Convention: HistEventType Enumeration
Type Values:
1thldUtilizationEvent
2thldEfficiencyEvent
3thld1MinUtilizationEvent
4thld1MinEfficiencyEvent
5thld5MinUtilizationEvent
6thld5MinEfficiencyEvent
7restartEvent
.1.3.6.1.4.1.9.9.265.1.2.4.1.3
cePfeHistThld
The configured value of the specific threshold.
Percentage
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.2.4.1.4
cePfeHistValue
The actual value of the specific performance objects, at the
time of the sample, which is related to the threshold event.
Percentage
Textual Convention: Percentage Unsigned32
Type Constraints:
range: 0..100
.1.3.6.1.4.1.9.9.265.1.2.4.1.5
cePfeHistRestartReason
The reason for which the PFE pipeline has restarted.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.265.1.2.4.1.6
cePfeHistTimeStamp
This object specifies the value of the sysUpTime object at
the time the event was generated.
SNMPv2-TCTimeStamp
Textual Convention: SNMPv2-TCTimeStamp Unsigned32
.1.3.6.1.4.1.9.9.265.1.2.4.1.7